Web Analytics Made Easy - StatCounter

Fire Protection Detector Tenders

Get complete information related to latest Fire Protection Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Protection Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Protection Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :44802894 Due date: 29 Apr, 202629 Apr, 2026 NA
Tender For supply of n1350 000215 deep search underwater metal detector , n1325 001306 installation kit bomb bomb suppression blanket , n1385 000028 tool kit fuze remover remote mechanical impact wrench , n1385 000029 fuse removal adaptor , n1377 000325 firing device explosive actuator improvised disruptor tool , n1385 000026 car remote opening tool , n1385 000027 tool kit fuze remover remote rocket wrench , n1385 000031 chemical detection kit , n1385 000032 tool kit explosive ordnance disposal non magnetic tool kit , n8405 004730 jacket 1 utility tool jacket for eod technician , n8465 002907 ballistic protection eyewear safety goggles , n8465 002905 field pack eod back pack , n8465 002904 snap link rappeller carabineer , n8470 000076 bomb disposal suit , n8470 000077 helmet explosive ordnance disposal bp helmets , n8415 002626 helmet safety , n6665 000627 detector explosive ordnance fibre optic survellance set , nsn6665 722251652 explosive detector explosive vapour detector ) /bid number : gem/2026/b/7348012 * /dated: 08-04-2026 & & / bid document 1 / 20

State Government

CTN :43927260 Due date: 08 Apr, 202608 Apr, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref
 Loading, Please wait...

Connect us via What's Up