Get complete information related to latest Fire Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Work Tenders.
Tender For supply of 415 v,200 a ac and vent pdb_srr-ub as per nit , 415 v, 400 a ac and vent pdb_ss-112 as per nit , 415 v, 100 a ac sub-pdb_srr-ub as per nit , 415 v, 160 a ac sub- pdb_ss-112 as per nit , 415 v, 63 a vent wall mounted db_srr-ub as per nit , 415 v, 100 a vent wall mounted db_ss-112 as per nit , 415 v, 63 a ac-vent wall mounted db_swas room as per nit , 230 v, 32 a wall mounted db_cctv as per nit , 415 v, 200 a sh pdb as per nit , 110 v, 400 a dcdb-1 as per nit , 110 v, 125 a dcdb-2 as per nit , local dol starters as per nit , commissioning spares as per nit , tools and tackles as per nit , mandatory spares as per nit , 16a_lumpsum price for travel by lt switchboards oem to and from site per visit_ 1set is equals to 1 visit_as per nit , 16b_lumpsum price including lodging, boarding etc for services at site for supervision of e,t and c of swbrds by swbrds oem_1 set is equals to 6 man-days_ as per nit , 17a_lumpsum price for travel by lt swbrd oem _ 1set is equals to 1 visit_as per nit , 17b_lumpsum price for serv at site for mod or addl job on swbrds_ 1 set is equals to 6 mandays_ as per nit , training on lt swgr at vendor or oems works as per nit_1 set is equals to 5 days
Tender For corrigendum : supply of quench cum venturi cum packed bed column cum bop as per annexure_3_ price bid format cl.1.1a_1.1b_1.1c , gas to gas heat exchanger as per annexure_3_ price bid format cl.1.1 d , sintered metallic filter system as per annexure_3_ price bid format cl.1.1 e , mercury guard bed with catalyst as per annexure_3_ price bid format cl.1.1 f , special tools _tackles as per annexure_3_ price bid format cl.1.2 , consumables, lubricants, commissioning spares as per annexure_3_ price bid format cl.1.3 , spares, special maintenance tools as per annexure_3_ price bid format cl.1.4 , mandatory spares as per annexure_3_ price bid format cl.1.5 , supervision services _per diem rates per service engineer _as per annexure_3_ price bid format cl.2.1 , supervision services _travel expenses from vendor works to project site and back _as per annexure_3_ price bid format cl.2.2
Tender For corrigendum : supply of lt-radar non contact type - top mounted ,10m, 4inch 300 rf, 2wire hart, al , lt-radar non contact type - top mounted , 20m, 4inch 300 rf, 2wire hart, al , lt-radar guided wave type without chamber , cc 5m, 2inch 300 rf, hart, al , lt-radar guided wave type without chamber , cc 5m, 4inch 300 rf, hart, al , lt-radar guided wave type with cs chamber , cc 1500mm, 300 rf, hart, al , mandatory spare for lt radar -non cantact type - bom 5 percent or minimum 01 no. -whichever is higher- of each type of electronic card , mandatory spare for lt radar guided wave type - bom 5percent or minimum 01 no. - whichever is higher- of each type of electronic card , supervision of erection and commissioning services charges at site including lodging, boarding, local travel, insurance, etc.unit rate is equal to per man day charges , supervision of erection and commissioning visit charges - travel expenses .unit rate is equal to per visit travel expenses , lt-radar guided wave type without chamber , cc 5m, 2 inch300 rf, hart, al , lt-radar guided wave type with cs chamber , cc 900mm, 300 rf, hart, al , lt- radar guided wave type with cs chamber , cc 1200mm, 300 rf, hart, al , lt-radar guided wave type with cs chamber , cc 3650mm, 300 rf, hart, al
Tender For corrigendum : carrying out fireproofing works on structures and equipments as per eil standard specification in connection with the composite work for avu units part a for panipat refinery expansion project of iocl at panipat haryana
Tender For corrigendum : supply of steam water analysis system main spares and e and c c c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , conductivity analyzer -online retractable type , sample handling system for main steam superheated , sample handling system for main steam saturated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for condensate cep outlet inlet cooling wtr , sample handling system for dm water , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 6 mandays at manufacture works and 6 mandays at site , mandatory spares as per tech specs , supervision of e and c services charges at site , supervision of e and c visit charges
Tender For corrigendum : supply of mass flow meter - line size 3 inch flange rating 300 rf, pfo , mass flow meter - line size 4inch, flange rating 300 rf, pfo , mass flow meter - line size 6inch, flange rating 300 rf, ng , mass flow meter - line size 18inch, flange rating 300 rf, rfg , mass flow meter - mandatory spares , supervision of erection and commissioning services charges at site including lodging, boarding, local travel, insurance, etc.unit rate is equal to per man day charges , supervision of erection and commissioning visit charges -travel expenses .unit rate is equal to per visit travel expenses , magnetic flow meter - main supply - line size 10 inch , flange rating 300rf, transmitter housing cast aluminum , magnetic flow meter -mandatory spares , vortex flow meter - main supply -meter size , material 2 inch 300 rf and ss316 transmitter housing cast aluminum , vortex flow meter - mandatory spares
Tender For eoi- cum-financial bid for undertaking consultancy services for preparation of dpr, tender documents, bid process management, supervision quality control and measurement of work at site for development of tribal research institute (tri) campus.
Tender For eoi-cum-financial bid for undertaking consultancy services for preparation of dpr, tender documents, bid process management, supervision quality control measurement of work at site for construction of automated driving test tracks (adtt)
Tender For firework at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f