Get complete information related to latest Fire Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Item Tenders.
Tender For tender for supply of fire hydrant system at uco zo bbs - monoblock pump , with motor 5.5 kw , accessories , base plate , capacity 900 lpm , discharge head 40 to 45m , control panel with local push button , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning of class c ms pipes 100mm nominal dia , supplying , installing , testing and commissioning of class c ms pipes 80mm nominal dia , supply , installation , testing & commissioning of ci butterfly valves , supply , installation , testing & commissioning of ci gate valve , supplying , installing , testing and commissioning of c.i. non-return valves , supply , installation , testing & commissioning of fire brigade inlet connection of 3 way , m.s. hose cabinet stand mounted type fabricated out of m.s. sheet , single headed hydrant valve , 2 lengths of 15 m long , 63mm dia rrl hose , 1no. stainless steel short branch pipe of 63 mm dia. with nozzle. , hose reel drum of swinging type with 19mm dia rubber braided hose of 36 m , fire exit signage at each entry of staircase on every floor , floor identification signage at each stair enclosure on every floor , camc for 4 years after expiry of one year warranty of fire fighting system
Tender For tender for supply of supplying , installing , testing and commissioning approved make microprocessor based single (01) loop , networkable addressable fire alarm control panel , supplying , installing , testing and commissioning approved make digital audio amplifier. , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning approved make modbus interface gateway , the mimic annunciator for the fire alarm control panels (facp). , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector , supplying , installing , testing and commissioning approved make addressable manual call point , supplying , installing , testing and commissioning approved make addressable control module for sounders , supplying , installing , testing and commissioning approved make addressable relay module for ahu , access control , lifts , staircase pressurization , fire suppression & other third party outputs , supplying , installing , testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement , supplying , installing , testing and commissioning approved make response indicator , supplying , installing , testing and commissioning of hooter cum strobe with in-built lithiumion battery , supplying , installing , testing and commissioning approved make 2w multi-tap wall mount speakers , supplying , installing , testing and commissioning of approved make auto dialer which supports gsm and pstn both , supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable , red in colour. , camc for 4 years after expiry of one year warranty of addressable fire detection system
Tender For addition of stand by hvac secondary pumps with variable frequency drive based control panel in the existing centralized ac plant with associated modification in chilled water line header at administrative building complex supreme court of india new delhisubwork/packages:improvement of electrical supply to pumps of hvac, fire fighting etc at administrative building complex
Tender For bid to ras supply of ductable ac 8.5 tr , refrigerant piping as above for 8.5 tr machine , drain piping 25 mm dia , supply and fabrication of ms structure to support the machine, outdoor and ducting , control cable , power cable 4c x 6 sqmm , power cable 4c x 50 sqmm , ms cable tray 50 x 100 x 50 x 1.6 mm , 22g oval ducting , supply of fire-retardant flexible canvass connections , supply of anodized extruded aluminium supply air double louver grills with volume control damper , supply of electrical panel with 1 no suitable capacity incomer and 6 nos suitable rating outgoing feeder for ductable units , providing of outdoor stands duly painted , providing of ss 304 drain tray under the ductable units , supply of portable air conditioner capacity 1 tr , installation testing and commissioning charges , freight charges including packing forwarding, transportation, insurance and unloading of material
Tender For supply, erection, testing & commissioning of training simulator for fire fitting control panel with detection system at metro railway training academy, kolkata, as per specification with 2 years warranty[ warranty period: 24 months after the date of delivery ]
Tender For bid to ras corrigendum : supply of deliverables as per table-5 for fire alarm and control panel system as per edt-2875or etb , supply of deliverables as per table-6 for fire extinguishing system as per edt-2875 for etb at afs k , installation, testing and commissioning of fire alarm and control panel system for etb as per clause , installation, testing and commissioning of co2 based fire extinguishing system for test cell, fuel r
