Get complete information related to latest Feeder Main Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Feeder Main Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Feeder Main Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; installation of permanent piping system for resin removal and loading from sssb water purification ion exchange column for remote handling of resin in fue..
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; thermal insulation works on 1 x 500 mw steam turbine & associated valves and on power cycle piping & valves; as per tender document
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; e 4171 biennial rate contract for specialized glass piping jobs in cna plant at rcf, trombay unit; as per scope of work
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - piping works for barauni refinery expansion (br-9) project (part-aand part-b).
Tender For tender for replacement of damaged 11 kv vcb for 11 kv birra town feeder of 33/11 kv s/s birra u/n birra d/c & replacement of damaged 11 kv vcb for 11 kv kamrid feeder of 33/11 kv s/s saragaon u/n saragaon d/c & replacement of damaged 33 kv vcb for i/c 33 kv feedermain bus bar of 33/11 kv s/s birra u/n birra d/c. pr.no.- 10071561
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - annual rate contract for misc. mechanical maintenance works (piping, miscellaneous hot and cold jobs) in om&s, offsites and tank farm area at barauni refinery.
Tender For corrigendum : procurement of different types of spares for vibrating feeder of unit-2 overhauling scheduled in august-2026, stage-1(2x300 mw), sgtpp. - procurement of different types of spares for vibrating feeder of unit-2 overhauling scheduled in august-2026, stage-1(2x300 mw), sgtpp., middle groove,4m l for vibrating feeder sgtpp of unit 1 and 2 ( moc: ss-202, thickness 3 mm ), middle groove,5m l for vibrating feeder sgtpp of unit 1 and 2 ( moc: ss-202, thickness 3 mm ), spring,steel,main for vibrating feeder sgtpp ( moc : spring steel. ), clamping sheet,guide plate $for vibrating feeder sgtpp of unit 1 and 2, plate,lower pr plate for vib conv,b&a/88 for mill rejection sgtpp vibrating conveyor, plate,upper pr plate for vib conv,b&a/87 for mill rejection sgtpp vibrating conveyor, bush,guide plate spring,b&a/33 for mill rejection sgtpp vibrating conveyor, plate,spring base guide,b&a/34 $for mill rejection sgtpp vibrating conveyor, vibrating feeder # main spring holding plate to middle groove of vibrating conveyor for unit #1 & 2
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 1 restoration of vessels thickness by metal weld built-up for a thickness of 8mm, which involves removal of paint at repair areas; as per tender con..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 2 restoration of vessels thickness by metal weld built-up for a thickness of 4mm which involves removal of paint at repair areas; as per tender cond..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 3 engaging pressure vessels inspector/ certified third party consultant for works in scope of work; as per tender conditions,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 4 butt and groove fillet welding of nozzles, pad plates, piping and flanges of pressure vessels as detailed in scope of work; as per tender conditio..,repair, maintenance, and installation