Get complete information related to latest Fire Alarm Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Alarm Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Alarm Panel Tenders.
Tender For providing of custom bid for services - repair and maintenance of loop network card for firealarm system at swac & armoury at vsn chiloda gandhinagar
Tender For construction of 400 bedded boys hostel building at jipmer campus, puducherry. (civil work): building portion including internal water supply lines, sanitary installation, drainage, demolition of existing quarters and other development works. (electrical and mechanical installation): package c1: providing internal ei, c2: providing firealarm system, c3: providing firefighting system, c4: providing cctv, c5: providing 3 nos. 13 passenger lift, c6: providing 5000 lpd solar water heater, c7: providing network, (agreement no.32/ee(puducherry)/cpwd/2023-24) sub head: risk and cost under clause 14 for providing 2nos. 13 passenger lift.subwork/packages:electrical
Tender For supply, installation, testing and commissioning of micro processor based intelligent addressable main firealarmpanel as replacement of existing old one and allied works at metriabruz super speciality hospital, district - south 24 pgs,2nd call.
Tender For supply of goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. four zone conventional firealarmpanel with gsm. bateries excluded with power wiring, part no. ns-train18-cp-firepanelpcb, operating voltage: 24vdc, 3a power consumption: suitably <3w no of zones: 04 lcd display/rs485/keypad program gps/gprs. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of plywood 06 mm , exhaust fan , whiteboard , tv mount stand 55 inch , power outlet , fireball , fire extinguisher 5 kg , firealarmpanel , floor carpet 10 ft x 15 ft
Tender For tender for supply of signal module , manual call point siga 270 edwards , electronic hooter , power supply card , firealarming loop card , firealarm module-3-cpu3 , isolator module , communication card , fire network communication card , control relay module , monitor module interface unit
Tender For corrigendum : repair/maint of fire detection, firealarmpanel, sprinklers, smoke detectors, fire hydrants and firefighting system at chnc under ge (utilities) udhampur
Tender For balance work of replacement of old defective card in the existing notifier make firealarmpanel and rectify the all firealarm system in old building, mch block,ucms college,jrd hostel
Tender For supply of goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. four zone conve ntional firealarmpanel with gsm. batteries excluded with power wiring, part no. ns-train18-cp-firepanelpcb, operating voltage: 24vdc, 3a power consumption: suitably <3w no of zones: 04 lcd disp lay/rs485/keypad program gps/gprs. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of sitc and maintenance of addressable firealarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop firealarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. firealarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the firepanel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of firepanel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the firealarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi