Get complete information related to latest Filter Funnel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Filter Funnel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Filter Funnel Tenders.
Tender For supply of flat bottom flask , rubber stopper , pipette bulb , rubber tubing , brush beaker , brush semi micro test tubes , single layered syringe filters diameter 25mm , silicon tube , brush bottle , brush test tube , syringe filter , beaker 250 ml , reagent bottle wide mouth , pipette 20 ml , pipette 10 ml , spare extractor for soxhlet apparatus , condenser allign , beaker 5 ml , test tube graduated 20 ml , beaker 100 ml , beaker 150 ml , measuring cylinder 10 ml , measuring cylinder 100 ml , pipette 5 ml , standard flask 100 ml , flat bottom flask 1000ml , pipette 1 ml , separating funnel with i c polypropylene stopper squibb shape 250ml , separating funnel with i c polypropylene stopper squibb shape 500ml , separating funnel with i c polypropylene stopper squibb shape 1000ml , burette 25 ml , burette 50 ml , pipettes graduated mohr type 1 ml , pipettes graduated mohr type 1 ml nabl , volumetric flask 10 ml , volumetric flask 25 ml , measuring cylinder 250 ml , receiver delivery adapter short stem 19 26 , beaker low form 10 ml , beaker low form 25 ml , beaker low form 50 ml , beaker low form 100 ml , beaker low form 150 ml , flask flat bottom single neck 1000 ml 24 29 , filterfunnel plain long stem 65 mm , filterfunnel plain long stem 100 mm , test tube with joint and stopper graduated 20 ml
Tender For supply , fabrication, galvanizing & erection of steel structure & equipments, ab switches provision of earthing arrangements, providing bus bars, jumpers and droppers, laying of control cables and end termination for enhancement of existing power transformer 110/11 kv capacity from 1x16 mva into 2x16 mva at chendur 110/ 33-11 kv ss.
Tender For supply of 3 ton hyd pallet truck , fuel filterfunnel , black checkered electrical insulation rubber mat , 12 24 volt led work light , mcb for fip test bench
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status