Get complete information related to latest Feedthrough Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Feedthrough Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Feedthrough Tenders.
Tender For supply of 6 quad cable 1.4mm dia copper conductor, polythene insulated aluminium screened, wire/strip galvanized steel,armoured, underground, jelly filled as per specification no.rdso/spn/tc/72/2007, amendment no.1 & 2 or latest (inspection : rdso) [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 2 %age , item category : special (signaling cables) , total po value variation permitted: not applicable ] ]
Tender For corrigendum : supply of service connector of 2.5 sq.mm cross section for connecting railway carriage fan and light fittings as per item no.wago make or equivalent as per the technical data: (1) type of wiring: side-entry wiring. (2) total number of connection points: 2. (3) total number of potentials: 1. (4) connection technology: cage clamp. (5) actuation type: push-in. (6) connectable conductor material: copper.(7) solid conductor: 0.5 - 2.5 mm 2/20 - 16awg. (8) fine stranded conductor: 0.5 - 2.5 mm 2/20 - 16awg. (9) strip length: 9 - 11mm/ 0.35 - 0.43 inch. (10) width: 8mm/ 0.315 inch. (11) height: 15.5mm/ 0.61 inch. (12) depth: 42 mm/ 1.654 inch. (13) colour: grey. (14) fire load (mj): 0.099 (mj). (15) weight(g): 5(g). [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of isi marked 11 kv (e) grade 3core 240 sq.mm. ) ht cable stranded compacted circular aluminium conductor screen semi conducting compound xlpe insulated, insulation screening with extruded semiconducting compound in combination with copper tape, cores laid up inner sheath of pvc, galvanized steel flat string armored and overall pvc sheathed cable confirming to is: 7098(part 2):1988 with amendment number 1 and 2 and 3 reaffirmed 2005 & improved fire retardant features as category c2 fr-lsh type. (3) cable is not use for mines & low voltage application. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of e-beam irradiated thin walled flexible elastomeric cross linked cable with copper conductor , size 120 sq.mm, 1.8 kv grade conforming to rdso / spec.no.elrs / spec /elc/ 0019 (rev. 4) feb.2018 for rolling stock application. note:- 1). dealers should attach valid dealership certificate from the oem along with the offer. 2). manufacturers should indicate theiridentification mark, month and year of manufacture at a suitable location by using a suitable method without affecting the performance of the product.3) offers of rdso approved vendors only will be accepted. [warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of single core electron beam irradiated cable with copper conductor of size 0.5 sq. mm, 300 / 500 v ac, confirming to clw specification no. clw/es/3/0458, alt. e. the cable shall be supplied in red and black colour only. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of single core thin walled electron beam irradiated copper cable, size 2.5 sq mm,with copper conductor, working voltage above 750v & up to 1.8/3.0 kv, suitable for use in rolling stock application, as per rdso specification no elrs/spec/elc/0019 (rev-4) of feb- 2018. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For maintenance of point wiring, old unsv fan and geysers, db and light fittings with other connected items in otm and md accn at ghatkopar and vikhroli area under ge (n) santacruz mumbai - supply & fix including taking down sub main wiring with two run of 06 sqmm stranded copper conductor frls wire with one run of 06 sqmm stranded copper conductor as earth continuity conductor connected to common earth dolly including pvc fr heavy duty conduit of adequate size for housing the wires from main db to spn db complete all as specified directed by engr in charge. note: two runs of 06 sqmm cable and one run of 06 sqmm cable with pvc conduit shall be measured as one length. make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for sub main wiring with two single core 04 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty, isi marked of suitable size for sub main wiring including 04 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- two runs of 04 sqmm copper conductor cable, one run of 04 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for three phase sub main wiring with 4 single core 10 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty of adequate size, isi marked, not less than 25 mm dia for sub main wiring including 10 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- four runs of 10 sqmm copper conductor cable, one run of 10 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, frlsh, passing through pvc casing capping/pvc conduit including all fittings and accessories for mounting of switches & sockets as required at site along with one run of pvc insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) frlsh as earth wire connected to earth dolly complete all as specified & as directed by engr-in-charge for one light point/ exhaust/wall/ceiling fan controlled by one switch.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit/ pvc capping-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, all as per item no.4 above but one bell point controlled by one bell push., all as per serial no.4 here-in but for one light point controlled by two way switches (two way switch point wiring), all as per item no.4 but one 3 pin socket point 5 amps on independent board, all as per item no.4 but one 3 pin socket point 5 amps on same board, all as per item no 4 here-in-before but for one socket point 15 amp with 2.5 sq mm pvc unsheathed frlsh wire along with 2.5 sq mm green colour wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed., all as per item no 4 here-in-before but for point wiring on independent board with 4sqmm copper cable and provision of 4sqmm pvc insulated frls cable 1100 volts grade with
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp
Tender For repair/replacement of e/m items and rewiring in md and otm accn at 7a area, 161 mh, asc, mes ib, devkatiya and connected area at mil stn pithioragarh under ge (mes) pithoragarh - description of items, taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and removing material for taking credit (credit for material should be made as per condition sepretly) and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified., taking down switches, socket, ceiling roses, pendants, regulators, sockets, holder, bell, bell push etc any type. all as specified and direct., m&l for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid pvc conduit medium grade size 20 mm dia or higher with all fittings (isi marked) controlled by one switch including ci/ms sunk box for piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified., m&l for point wiring for one light point controlled by two way switches with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid pvc conduit medium grade size 20 mm dia or higher with all fittings (isi marked) controlled by one switch including ci/ms sunk box for piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified., all as per srl item no-2 here in above but point wiring in replacement for one 3 pin 5/15 amps socket outlet independent with 2.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 2.5 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit., all as per srl item no-2 here in above but point wiring in replacement for one 3 pin 15 amps socket outlet independent with 4 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 4 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit., all as per srl item no-2 here in above but point wiring in replacement for for one 5a socket outlet on the same board with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch, m&l for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm pvc insulated unsheathed copper conductor single core multi strand flexible cable frls with proper color coding and 1.5 sqmm pvc insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in pvc casing & caping of size width 25 mm x hight 16 mm or higher with all fitting