Tender For providing of construction of drain for 2x210 mw ash water recirculation system at ptpp, parichha. - engaging jcb on hire bases including hire fuel driver helper etc. complete. , clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. , demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of material within 50 metres lead as per direction of engineer-in-charge in lime mortar , earth work in excavation by mechanical means (hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. , filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. , providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , "centering and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings, balconies and access platform" , steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.thermo-mechanically treated bars , random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand) , brick work with fly ash (non modular) bricks of class designation 7.5 in foundation and plinth incement mortar 1:6 (1 cement : 6 coarse sand) , 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) , supplying and filling in plinth with jamuna sand under floors, including watering, ramming, consolidating and dressing complete. , "hire charges of pump set of capacity 4000 litres/hour for dewatering which include cost of services of operating staff, cost of lubricating oil, diesel / petrol/ kerosene oil , other consumables for running the plant and machinery. the hire charges of plant machinery on per day basis are for single shift of eight working hours." , providing and laying non pressure np-4 class (heavy duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 900 mm dia rcc pipes.
Tender For tender for supply of airconditioners and other items at gwalior airport -supply of 1.5 tr inverter type , 5 star rating as per latest bee norms , hiwall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensing unit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , supply of 2.0 tr inverter type , 5 star rating as per latest bee norms , hi-wall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensing unit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , installation , testing , commissioning of 2.0/1.5 ton split inverter a/c i/c supply & fixing of iron angle structure stand suitable for outdoor unit , makeup interconnection , top up refrigerent , painting i/c necessary civil works complete as required , providing suitable size pvc pipe for drawing the gas/drain pipe and wire etc through the concrete/brick wall as required. , supply & fixing of extra copper refrigerant piping for suction and delivery line with all accessories suitable for following capacity acs i/c insulation , gas refiling , power & control cabling etc completed as required.of standard gauge for installation of above units as required at site. , supply & fixing of hard pvc drain piping of proper dia for installation of above units as required at site beyond company provided standard length. , supply , installing , testing and commissioning of 5kva voltage stabilizer suitable for 1.5/2.0 tr split ac units on wall including providing connections etc. as required. (model-v guard vgb 500 or equivalent). , sitc of industrial type ro water purifier having capacity minimum 50 lph capacity with uv & membranes , sediment filter , carbon filter , tds control , water level sensor , 3 prefilter (1 carbon candle and 2 micron filter) , auto flush & output water etc as per manufacturers specifications i/c , making inlet and outlet water connections with water cooler complete. suitable for operation on 230 v , single phase , 50 hz ac supply. , supply of water cooler of fully stainless steel body with thermostate cut- off automatic operation having cooling capacity 40 ltr. per hour and storage capacity 80 ltr per hour , working on 220 v , 50 hz , ac supply including automatically controls with temperature , over load protection , water line connection etc. complete as required . , supply of desert air cooler (duct type) with following minimum specifications as given below. fan size - 18 inch & above. fan speed - 1400rpm/ 3 speed. water tank capacity - 110 litres & above - jointless tank. material of cooler body/sump tank - galvanized steel sheet (isi marked to is 277 latest) cooling media - aspen/wood wool. cooling area - 500sqft & above. cooling pads - on 4 sides. , supply of frp wall support ladder of size 12feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp wall support ladder of size 20feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp tiltable telescopic tower ladder of size 32feet meeting specifications as provided in the technical specifications of the agreement of the work. (make - arham/ladd
Tender For corrigendum : providing of design installation and maintenance of educational lab/centre - science lab; equipment supply & installation in concrete & transportation lab in civil department; buyer - flexural test for tiles testing machine , pavement intensity test apparatus