Tender For corrigendum : supply of fire detection and alarm system powergrid silchar sub station : : - smoke detection system , fire detection and alarm system for control room , fire detection and alarm system for switchyard panel room of 9 m length , fire detection and alarm system for 400kv gis hall , fire protection system for local relay room for gis , indoor fire detection and alarm system for fire fighting pump
Tender For providing of repair and overhauling service - uninterruptible power supply (ups); l 1639 aft fire and sprinkler motor not working 415 v 3 ph 30 kw suspect defect on control panel; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1641 battery charger 24v 25a of emergency da starting batteries is not working; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1595 port qrib system not working; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1637 forward engine room ventilation system motor es 1 22kw not working in all modes; yes; buyer premises,repair and overhauling service - uninterruptible power supply (ups); l 1628 02 in nos ships galley hotplates not working in high medium range of operation; yes; buyer premises
Tender For corrigendum : supply of fd heating sys 2629 d d - 1100 volts grade multi standard copper conductor of size 1.5 sqmm single core frls confirming to is 1554 , cable pvc insulated electric cables heavy duty 1100 volts grade multi stranded copper conductor of size 4 sqmm single core frls confirming to is 1554 part 1 1988 , pvc casing capping of size 3 oblique 4 medium grade snow white make anchor ssk cona , switch piano 5 amp 230 volts flush type one way snow white make anchor ssk cona isi equivalent , led tube light fittings 15w 230v box type 4 feets with crca body pre coated white and prewired for led tuble complete make havells bajaj philips cromption isi equivalent , screw full thread 6 x 19 mm isi marked 200 nos pkt , pvc switch board snow white size 7 inch x 4 inch for sockets and switches db make supreme polycab finolex isi equivalent , pvc switch board snow white size 8 inch x 10 inch for main switches db make supreme polycab finolex isi equivalent , pvc l bend and t junction joint for pvc casing and capping confirming to is 3419 part 3 make supreme polycab finolex isi equivalent , switch socket combination snow white multipurpose 2 in 1 15 amp 230 volts make anchor ssk cona isi equivalent , service bracket 40mm dia gi tubing medium grade 1.5 mtr long make jindal tata kalinga isi equivalent , cement 43 grade opc packed in hdpe bag each 50 kg wt conforming to is 8112 1989 birla gold ambuja ultratech isi equivalent , coarse sand free from vegatative materials , coarse aggregate 20mm graded , coarse aggregate 40mm graded , hardcore 63 to 90mm , mild steel framed work such as truss rafter purlins and ms plate make tata sail jsw isi equivalent , mild steel bars of size 6 to 8mm dia conforming to is 432 part i 1982 make tata sail jsw isi equivalent , mild steel bars of size 10mm and above dia conforming to is 432 part i 1982 make tata sail jsw isi equivalent , the pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50 mm thick an colour having a tensile strength 550mpa of size 10 feet x 3 feet , the pre painted galvalume aluminium zinc coating gi based plain steel 0.50 mm thick an colour having a tensile strength 550mpa. , mild steel self drilling screw with washer size 3 inch isi marked 100 nos per pkt , anti corrosive red oxide zinc chromate primer confirming to is 5 2004 make berger asian nerolac isi equivalent , synthetic paint enamelled black confirming to is 5 2004 make berger asian nerolac isi equivalent , painting brush 3 inch isi marked , ms nut and bolt of length 100 mm fully thread , ms nut and bolt of length 0.45 m 12 mm dia nuts and washers for fdn bolt , iron welding rod confirming to is 814 2002 isi marked 3.15mm thick 100 nos per pkt , ms binding wire panel radiator: supply of wall mounted steel panel radiators of heat output of 3200 kcal/hr,colour), baked in high gloss finish with and including all necessary fittings as per ne 442 standards , m.s made radiator has both core and tank made of mild steel. the radiator supplied should transfer heat from the fluid inside to the aire outside. the radiator will have thermostat control sensor to control the room temparature, make: eurotherm/maktek/bharat works/isi equivalent., boiler: supply of vertical fire tube boilers (heat output of 50000 kcal/hr) (58.02 kw/hr) with stainless steel dampers. the boiler will run on hsd/kerosene and will be rated as per the heat load calculation. the presure rating should be upto 160 pai. now emissions should not exceed 30 ppm. the working temperature should be upto 195 degree pehrenheit. the efficiency of boiler should be not be less than 90% make: bharat works inc of model no: ch-70l of 50000 kcal/hr heat //bid details 2 / 35