Tender For supply of supply installation testing and commissioning of high mast tower at bpcl kanpur depot d d - supply and installation of high mast tower as per boq in atc document , supply and installation of high mast luminaire as per boq in atc document , supply and layingcable 3.5c x 35 sq mm as per boq in atc document , constructing gi earth pit as per boq in atc document , supply and laying earth strip as per boq in atc document , supply and laying perforated cable tray 100 mm as per boq in atc document , cable glanding and termination as per boq in atc document , earth excavation upto depth of 1.5 m as per boq in atc document , earth excavation for depth greater than 1.5 m and less than 3 m as per boq in atc document , pcc 1-2-4 as per boq in atc document , earth filling as per boq in atc document , rcc 1-1.5-3 upto plinth level as per boq in atc document , rcc 1-1.5-3 above plinth level as per boq in atc document , supply and laying reinforcement steel as per boq in atc document , supply and welding of ms structure as per boq in atc document
Tender For supply of supply and installation of high mast tower as per boq in atc document , supply and installation of high mast luminaire as per boq in atc document , supply and layingcable 3.5c x 35 sq mm as per boq in atc document , constructing gi earth pit as per boq in atc document , supply and laying earth strip as per boq in atc document , supply and laying perforated cable tray 100 mm as per boq in atc document , cable glanding and termination as per boq in atc document , earth excavation upto depth of 1.5 m as per boq in atc document , earth excavation for depth greater than 1.5 m and less than 3 m as per boq in atc document , pcc 1-2-4 as per boq in atc document , earth filling as per boq in atc document , rcc 1-1.5-3 upto plinth level as per boq in atc document , rcc 1-1.5-3 above plinth level as per boq in atc document , supply and laying reinforcement steel as per boq in atc document , supply and welding of ms structure as per boq in atc document
Tender For supply of 3tr single circuit 1 or 3 phase ductable ac units c c - 3 tr single circuit 1 or 3 phase , itc of 1.5 or 3.0 tr dac unit , 40 x 40 x 5 mm ms angle iron , 40 x 5 mm ms flat strip , upvc pipe 40mm dia , upvc pipe 25 mm dia , 5c x 4 sqmm pvc cu cable , 3c x 1.5 sqmm pvc cu cable , 4c x 6 sqmm pvc cu cable , dp 25 or 32a 230v c mcb in encl , fp 25 or 32a 415v c mcb in encl , gss sheet ducting 0.63mm , gss sheet ducting 0.80mm , supply air grills , 100x50x1.6 mm thick cable tray , 150x50x1.6 mm thick cable tray
Tender For corrigendum : supply of dc lead acid or ni cd batteries for ntpc lara project - 220v lead acid or ni cd battery suitable for main plant , electrolyte for first filling plus 10percent extra in nonreturnable container , wooden racks , stand insulators , intercell, inter row, inter bank connectors , cell numbering tags with fixing arrangement 1set , anti-splash type vent plug , nickle coated connection hardware plus 5percent extra , cable clamps with fixing hardware , pvc or cfrp spill trays under battery set battery to have spill tray covering every cell , battery trolley for entire project , hydrometer , cell testing digital voltmeter 3-0-3v with testing leads , wall mounting type holder for hydrometer and thermometer , set of hydrometer syringes suitable for vent holes in different cells , thermometer for measuring electrolyte temperature , specific gravity correction chart for lead acid battery only , rubber apron , pair of rubber hand gloves , set of spanners , no smoking notice , goggles industrial , instruction card , minimum and maximum temperature indicator for each battery room , acid or alkali mixing jar , battery health monitoring system for each battey cell of battery sets as per sl.no. a.1.1 above , 220v lead acid or ni cd battery suitable for offsite area , electrolyte for first filling plus 10percent extra , ms racks properly treated with alkali resistance powder , stand insulators plus 5percent extra , intercell inter row inter bank connectors , e and c spares for battery 1 and 2 gloves , e and c spares for battery 1 and 2 vent plugs , e and c spares for battery 1 and 2 intercell connectors , supervision of erection -battery -mandays , supervision of erection -battery -visit , supervision of commissioning -battery -mandays , supervision of commissioning -battery -visit , supervision of commissioning -bhms -mandays , supervision of commissioning -bhms -visit , mandatory spares for battery 1 complete dry cell , mandatory spares for battery 1 inter-cell connectors with hardware , mandatory spares for battery 1 bhms spares , mandatory spares for battery 2 complete dry cell , mandatory spares for battery 2 inter-cell connectors with hardware
Tender For shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying of 0.63mm thick gss sheet , supplying of 0.80mm thick gss sheet , supplying of 1.00mm thick gss sheet , sitc of gi volume control damper , supplying and fixing of powder coated extruded aluminium return air grills with louvers , supplying and fixing of 4x16 sqmm power cable , supplying and fixing of control cable of 3x2,5sqmm , sitc of 40mm upvc pipe , sitc of 20mm upvc pipe , sitc ms cable tray 100mm width x 50mm x 1.6mm thickness , sitc ms cable tray 150mm width x 50mm x 1.6mm thickness , sitc of gi strip for loop earthing , dismantling and removing the existing laid old power or control cables , dismantling the existing old package units , recovering the existing laid refrigerant piping of old defective , dismantling the existing old ducts of package units , transportation of the existing fitted old dissmantled package a.c. units , itc of 7 tr sensible high precision ac package unit , supplying and charging of the referigerant gas r-407 , supply and fixing liquid line filter drier , supply and fixing of size 1-1 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 7 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 5 by 8 inch and 18 gauge copper referigerant pipe , laying of 1-1 by 8 inch recovered copper referigent pipe , laying of 7 by 8 inch recovered copper referigent pipe , laying of 5 by 8 inch recovered copper referigent pipe , providing ms structure for outdoor or indoor units , itc of 100mm width x 50mm x 1.6mm , itc of 150mm width x 50mm x 1.6mm , itc of old recovered 4x10 sqmm cable , itc of old recovered 4x1.5 sqmm cable , laying of existing 25 mm x 5 mm thick g.i. strip