Tender For auction sale of others - scrap, cond, unserviceable pick up van (mahindra) vehicle in dilapidated condition. quantity=1 number, vehicle number ap29 v 0749 , approximately weight of vehicle=1.735 mt, total nominal weight of lot =1.735 mt location: diesel loco shed premises, moula ali secunderabad. custodian: sse dsl mly, note: chassis & engine number and number plates of vehicle should be remove and handed over to the custodian before effecting delivery. delivery by actual weighment basis only. ds-8 no.073611-25-09123 dated 20.01.2026 and state: telangana. plno.98050011 hsn code 72044100, refer to depot conditions for gstin of state railways, list of holidays and other conditions and special conditions [1] in order to make assessment the purchaser may visit the lot location and inspect the lot and satisfy themselves before bidding [2]post auction no representation shall be entertained.[3] picking & choosing of material is not allowed while taking delivery.[4] cutting is permitted and chassis & engine number of vehicle should be cut and returned to the custodian before effecting delivery. [5] purchaser has to make his own arrangements such as tools, lifting tackles, lifting equipment's such as crane, cutting equipment's and necessary trained men for cutting & loading [6] the purchaser is responsible for providing adequate safety firefightingequipment's on the location at the time of cutting and delivery. [7]. the purchaser shall be liable to make good any damage loss caused to railway property during cutting and delivery.
Tender For corrigendum : supply of life saving and firefightingequipment for bangladesh dredger yard 2121 - life buoys with vessel name and home port , life buoys_vessel and home prt,lght and smk sgnl , life buoys_vessel name and home port_light , life line _l_equal to_30m, dia8mm, orange colour_ , life jackets with retro reflective matl , immersion suits_number as solas_stored , emergency breathing app.,sabre elsa-b-15 , work vests , safety harness , boat hook , stretcher , first aid kit,contain mca,english stickr , rocket parachute flares_set of 12pieces_ , emergency flashlight , line-throwing devices each _ 250m line , distress signals consist_following items , safety plan storage tube,a0size,red , fire blanket,180x120cm,fiberglass , wheeled foam extinguisher _45l_ , spare charges for foam extinguisher_45l_ , co2 extinguisher _5kg_, b, mc5 , spare charges_co2 extinguisher _5kg_,mc5 , powder extinguisher_6kg__stowage arrgt. , spare charges_powder extinguisher _6kg_ , stowage bracket_wheeled foam extinguishr , stowage bracket_co2 extinguisher _5kg_ , stowage bracket_powder extinguisher_6kg_ , portable foam applicator unit , fire locker for fireman outfit , protective suit medium,dark blue_reflctr , protective boots for fireman , protective gloves for fireman , protective helmet with visor for fireman , firemans torch,bright star 2217 ledat , firemans axe _ss with insulated handl , self-contained breathing apparatus , safety harness,protecta first ab17711uni , firemans belt with line,1.5m line , spare oxygen cylinder 6 ltr, 300 bar , valid type approval certificate , certificate_conformity and guarantee certi. , class inspection certificates , warranty extension charge for 1st year , warranty extension charge for 2nd year
Tender For bid to ras bid to ras supply of supply-firefightingequipment as per technical specification tb-434-552-01,clause-8-a,annexure-boq sl no 1 to 70 for pgcil barmer-i new , spares-firefightingequipment as per technical specification tb-434-552-01,clause-8-a,annexure-boq sl no 71 and 72 for pgcil barmer-i new , etc- firefightingequipment as per technical specification tb-434-552- 01,clause-8-a,annexure-boq sl no 1 to 70 and 73 to 78 for pgcil barmer-i new , supply-firefightingequipment as per technical specification tb-434-552- 01,clause-8-b,annexure-boq sl no 1 to 35 for pgcil sirohi extn , etc-firefightingequipment as per technical specification tb-434-552-01,clause-8- b,annexure-boq sl no 1 to 41 for pgcil sirohi extn , supply-firefightingequipment as per technical specification tb-434-552-01,clause-8-c,annexure-boq sl no 1 to 7 for pgcil fatehgarh-iii extn , etc-firefightingequipment as per technical specification tb-434-552-01,clause-8-c,annexure-boq sl no 1 to 8 for pgcil fatehgarh-iii extn
