Get complete information related to latest Fire Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Panel Tenders.
Tender For est. no. ow/c/cd/4805 4806 /2026-27 (a) providing cabling work with switchgear and allied services from existing diesel generator set to firepanel backside of pns building in st. george hospital , fort, mumbai. (b) providing cabling work with switchgear andalli
Tender For auction sale of 262976_bhubaneswar_capacitor bank panel_630 kva,262976_bhubaneswar_scrap firepanel_400amp,262976_bhubaneswar_scrap pahu_57.2kw (16tr),262976_bhubaneswar_fire extinguisher 25kg-1,6kg-38,4.5kg-30_25kg
Tender For supply of goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. four zone conve ntional fire alarm panel with gsm. batteries excluded with power wiring, part no. ns-train18-cp-firepanelpcb, operating voltage: 24vdc, 3a power consumption: suitably <3w no of zones: 04 lcd disp lay/rs485/keypad program gps/gprs. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the firepanel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of firepanel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For supply of 2 zone firepanel of afds with battery backup , abs manual call point break or resettable type re 737m , smoke detector with base , abs sounder 24v 95 105db re 24s flasher , 2c x 1.5sqmm frls armoured cable with laying charges , amfe 5kg , device installation charges
Tender For supply of fire alarm and detection system e e - 2 loop addressable firepanel , addressable photo electric smoke sensor with base , addressable manual call point , addressable hooter cum strobe , input module , addressable heat detector
Tender For auction sale of depot miscellaneousellaneous scrap - cond. electrical item with or without non-ferrous attachment consisting of panel box, rbc box, rectifier , governes,double inlet blower , small motor, transformer. compressor, inverter blower with motor and small motor , wiper motor , single coupler, mcbg , fuse box, control unit eps and other various electrical items, card main switch and various type of miscellaneous and similar item dioeds d.c.converter , track cap indication panel, control panel, electrical firepanel , air flow relay, bander relay small blower motor, bush mani fuse mcb panel , fuse link , selector switch, censervator tank coil. with or without non-ferrous and other attachment . note:- loading after 15.00 hrs will not be allowed