Tender For supply of refer soq item no. 1a. supply of lt power cable of 1.1 kv grade of following size...a. 3.5 x 120 sqmm. , refer soq item no. 1b. supply of lt power cable of 1.1 kv grade of following size...b. 3.5 x 70 sqmm. , refer soq item no. 1c. supply of lt power cable of 1.1 kv grade of following size...c. 4 x 25 sqmm. , refer soq item no. 2a. supply of high-density polyethylene hdpe pipe...a. 40 mm dia , refer soq item no. 2b. supply of high-density polyethylene hdpe pipe...b. 63 mm dia , refer soq item no. 3a. laying of one number pvc insulated and pvc sheathed, xlpe power cable of 1.1 kv grade...a. up to 35 sqmm , refer soq item no. 3b. laying of one number pvc insulated and pvc sheathed, xlpe power cable of 1.1 kv grade...b. above 35sqmm and up to 95 sqmm , refer soq item no. 3c. laying of one number pvc insulated and pvc sheathed, xlpe power cable of 1.1 kv grade...c. above 95 sqmm and up to 185 sqmm , refer soq item no. 4. demolishing cement concrete or bituminous road or paver block roads by manually or mechanical means...as per direction of engineer-in-charge. , refer soq item no. 5. providing and laying in position cement concrete 1-2-4, 1 cement, 2 coarse sand, 4 graded stone aggregate 20 mm nominal size...etc. as required. , refer soq item no. 6a. supply and making end termination with compression brass gland and aluminium lugs...a. 4c x 25 sqmm. , refer soq item no. 6b. supply and making end termination with compression brass gland and aluminium lugs...b. 3.5c x 70 sqmm. , refer soq item no. 6c. supply and making end termination with compression brass gland and aluminium lugs...c. 3.5c x 120 sqmm. , refer soq item no. 7a. providing, laying and fixing following dia g.i. pipe medium class in ground complete...a. 40 mm , refer soq item no. 8. design, manufacture, supply, installation, testing and commissioning of outdoor type double door lt panel....160a 4 pole fp, 35 ka mccb with thermal magnetic release - 3 nos. , refer soq item no. 9. supply, installation, testing and commissioning of weather proof suitable size sub feeder panel..outgoing, 63a 4 pole, 25 ka mccb with thermal magnetic release - 6 nos. , refer soq item no. 10. supply of led street light 45 w 6500 lumens, min. cri greater than or equal to 70...pc cover as per the technical specification. , refer soq item no. 11. supply of 6 mtr high gi octagonal continuously tapered galvanised street light pole...keselec, model-valmont or equivalent. , refer soq item no. 12. erection of metallic pole of item no. 11 in cement concrete...including excavation and refilling etc. as required. , refer soq item no. 13. itc of prewired, outdoor led fittings of all types complete with accessories...complete as required. , refer soq item no. 14. sitc of pre-fabricated outdoor type 3-phase street lighting panel...and brick foundation for erecting the ms frame etc. as required. , refer soq item no. 15a. supplying and laying of following size dwc or hdpe pipe...complete as required. a. 40 mm dia , refer soq item no. 15b. supplying and laying of following size dwc or hdpe pipe...complete as required. b. 63 mm dia , refer soq item no. 16. earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories...with charcoal or coke and salt as required. , refer soq item no. 17. providing, laying and fixing 80 mm dia g.i. pipe, medium class...re-positioning same with pcc. , refer soq item no. 18. providing and fixing 6 swg dia g.i. wire on surface or in recess...as required. //bid details 2 / 23
Tender For laying, jointing and testing of gi pipe 125mm (mg) and 150mm (mg) at various rds, construction of r/wall, construction of b/wall, construction of anchor blocks and providing, laying cement concrete around mbr and repair of trench weir
Tender For corrigendum : all works related to manufacturing, stacking, curing and testing of 21076 nos reinforced cement concrete 500 mm dia 75mm thick anchor blocks as per pspcl specification at pilot workshop sas nagar (mohali). - manufacturing, stacking, curing & testing of 21,076 nos reinforced cement concrete 500 mm dia 75mm thick anchor blocks as per pspcl specification at pilot workshop, sas nagar (mohali) (te no- 04/pwm/2025-26)
Tender For supply, erection, testing and commissioning of 136 m3/ hr. 30000 gph (uk) capacity hscf pump set, total head 50 mtr, with suitable motor 4p/tefc/ie3 horizontal foot mounted type with rating 415v, 50hz, 3 phase along with soft starter panel (with copper bus bar), pump set specifications shall conform to pcee/grc's latest specification and as per annexure a (inclusive of dismantling, making concrete foundation work, supply of suitable size foundation bolts and all requisite materials). spares & accessories of pumpset to be supplied with each set as per clause no. 3 & 4 of pcee/grc%u2019s specification no. cee/s/185/hscf pump/9/98/revised july 2022. location: sonanala pump house under ssee/g/sini. [ warranty period: 30 months after the date of delivery ]