Get complete information related to latest Flange Wear Gauge Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flange Wear Gauge Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flange Wear Gauge Tenders.
Tender For supply of 313000200 pressure switch 0 to 10 kg , 313000204 pressure switch 10 to 30 kg , 370600062 vacuum gauge 0.1 to 0 , 313000198 pressure gauge 0 to 10 kg , 313000066 compact capsule type pressure gauge
Tender For corrigendum : supply of male female joints with 3 way vacuum sto , dean stark distillation apparatus 19or22 , dean stark distillation apparatus 24or40 , still head 500 ml , still head 1000 ml , vacuum manifold 5 port , 2 neck flask 14or20 with side port 100m , 2 neck flask 19or22 with side port 100m , 2 neck flask with side port 250ml , 2 neck flask with side port 500ml , solvent transferorstorage flask , additionorstorage funnel with t bore , filter tube 2 side ports porosity 10 2 , dewar flask hemispherical low form 500 , reaction tube with hi vac valve 100 ml , reaction tube with hi vac valve 200 ml , joint clip size 14 , joint clip size 19 , joint clip size 29 , wide mouth dewar flasks 665 ml , 1 ml syringe , dga glass syringe 5 ml , dga glass syringe 10 ml , dga glass syringe 100 ml , dga glass syringe 50 ml , firestone valve , hi vac silicone grease , suba seal white 14 mm , powder dispensing funnel , cannula gauge 15 or 16 l 30 36 in. , cannula gauge 18 length 18 24 in. , cannula gauge 18 length 30 36 in. , cannula gauge 22 length 18 24 in. , cannula gauge 22 length 30 in. , suba seal white 22 mm
Tender For supply, installation and trials of laboratory instruments equipment apparatus with training for quality control ii division at siliguri, p.w.(roads) directorate - nomenclature of machine/instrument and work required: supply, of only vacuum pump cum controller required for existing digital 4 station vacuum indicator for absolute viscosity test. the same will have to he installed on the existing machine and after installation, necessary trials are to be carried out. relevant is code: is: 1206: 2022 (part ii). specification: the pump connected with the vacuum system should be capable of maintaining a vacuum within 2 0.05 cm of the desired level up to and including 30 cm of mercury, and should have the capability of holding the desired pressure throughout the period of a particular test. the pump should have both analogue (with divisions of 0.05 cm of hg) and digital pressure gauge (capability of displaying minimum of 0.05 cm of hg). the vacuum pump controller should be supplied with a 4-position manifold to apply vacuum simultaneously up to four positions and perform viscosity determinations. equipped with dedicated on/off switches for each position and supplied with blue silicon tubing. the pump should have the capability of withholding the pressure set for tests and also maintain it throughout the test. vacuum pump should be the part of vacuum system [pump should be inbuilt with in the vacuum system along with analogue and digital display of vacuum). note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of q.c.-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply, installation of u-tube, modified reverse flow viscometer for opaque liquid required for kinematic test of bitumen. details: tube no. 6 & 7 with 01 no. stand each. relevant is code: is 1206 (part 3): 2021 specification: note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction of engineers of qc-ii division at siliguri. 3. two year comprehensive warranty of total system from the date of satisfactory completion of onsite installation, commissioning and training of the instrument., nomenclature of machine/instrument and work required: supply & installation of serological water bath. specification: the bath should have double walled structure, having facility of digital controller cum indicator. the bath should have stirring arrangement. inside wall should be of stainless-steel seamless ss 304 seamless, min. thickness 1.0 mm, with rounded corners for easy cleaning with proper drainage system having ptfe valve and hose pipe (15mm inner dia. min). outer wall to be of ms and properly insulated with cfc-free high-density insulation. minimum temp. range is 5°c to 95°c, 20.2°c. size should be minimum 28 l: -600 w 400d 350 h mm; for 8 standard racks, with adjustable height, compatible with common test tubes (10-50 mm dia.) and other bottles/beakers. note: 1. calibration certificate will have to be furnished and should be valid for atleast 10 months from the date of supply. 2. necessary tests and trials will have to be carried out to the satisfaction, nomenclature of machine/instrument and work required: supply & installation of burette stand with clamp specification: boss head & rod (with stainless steel corrosion resistant rod (length 18") the rod diameter is 1 cm and solid black coated support stand base (6"x4"). should be made of high-quality anti-corrosion & rust-proof stainless steel. the base should be padded to prevent scratches on the surface and better gri