Web Analytics Made Easy - StatCounter

Fence Wire Tenders

Get complete information related to latest Fence Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fence Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fence Wire Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42422994 Due date: 14 Nov, 202514 Nov, 2025 27.12 Lacs
Tender For supply of supply of digital multimeter,supply of insulation resistance,supply of earth meter,supply of digital clamp meters,supply of hand held petrol driven brush cutter machine with accessories,supply of generator honda,supply of portable insulation tester with rechargeable battery,supply of cordless wrench machine,supply of heavy duty electric air blower,supply of advanced tool kit 16 piece,supply of 110 piece multi tool kit,supply of hdmi cable tester,supply of lan cable tester,supply of industrial grade laptop.,supply of digital cable scanner,supply of power and hand tool kit,supply of traceable duct rodder complete with accessories,supply of portable digital light lux meter.,supply of lcd display digital screwguage outside micrometer,supply of lcd display digital vernier caliper,supply of handheld digital hygrometer,supply of cable route locator of 12w high power pipe and cable,supply of non contact voltage detector pen type,sitc and transportation of heavy duty aluminium tiltable tower 50 feet ladder,supply of h

Central Government And Public Sector

CTN :42433002 Due date: 06 Nov, 202506 Nov, 2025 NA
Tender For supply of earth returning cable assembly for axle box of three phase locomotives

CTN :42109768 Due date: 01 Nov, 202501 Nov, 2025 NA
Tender For corrigendum : supply of equipments or accessories required for communicattion division : : - digital earth resistance meter , acbydc clamp meter , cordless telephone instrument 1 plus 1 , cat 6 utp cable 305 meters bundle , telephone line cord 90 meter bundle , handset cord black , handset cord white , telephone rosette box , 10 pair insulation displacement module , rj 11 connector box , rj 9 connector box , rj 45 connector box

CTN :42408904 Due date: 06 Nov, 202506 Nov, 2025 NA
Tender For supply of consumables for p and h 2300 xpa lr shovel c c > f> f---capscrew, part no. - 0826v041 , earth fault relay, part no. - v97822831046 , cable joint kit, part no. - 3x25sqmm , t handle, part no. - a1152 , connecting strap, part no. - 9579e71f1 , tong tester, part no. - 89z367

CTN :42432261 Due date: 04 Nov, 202504 Nov, 2025 2.35 Lacs
Tender For cable termination of 11kv vcb at main 11kvsubstation and trees trimming and earth pit in different location for 550v, 415v overhead line at kora para of bankola colliery

CTN :42352514 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For repair and maint of ht cable 185 sqmm and acsr overhead conductor including connected items - supply laying testing and commissioning ug cable , supply and fix triple pole gand operated devic , material and labour for cable jointing kit , sand cushioning 8 cm before laying ht lt underground cable , unreinforced precast concrete cable cover , pin type porcelain vitreous white brown , disc type insulator porcelain vitreous , acsr conductor of size mink complete , material and labour for earth continuity conductor , excavating in trenches in hard dense soft soil , removing excavated material to a distance , returing filling in including spreading levelling watering

CTN :41553715 Due date: 25 Oct, 202525 Oct, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of upgradation of central substation for es dept at grse main works d d - supply of upgradation of central substation for es dept at grse main works d d - ht copper bus bar , vcbs items , wti,buchholz, oti relays , 3 core x 300 sq. mm. aluminium conductor , pvc hume pipe , new two - 02 nos transformers , 11 kv - e 3 c x 300 sq mm frls xlpe , earth pit item 50 mm dia gi pipe , copper earth plate for neutral earthing , 50 x 6 mm cu flat , 50 x 6 mm gi flat , 2 v 100 ah ni-cd battery , 110 v dc rectifier , buchholz, wti, oti relays for 1k kva transformer , hv cable route marker , mapping of existing cable and pipe lines , civil work for preparation of renovation , position of 06 vcb racks , ht copper bus bar , installation and proving of wti, buchholz, , repair of vcb enclosures , 3 core x 300 sq. mm. aluminum conductor , trench cutting for cable laying , charge for laying of hume pipe , removal of 02 nos. transformer - 1000 kva and position of 02 nos. new transformer , ht cables , earth pit connection , installation of batteries , removal of existing ht panel. , service for removal of existing panel , service for fitment and proving of buchholz, wti, oti relays for 1000 kva transformer , cea approval for new vcb panel and ht cable installations ) /bid number : gem/2025/b/6602235 * /dated: 23-08-2025 & & / bid document 1 / 40

CTN :42360039 Due date: 27 Oct, 202527 Oct, 2025 NA
Tender For supply of power generator - dg set (up to 900 kva) , xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) , material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm , disconnection of existing unserviceable 40 kva and 70 kva dg set mechanically and electrically

Central Government/Public Sector

CTN :42424501 Due date: 08 Nov, 202508 Nov, 2025 11.48 Lacs
Tender For supply of isolator 3 point 3 kv 400 a complete flp vcb 018 , moving contact for isolator 03 sets for 03 phase flp vcb 019 , fixed contact for isolator 03 sets for 03 phase flp vcb 020 , earth leakage relay flp vcb 024 , diode based rectifier complete flp vcb 029 , epoxy resin moulded 1 phase p t 3 point 3kv 110v 150va flp vcb 034 , pt fuse 3 point 3 kv flp vcb 035 , 72 sq mm ammeter ct operated fpl vcb 036 , 72 sq mm voltmeter 0 5kv ptr 3 point 3 kv 110v fpl vcb 037 , h t hex bolt for main lid and terminal ch size m 10 x 25 fpl vcb 054 , h t hex bolt for terminal chamber cover size m 8 x 20 flp vcb 055 , h t hex bolt for cable box size m 10 x 20 flp vcb 056 , dmc moulded auxiliary terminal flp vcb 046 , h t hex bolt for main lid and isolator lid size m 10 x 30 flp vcb 053 , led lamp holder with lamp flp vcb 043 , limit switch fpl vcb 040 , micro switch for push button element flp vcb 039 , auxiliary contactor 3 no 1 nc 110v coil flp vcb 028 , auxiliary transformer for control circuit flp vcb 023 , coil for shunt trip spring release fpl vcb 017 , shunt trip assembly with coil flp vcb 004 , auxiliary switch for vcb flp vcb 013 , vacuum interrupter 400a flp vcb 006 , epoxy moulded core balance transformer 3 point 3 kv flp vcb 025 , jones plug 18 pins flp vcb 044 , brass gland complete with stud and nut flp vcb 052 , solid state o l and s c r with time delay flp vcb 026 , under voltage relay with time delay fpl vcb 027 , 3 pole magnetic overload relay flp vcb 026a , solenoid operated spring release assembly with coil flp vcb 005 , epoxy cast drive insulator for vi flp vcb 011 , dash pot oil for o l relay 50 ml flp vcb 059 , hrc fuse base 20a for control flp vcb 030

Central Government/Public Sector

CTN :42424475 Due date: 05 Nov, 202505 Nov, 2025 NA
Tender For supply of item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall diameter (mm) /- 2.0 15 max. safe pulling tension lo
 Loading, Please wait...

Connect us via What's Up