Tender For supply and installation of aerosol based firefightingequipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al
Tender For supply and installation of aerosol based firefightingequipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng
Tender For supply and installation of aerosol based firefightingequipment at opd/ipd building bissamcuttack rayagada vide addition/alterations letter no- 8078 dated 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction o
Tender For supply of establishment of watermanship training centre including electrrical engineer equipment - 1.1. modular construction, easy/ fast installation/ anti-skid surface/ uv protected/ more stable/ excellent buoyancy. 1.2. dimensions-8ft x 6.5ft x 1.5ft (length x width x height). 1.3. buoyancy-1000 kg. 1.4. railings- ms railings epoxy coated with nut and bolts. 2.1 hand held fire extinguisher (2 nos). 2.2. obm 90 hp suzuki outboard motor with accessories (fuel tank, steering remote system propeller, toolkit) & manufacture recommended list of spares (mrls). 3.1. dimensions-4.7m x 2.1m x 0.50m (length x width x buoyancy dia), 05 x chambers and 08 x person capacity. 3.2. hull construction fiberglass, u.v. resistance gelcoat, epoxy resin with vacuum infusion system and sandwich core material. 3.3. engine-90hp 4 stroke remote control engine with steering system. 3.4. accessories - pair of oars, foot pump (electric & manual), repair kit. 4.1. open covered mechanical storage shed (30 ft x 40 ft x 15ft). 4.2. profile sheet 40x30, iron pipe 3x3 inch, parlin 2x2 inch, brick wall 100ftx36inch and 08 x tube light. 5.1. rcc ramp 4m wide x 12m long, rcc pilar 12x12 inch, steell rat 18mm and 12mm. 5.2. reinforced concrete (m25) with non-slip finish. 5.3. ramp rcc thickness 6 inch
Tender For bid to ras supply of refilling and associated works for fire extinguishers installed at nhpc d d - refilling of fire extinguishers as per sl. no a.1 of boq of tender document , refilling of fire extinguishers as per sl. no a.2 of boq of tender document , refilling of fire extinguishers as per sl. no a.3 of boq of tender document , refilling of fire extinguishers as per sl. no a.4 of boq of tender document , refilling of fire extinguishers as per sl. no a.5 of boq of tender document , refilling of fire extinguishers as per sl. no a.6 of boq of tender document , refilling of fire extinguishers as per sl. no a.7 of boq of tender document , refilling of fire extinguishers as per sl. no a.8 of boq of tender document , refilling of fire extinguishers as per sl. no a.9 of boq of tender document , refilling of fire extinguishers as per sl. no a.10 of boq of tender document , refilling of fire extinguishers as per sl. no a.11 of boq of tender document , refilling of fire extinguishers as per sl. no a.12 of boq of tender document , refilling of fire extinguishers as per sl. no a.13 of boq of tender document , refilling of fire extinguishers as per sl. no a.14 of boq of tender document , co2 type fire extinguishers sl. no b.15 of boq , co2 type fire extinguishers sl. no b.16 of boq , co2 type fire extinguisher sl. no b.17 of boq , co2 type fire extinguisher sl. no b.18 of boq , co2 fire extinguisher sl. no b.19 of boq , co2 fire extinguishers sl. no b.20 of boq , co2 fire extinguisher sl. no b.21 of boq , co2 fire extinguisher sl. no b.22 of boq , mechanical foam fire extinguisher sl. no b.23 of boq , painting affixing mandatory stickers sl. no b.24 of boq , painting affixing mandatory sticker sl. no b.25 of boq , painting affixing mandatory sticker sl. no b.26 of boq , painting affixing mandatory sticker sl. no b.27 of boq , spare testing of fire extinguisher cylinder sl. no b.28 of boq , spare hydraulic testing of fire extinguisher cylinder sl. no b.29 of boq , spares hydraulic testing of fire extinguisher cylinders sl. no b.30 of boq , spares hydraulic testing of fire extinguisher cylinder sl. no b.31 of boq , spares hydraulic testing of fire extinguisher cylinder sl. no b.32 of boq , spare hydraulic testing of fire extinguisher cylinder sl. no b.33 of boq //bid details 2 / 28