Tender For supply of constant voltage constant current battery charger of the following specification: (i) input voltage - 230 v ac (+/-10%), (ii) output voltage 0 to 16 v dc (iii) output current 0 to 10 a, (iv) 3 digit digital panel meter for voltage and current, (v) short circuit protection, (vi) over voltage protection (vii) over voltage protection similar to teklab model no. lh tl 1610s. makes: teklab, aplab, testronix only accepted [ warranty period: 12 months after the date of delivery ]
Tender For tender for supply of sitc and maintenance of addressable firealarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop firealarmcontrolpanel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. firealarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the firepanel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of firepanel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the firealarmcontrolpanels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For corrigendum : supply of eil d d - e4953196 numerical relays 01-sg4950387111-numerical o_slash_c and e_slash_f relay for incomer_slash_tie_slash_bc as per annexure-a it-001 _50_slash_51_slash_50n_slash_51n_slash_25_ , 02- sg4950387120-numerical trafo protection relay as per annexure-a it-002 _50_slash_51_slash_50n_slash_51n_. , 03-sg4950387138- numerical o_slash_c and e_slash_f relay for capacitor feeder_slash_og as per annexure-a it-003. , 04- sg4950387146-numerical motor protection relay as per annexure-a it-004. , 05-sg4950387154-numerical motor differential _slash_ ref. protection relay as per annexure-a it-005 , 06-sg4950387162-numerical line diff relay as per ann-a it-006 , 07-sg4950387170- numerical motor protection relay with reverse power function as per annexure-a it-007. , 08- sg4950387189-numerical under voltage relay as per annexure-a it-008. , 09-sg4950387219-ethernet switches _24 cu plus 4 fo_ as per ann-a it-009. , 10- sg4950387227-cat-6 cable as per ann-a it-010. uom- meters , 11-sg4950387235-fo cable as per ann-a it-011. uom-meters , 12-sg4950387243-data concentrator panel as per ann-a it-012. , 13-sg4950387251-human machine interface _hmi_as per ann-a it-013. , 14- sg4950387278-relay parameterization device for dc as per ann-a it-014. , 15-sg4950387286-global positioning device as per ann-a it-015. , 16- sg4950387294-report printing device as per ann-a it- 016. ) /bid number : gem/2026/b/7405586 * /dated: 31-03-2026 & & / bid document 1 / 18
Tender For supply of dc sol valve pn vp78s3 for cvt strap m c , dc sol valve pn vp78d3 for cvt strap m c , dc sol valve pn sy9140 for cvt strap m c , air filter pn 610f for strap cvt m410-an , flow control valve pn as5000- 02 cvt m410 , flow control valve pn as5000-04 cvt m410 , cylinder head cap screw m10x30 cvt m410 , cylinder heat protection guard cvt m410 , head tilting cylinder pn c0514 15-16 cvt , head forward reverse cyl -q15h 1107 cvt , cylinder b50-1800 sig516-v-01-58 cvtm410 , pneumatic accessories pn q15h 1099 cvt , pneumatic fittings strapng head side cvt , pneumatic fittings head forward cvt m410 , pneumatic fittings head reverse cvt m410 , pneumatic fittings panel side cvt-m410 , heat proof pn pipe strapng head side cvt , heat proof pn pipes head forward cvt-410 , heat proof pn pipes head reverse cvtm410 ) /bid number : gem/2026/b/7463183 * /dated: 06-05-2026 & & / bid document 1 / 23
Tender For providing of repair and overhauling service - repair refurbishment of focon intercom system controlpanel of corrosion protection system cathodic system and rms radiation monitoring system onboard in submarine; any other suitable brand; no; buyer premises
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply of power distribution panel 400a, 415v. the panel indoor type floor mounted and free standing designed for ip-4x ingress protection, made of crca sheet steel. , supply only pf correction panel with svg 430kvar. 415v panel indoor floor mounted, free standing with ip-31 degree of ingress protection made of crca sheet steel , material and labour for pvc insulated, lt unarmoured sheathed frlsh electric sense cable with copper multistanded conductor 1100 volts grade, cross-sectional area 4 sqmm, 6 core , material and labour for chemical earthing complete with copper bonded 250 micron electrode 1500mm long and 25 mm dia , materal and labour for earthing complete with gl earth plate 600mmx600mmx6mm thick electrode buried directly in ground vertically to a depth not less than 2.25 meter , material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 20x3mm galvanised iron or steel wire , material and labour for earth continuity conductor drawn through conduit by pipe or fixed to pole or any other indicated situation for loop earthing 32x6mm galvanised iron strip , supply and fixing 40 mm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , material and labour for rcc 1-2-4 type b-1, using 20 mm graded stone aggregate as in foundation, including rafts, footing, foundation beams, , material and labour for steel reinforcement for concrete with ms tmt bar 10mm dia and over cut to length, bend to shape required including cranking, bending, , warranty service amc by cmc including breakdown service for 5 years to ensure the safe, reliable, and efficient operation of the electrical panel ) /bid number : gem/2026/b/7493324 * /dated: 08-05-2026 & & / bid document 1 / 17
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , supply, installing, testing and commissioning of pdb panel 800a, 415v. the panel shall be indoor wall mounted. it shall be completely made of crca sheet steel. , supply, installing, testing and commissioning of pf correction panel with rms 430kvar, 415v. panel indoor floor mounted, free standing with ip-31 degree of ip made of crca sheet steel. , material and labour for xlpe insulated, lt armoured electric sense cable with aluminiur star ded conductor 1100 volts grade, cross- sectional area 4 sqmm, 6 core , m and l for brick sub class b 250mm x 115mm x 0.75mm and laid in trenches as in protection of ug cabe complete all as specified and directed , supply and filling in and spreading unwashed river sand for cushioning and covering the uncer ground cables in trenches and punning to provide required cover , excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying cif cables, pipe lines, protection pipes , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , remnoving excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed , material and labour for earthing complete with copper plate electrode 600mmx 600mmx. 3.1.5 mm thick buriel directely in ground vertically , supply and fixing 25 sqmm interconnecting pvc pipe sets and pipe fittings along with suitable accessories complete all as specified and directed , civil work rcc panel base slab size - 2000mm l x 1300mm w x 150mm thickness , warranty service amc by cmc including breakdown service for 1 year to ensure the safe, reliable, and efficient operation of the electrical panel ) /bid number : gem/2026/b/7493216 * /dated: 08-05-2026 & & / bid document 1 / 19
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smoke detection system , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump
Tender For repairing/checking, calibration and testing of different types of relay (protection system) installed in 33kv,11kv controlpanel at main substation of jhingurda mine