Get complete information related to latest Feasibility Studies Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Feasibility Studies Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Feasibility Studies Tenders.
Tender For preparation of dpr of heritage site monuments site plan conducting of detailed survey rendering of service for providing of architectural structural design of rcc as per indian standard codes of practice and service for standard penetration test as
Tender For rendering of service for providing of structural drawing and design duly vetted by gcet jammu /i.i.t/nit and preparation of detailed estimate/ boq/survey of site, soil testing (03 no minimum) for construction of multipurpose degree college rbn
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For rendering of service for providing of structural drawing and design duly vetted by gcet jammu/i.i.t/diqc jammu/nit and complete job for constt. of pwd guest house with conference hall at ramban under nfb. 3rd call
Tender For rendering of service for providing of structural drawing and design duly vetted by gcet jammu /i.i.t/diqc jammu/nit and complete job for establishment of pre-fab structure for centre for mountaineering and sking at sanasar 2nd call
Tender For rendering of service for providing of structural drawing and design duly vetted by gcet jammu /i.i.t/diqc jammu/nit complete job for khel bhawan-modern sports infrastructure and residential facility at kounsi nallah govindpora maitra ramban
Tender For rendering of service for providing of structural drawing and design duly vetted by gcet jammu /i.i.t/diqc jammu/nit and/ boq/survey of site, soil testing (03 nos minimum) complete job for permanent restorationfoot bridge over banjal nallah nashri
Tender For planning, design, construction, testing and commissioning, certification, validation of biosafety level-3 (bsl-3) laboratory (g plus 1 floor) in epc mode-i under pm-abhim for national centre for disease control (ncdc) at kims, hubballi, karnataka inclusive of (i) obtaining of all local body approvals, eia, consultancy services (architectural, structural & mep), modular pre-fabricated wall panel & pre fabricated ceiling panel, epoxy flooring, doors, drains, water supply piping in bsl-2/3 lab containment area, sanitary installation, internal roads, parking facilitation, ug sump, terrace water tank, water supply lines, storm water drains, external sewerage system, service trenches, demolishing of existing structure, retaining walls, internal electrical installations, fire alarm system, fire fighting system, lifts, sub station, dg sets, ups, air conditioning system (hvac & vrv/vrf), cctv, access control system , ibms, lan, ip based epabx system, audio visual system, boom barriers,subwork/packages:etp equipment and street lighting etc., (ii) design, supply, installation, testing and commissioning of all equipment for bsl-3 & bsl-2 lab. (iii) certification, validation, commissioning of bsl-3 lab facility from third party validation agency. (iv) operation of complete facility for 5 years, annual maintenance during 3 years defect liability period plus 2 years comprehensive maintenance of complete bsl-3 lab facility including all equipment after 3 years dlp including annual validation
Tender For providing of facility management services - lumpsum based - design and planning; preparation of architectural and structural drawing for provn of baggage room for single accn of offrs, jco & ors at nda khadakwasla; consumables to be provided by service provider (..
Tender For corrigendum : consultancy services for the preparation of feasibilitystudies and detailed project report for land acquisition and 2 lane with paved shoulders at ajara and gadhinglaj city bypass of amboli ajara gadhinglaj sankseshwar road nh 548h in the st