Web Analytics Made Easy - StatCounter

Fire Extinguisher Cover Tenders

Get complete information related to latest Fire Extinguisher Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Extinguisher Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Extinguisher Cover Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45358214 Due date: 13 Jul, 202613 Jul, 2026 18.60 Lacs
Tender For corrigendum : tn-18368 supply of various electrical items at kstps, kota - supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota., supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota., supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area., supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifier-iii for u# 6 & 7 of kstps, kota., supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota. kst, supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-ll, kstps, kota., supply of various electrical items at kstps, kota., supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installed at kstps, kota., supply of valves at kstps, kota., supply of misc. rubber items at kstps, kota., repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota, online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota, day to day joinery works inside & outside plant site, kstps, kota, capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps, kota., annual rate contract for 6.6kv vpi and non vpi ht motor rewinding from 175 kw to 4000 kw with new coils of insulation class 'f' and other additional works of stator and rotor.

CTN :45357098 Due date: 13 Jul, 202613 Jul, 2026 18.60 Lacs
Tender For corrigendum : supply of various electrical items at kstps, kota- supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota. , supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota. , supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area. , supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifer-iii for u# 6 & 7 of kstps, kota , supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota , supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-li, kstps, kota , supply of various electrical items at kstps, kota , supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installied at kstps, kota , supply of valves at kstps, kota. , supply of misc. rubber items at kstps, kota. , repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota , online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota , day to day joinery works inside & outside plant site, kstps, kota , capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps,kota , annual rate contract for 6.6kvvpi and non vpiht motor rewinding from 175kw to 4000 kw with new coils of insulation class fand other additional works of stator and rotor

State Government

CTN :45353428 Due date: 04 Jun, 202604 Jun, 2026 7.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al

State Government

CTN :45353431 Due date: 04 Jun, 202604 Jun, 2026 10.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng

State Government

CTN :45353459 Due date: 04 Jun, 202604 Jun, 2026 10.87 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at opd/ipd building bissamcuttack rayagada vide addition/alterations letter no- 8078 dated 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction o

corporations/Associations/Others

CTN :45328583 Due date: 02 Jun, 202602 Jun, 2026 1.23 Crore
Tender For providing annual maintenance contract (amc) and one time repair for various electromechanical equipment installed at patsan bhawan, kolkata, west bengal. - fire fighting system , fire hydrant system , fire extinguishers , fire detection & alarm system, public address system , water treatment plant , sewage treatment plant , hvac system , hvac pumps , electrical panels , 750kva dry type transformer , 750kva dry type transformer , main lt panel (cum dg changeover panel ) , 400kvar capacitor panel , hvac panel , ventilation panel , lift panel, , fire panel , stp panel , wtp panel , isolator panel, , floor db panel, , plumbing panel , sump pump panel , lift lobby pressurization panel , submersible pump panel , 11kv vcb (ht panel) , dbs , toilet inline fan , ventilation fan , exhaust fan , fda,pa,talkback,fire hydrant,extinguisher and sprinkler , stp & wtp plant and sump pump , cctv, intercom, access control , primary chilled water pump , secondary chilled water pump , condenser water pump , secondary controler , cooling tower , ahu with conrol panel , tfa with conrol panel
 Loading, Please wait...

Connect us via What's Up