Get complete information related to latest Filter Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Filter Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Filter Wire Tenders.
Tender For corrigendum : supply of consumables for construction of hybrid energy device - mild steel sheet, 8ft x 4ft x 1.2 mm, mild steel angle rod, 1.5 inch x 20 ft, mild steel angle rod, 1 inch x 20 ft, mild steel welding rod, diameter: 3.15 mm, mild steel perforated sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 perforated sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 pipe, 1.5 inch dia, 1.5 inch dia, 1.2 mm, 20 ft, zinc alloy door handle lock, stainless steel 304 welding rod, 2.5 mm diameter, ceramic fibre blanket insulation, 24"x12"x1", ceramic fibre rope, 10 mm diameter, 30 m length, heat insulating gasket, 8 ft x 4 ft, 5mm thickness, heat resistant spray paint 225 ml, silicon pipe 1/2 inch inner dia, 10 m, high temperature silicon hose pipe, 2 inch inner dia, 12 feet, worm-drive tubing clamps, chrome steel, hose clamp, 1/2 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 1 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 2 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 3 inch dia, galvanized mild steel set of nut, bolt and washer, 8 mm, diameter, 2 inch length temperature sensor with digital display, k type, 0-1250 c, adruino uno r3 development board, rod heater, 8.2 mm diameter, 12 inch length, quartz furnace observation glass, temperature: 1200 °c, 10 cm diameter, 5 mm thickness, copper tube 1/2 inch dia, 23 swg, copper electric wire 6 sq. mm, 90 m., copper electric wire 2.5 sq. mm, 90 m, mcb dp 32 a, electric socket 16 a, electric plug 16 a, combined box 20 a, anabond gasket maker 85 g, heavy load caster swivel diameter: 100 mm, galvanized iron pipe b class diameter: 1.5 inch, length: 40 ft, galvanized iron pipe b class diameter: 1/2 inch, length: 20, galvanized iron pipe b class diameter: 3/4 inch, length: 20, stainless steel 304 ball valve diameter: 1.5 inch., stainless steel 304 ball valve diameter: 3/4 inch, stainless steel 304 ball valve diameter: 1/2 inch, check valve, brass diameter: 1.5 inch, check valve, brass diameter: 3/4 inch, check valve, brass diameter: 12 inch, metal cutter grinder disc, pack of 10, grit number 220 diameter: 4 inch, grit material. aluminium oxide, metal cutter grinding wheel, pack of 5, grit number 4,, diameter: 4 inch, grit material: aluminium oxide, flap disc, pack of 10, grit number 80, diameter: 4 inch, grit material: aluminium oxide, flexible heavy duty 3 layer pvc water pipe, diameter: inch, length: 30 m, teflon tape for plumbing, pack of 10, 12 mm thick and 10 m length, heat resestant gloves, material. leather, size: 30.48 cm, nitrile disposable hand gloves, pack of 50 pieces, size l, 150 microfarad capacitor, 230 v, 150 microfarad, 230 v, anti vibration rubber ribbed pads, pack of 4, 150mm x 150mm x 12mm, square pillow block bearing ucf204, 20 mm diameter, inner ball mounted pillow block insert bearing kp08, 8 mm bore, step down transformer, 220v ac to 12-0-12 v,1.5a, single strand wire, diameter 0.51mm,5m, moc3021 moc 3021 optocoupler, hta16-600b triac, 600v 16a, switch, sw-spst, in4007 diode, 100kv ia, bldc motor with compatible e-bike, controller, 48v 900w 3300rpm, lithium-ion battery, a grade 3.2v 2000mah (5c), battery management system, li-ion 135 48v 20a, nickel strip, 0.2 mm thickness, 10 mm width, 5 in length., silicon wire, 12awg, insulation paper, 65mm, glue gun, 40 w, spot welding rod 5000 w, cpu fan 12 v dc, thermoelectric generator (teg), 150°c, module configuration: sp1848-27145, tungsten rhenium thermocouple, minimum temperature reading: 0°c, maximum temperature reading: between 2300°c and 2871°c, max31856 instrumentation amplifier, resolution: 0.0078125°c, supply voltage: 3.3v to 5v, arduino uno r3 with adapter cable, miniature circuit breaker fuse, d type, 32 a, power rocker switch, voltage rating: 24 vdc, current rating: 14 ma, 19mm size red power symbol led s.s. momentary type push button switch 5v-24v dc, potentiometers 100 k. ohm, potentiometers 1 m ohm, relay module-(ssr-2 chann
Tender For supply of screened armoured control cable , instrumentation cable 8pair , instrumentation cable 12pair , control cable 1point 1 kv 4pair , cable 16pair x point 5sq mm armoured individually , 4 pairx1point 5 sqmm type g pair and overall shield
