Tender For supply and installation of fire and smoke detector system and other associated works at 400kv s/s sultanpur under electy. 400kv s/s division, sultanpur
Tender For supply of fire hydrant system d d - ms pipe 100 mm , ms pipe 25 mm , first aid hose reel , hydrant valve , hose box double door and single door , hose pipe 15 mtr and 30 mtr , branch pipe , pump hp 12 tyre mb lpm 900 , starter panel , cable , n r b , butterfuly valve , ball valve , sprinkler , ms union , ms elbow , ms flange , fire alarm panel , smoke detector , mcp manual call point , fire extinguisher abc 4kg , smoke fitting , map online noc from fire department , water tank 5000 ltr , labour charges of all work
Tender For corrigendum : tender for amc of rim seal fire protection system at bpcl bijwasan installation - amc of rim seal fire protection system for 4 efr tanks -8 module- 1st year , amc of rim seal fire protection system for 4 efr tanks -8 module- 2nd year , amc of rim seal fire protection system for 4 efr tanks -8 module- 3rd year , emergency visit charges-1st year , emergency visit charges- 2nd year , emergency visit charges-3rd year , adw 535-1 detector , pressure gauge , sov mm 20101-1.8-2r-b5-s2g , lhd tube ss316 , adw dongle 535- 1 , pneumatic actuator , pressure regulator 17.5 kg , safety valve , rubber ballow , isolated barrier switch
Tender For (1) repair maintenance of central heating plant, lift and fire alarm system installed at hq artrac shimla (h.p.). (2) moei, repair maintenance of pump set, fire alarm installed at cpnr building (ag office, railway board building, sib dormer building) shimla. (3) moei, replacement of lamps and tubes, fire alarm, epabx and repair maintenance of pump set and diesel generator set at grand hotel shimla. (4) moei, repair maintenance of diesel generator set, sub station and central heating plant at himlok parisar, longwood shimla.subwork/packages:sh:- provision of fire alarm and heat detector testing kit.
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For reparing maintenance and upgradation of existing fire fighting hydrent system smoke detector work of head office and subhash yadav bhawan t.t. nagar bhopal
Tender For supply of linear heat detector (lhd) cable (ul or en approved, 105-110 deg c) compatible f or automatic fire smoke detection and suppression system fitted in lhb pantry and power cars as per rds o specification no. rdso/2013/cg-06. operation voltage 24 volts make- alankar cable/fire knock/fire shiel d or any other ul or en approved lhd cable. [ warranty period: 30 months after the date of delivery ]
Tender For supply of smoke detector as per j k exim part no: jk-fdss-1230 for automatic firefire/smoke detection &fire suppression system of lhb coach [ warra nty period: 30 months after the date of delivery ]
Tender For supply of smoke detector as per sanrok part no 2ed-245-3543 for automatic smoke detection and fire suppression system [ warranty period: 30 months after the date of delivery ]
Tender For supply of relay and communication card of vesda compact laser detector of m/s sanrok part no. 2e d-255-4974 or compatible with sanrok make automatic smoke/firedetection with alarm system for ac coa ches as per rdso specification no. rdso/2008/cg-04. (rev-5) , multi functional control card vic-020 for xt ralis vesda vlf-500 detector [ warranty period: 30 months after the date of delivery ]