Web Analytics Made Easy - StatCounter

Feedthrough Tenders

Get complete information related to latest Feedthrough Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Feedthrough Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Feedthrough Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45065144 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of pvc insulated unsheathed cable with flexible conductor isi marked to is 694

Central Government And Public Sector

CTN :45056675 Due date: 07 May, 202607 May, 2026 NA
Tender For supply and testing of 2 core 10 sq.mm lt power cable , aluminum balance stranded conductor , xlpe insulated, cores laid up ,pvc inner sheathed , armoured (galvanized steel strip) extruded pvc type st2 outer sheathed , 650/1100v grade as per is 7098(part1) 1988 with up to date amendments. make-havells, polycab, kei [ warranty period: 30 months after the date of delivery ]

Central Government And Public Sector

CTN :45056676 Due date: 07 May, 202607 May, 2026 NA
Tender For supply of 1 core 240 sq.mm lt power cable, aluminum balance stranded conductor, xlpe insulated, armoured (galvanized steel strip ) extruded pvc type st2 outer sheathed 650/11000v grade as per is 7098(part1) 1988 with up to date amendments . make :havells , kei, polycab [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :45063536 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of low smoke halogen free profibus cable, 150 ohm nominal impedance for oil rig application as per bhel,low smoke halogen free profibus cable, 150 ohm nominal impedance for oil rig application as per bhel,10c x14 awg (1.94 sqmm) multi conductor control cable with cross linked polyolefin insulated, armore,10c x14 awg (1.94 sqmm) multi conductor control cable with cross linked polyolefin insulated, armore

Central Government/Public Sector

CTN :45063680 Due date: 21 May, 202621 May, 2026 NA
Tender For supply of 7 core x 2.5 sq. mm copper conductor armoured pvc insulated pvc sheathed contorl cable 650 voltage gr,7 core x 2.5 sq. mm copper conductor armoured pvc insulated pvc sheathed contorl cable 650 voltage gr,4 core x 6 sq. mm. pvc copper flexible cable 1.1kv grade,4 core x 6 sq. mm. pvc copper flexible cable 1.1kv grade

Central Government/Public Sector

CTN :42424475 Due date: 04 May, 202604 May, 2026 NA
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia

Central Government / Public Sector

CTN :45012869 Due date: 18 May, 202618 May, 2026 NA
Tender For supply of pvc insulated armoured unscreened underground railway signalling power cable aluminium conductor as per rdso specification no irs:s63/2014 rev 4.0 and is:1554 part-i. size:-2 core x 70 sq mm. [ warranty period: 30 months after the date of delivery ]

Central Government And Public Sector

CTN :45065252 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of pvc insulated copper cable single core and multi core circular sheathed with rigid conductor (v2) isi marked to is 694

corporations/Associations/Others

CTN :45065293 Due date: 12 May, 202612 May, 2026 NA
Tender For supply of pvc insulated copper cable single core and multi core circular sheathed with flexible conductor (v2) isi marked to is 694

State Government

CTN :44721131 Due date: 04 May, 202604 May, 2026 NA
Tender For bid to ras supply of electrical - single core copper conductor cable , insulated copper wire , armoured electrical cable , modular switch , 3 pin top , 3 pin to , fan regulator , mcb , ceiling fan , led batten , led bulb , batten holder , bed switch , led flood light , recess mounting led round down light
 Loading, Please wait...

Connect us via What's Up