Tender For bid to ras corrigendum : providing of custom bid for services -custom bid for services - services day-to-day maint instrumentation jobs- 1 dropping of pg/tg dropping of bourdon tube type/ diaphragm seal screwed type pressure gauges with or without syphons, temperature gauge without capillary. job scope includes cleaning of mounting surfaces / instruments as required. the scope includes transportation from site to designated location eac 2 fixing of pg/tg fixing of bourdon tube type/ diaphragm seal screwed type pressure gauges with or without syphons, temperature gauge without capillary including clamping on supports, if any. job scope includes cleaning of mounting surfaces / instruments as required. the scope includes transportation from warehouse/shop to site eac 3 dropping of rs pg/tg dropping of remote seal type pressure gauge, panel mounted temperature gauge upto flange rating of 3" 600# rating including dropping of dressing and clamping of capillary tube in the cable trays and on supports. agency shall safegaurd the capillary flange sensor surface while dropping/transportation. job scope includes cleaning of mounting surfaces / instruments as required. including dropping of canopy, if any. the scope includes transportation from site to designated location eac 4 fixing of rs pg/tg fixing of remote seal type pressure gauge, panel mounted temperature gauge upto flange rating of 3" 600# rating including laying, dressing and clamping of capillary tube in the cable trays and on supports. agency shall safegaurd the capillary flange sensor surface while fixing/transportation. job scope includes cleaning of mounting surfaces / instruments as required. the scope includes transportation from warehouse/shop to site eac attachment-5: detailed line description 5 dropping of panel gauge dropping of flush mounted panel pg and draft pgs including process connections. job scope includes cleaning of mounting surfaces/instruments as required. the scope includes transportation from site to designated location eac 6 fixing of panel gauge fixing of flush mounted panel pg and draft pgs including process connections. job scope includes cleaning of mounting surfaces/instruments as required. the scope includes transportation from warehouse/shop to site eac 7 dropping of pt/ps dropping of pressure transmitter/switches by disconnecting the process connections and clamps . job scope includes dropping , de-glanding of cables, and cleaning of mounting surfaces , instruments as required. the scope includes transportation from site to designated location eac 8 fixing of pt/ps fixing of pressure transmitter/switches and connecting the process connections and providing the clamps . job scope includes tubing connections, glanding of cables, fixing of canopy and cleaning of mounting surfaces, instruments as required. the scope includes transportation from warehouse/shop to site eac 9 dropping of rs pt/ps dropping of remote seal capillary type pressure transmitter/switches upto 3" 600# including the dropping of drain/vent lines, capillary tubing from the cable trays. agency shall safegaurd the capillary flange sensor surface while dropping/transportation. job scope includes cleaning of mounting surfaces / instruments as required. including dropping of canopy, if any. the scope includes transportation from site to designated location eac 10 fixing of rs pt/ps fixing of remote seal capillary type pressure transmitter/switches upto 3" 600# including the fixing of drain/vent lines, capillary tubing laying, dressing and clamping in the cable trays. agency shall safegaurd the capillary flange sensor surface while fixing/transportation. job scope includes cleaning of mounting surfaces / instruments as required. the scope includes transportation from warehouse/shop to site eac 11 dropping of dp gauges dropping of differential pressure gauges including panel mounted and dropping of process connections. job scope includes cleaning of mounting surfaces/instruments as req
Tender For corrigendum : tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentation cables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables