Get complete information related to latest Female Adapter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Female Adapter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Female Adapter Tenders.
Tender For supply of auxiliary contactor for pantograph and vcb [pos no.130.1, 136.4] clw spec no.clw/es/3/0040, alt-a. item type ref.lc1d09fd, make: schneider electric. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 3/4" x 30" bogie hose connection assly for electric locos conforming to clw drg no. 0/3/65/106 alt-9. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, installation & commissioning of pressure switch, part no. 88290003-806 & microprocessor controller part no. 88292036-888, make - hitachi sullair genuine parts. for sullair electric screw air compressor, cap.-500 cfm, model-ls20-125hh (air cooled), qty. - 01 no. each item in set. [ warranty period: 6 months after the date of delivery ] ]
Tender For supply of push button reset vigilance control (bpvr)as per clw spec no. clwes/3/0072/ type ref. zb4bp587 + zb4bz101, make: schneider electric only. note: firm should submit authorised dealership certificate along with tender otherwise offer will not be considered. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of corridor light 4 feet 17 watts +_ 10% led version of old 110 dc 4feet tube light fitting made of min. 1mm thick m.s or g.i fabricated and powder coated sheet . as per new spec.no. clw/es/3/0672 rev.1 and drawing no.clw/es/3/sk-1/0672 for replacement of old spec.no. clw/es/3/0041 in 3 phase electric loco .fixtures do not required any alteration in loco led shall be of any brand already approved by clw in spec. diffuser shall be of 1.5mm thick fire retardant polycarbonate cover with m.s/g.i sheet, powder coated caps on both sides. note: 1) this item is reserved for clw approved sources only as per vendors directory id: 2100755 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of spare parts of led for conversion of 110 vdc-2 feet led tube light fitting as per new clw spec.no.clw/es/3/0672 rev.1 & drawing no. :clw/es/3/sk-1/0041 or latest in to 9 watt led light (+ -10% tolerance) for replacement in the existing tube fixture in 3 phase electric lcomotives, retrofittable in the exiting tube fixture design as per above specification number without any alteration in mounting arrangement ofloco. led pcb driver and wago connectors fitted on a min. 0.9 mm thick ms sheet. note: this item isreserved for clw approved sources only as per vendors directory id: 2100755. [ warranty period: 72 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of fire retardant neoprene rubber sheet for cable trenches in electric locomotives of thickness 1.5 mm +/- 0.2 mm & width 1000 mm, to clw spec. no. clw/es/r-24/d or latest. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee