Get complete information related to latest Fishery Harbour Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fishery Harbour Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fishery Harbour Tenders.
Tender For supply of x3-mg19-dynaf-2-36-002-07 reducing ring for drain cock , x3-mg19-dynaf-2-19-010-07 hose clamp , x2-misc-mg-701-002-00 wood block 25x18x450 , x3-mg19-dynaf-068103-157d oil spray jet set 1 set of 4 pcs , x3-mg19-dynafn-011-118-16 hexagon nut , x2-mg19-dynaf-3-13-015-07 end plate , x3-ixc-kr-4h-1613-16-0-00 valve collet , x2misc4063-400-101-90 capacitor 1. 0uf 850 v ac 10 percentage mkp , x2-misc4232-429-001-96 rectifier bridge 25a 1200a , x2-mg19-dynaf-7-00-171-07 cover for control unit gen , x2-misc-457945462765 igbt adaptor card 2105 , x3-ixc-kr-6h-247-30-0-00 piston ring set , x2-mg19dynaf-6-15-039-07 terminal holder , x2-mg19-dynaf-813-931-07 terminal w is equal to 6. 2 , x2-misc-3dtcr4759-421-901-49 control terminal , x3-mg19-dynaf-2400393-530-82 cover
Tender For corrigendum : invitation for expression of interest (eoi) for design, engineering, supply, installation, training and commissioning of trailer mounted hvlr (high volume long range) monitor for fighting full surface fire in 79 meter dia. crude tank at bpcl mumbai refinery, 79 meter dia. crude tank at bpcl kochi refinery, 68 meter diameter tank at bpcl bina refinery at madhya pradesh & crude oil terminal (cot) vadinar at gujrat
Tender For corrigendum : aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
Tender For supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges