Get complete information related to latest Flash Drive Diskette Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flash Drive Diskette Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flash Drive Diskette Tenders.
Tender For supply of monitor led lcd , smps 12 pin , key board and mouse combo pack hp , hard disc 500 gb , epson ink pad , brother 2365 drum unit , uhp based projector lamp , hdmi cable
Tender For corrigendum : rfp for selection of an agency for providing on-site comprehensive annual maintenance contract services for ict equipment supplied under the coding and robotics education in schools (cares) scheme in the state of goa on an as is, where is basis - single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)(1st year cost), single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)( 2nd year cost), single board computing device (technical specifications: intel x64 processor 64-bit j4105 upto 1.5 ghz, 4mb cache with intel integrated graphics 600memory: 8gb ddr4 2666 mhz ramstorage: 64gb m.2 ssd,connectivity : realtek dual band (ax card) ac 1200 with bluetooth 5.1 mini pciex card, realtek 1 gbps ethernet porti/o: hdmi (upto 4k @ 100hz), 2 x usb 3.0 ports, 4 x usb 2.0 ports, vga port, combo audio jack,100 keys or higher usb keyboard,keyboard type: standard keyboard,lcd monitor:screen size: 19 inch,video conferencing camera,headphone with mic)( 3rd year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(1st year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(2nd year cost), wifi based router (standard: ieee802.11/a/b/g/n/ac,interface: wan gigabit port, minimum 4 lan gigabit ports.antenna: minimum 4 external omni directional antennas.,data rate: upto 867 mbps (ac 1200),power adapter: ac input: 100-240 v 50hz to dc adapter)(3rd year cost)
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For doitc nagaur e-mitra plus repairing tender fy 26-27 - (system board, cpu unit, hard disk, web camera, led/lcd/monitor, processor, smps, power adapter
Tender For supply of medical equipments in various locations in distt. patiala (as per detail attached) - supply, ot table, hydraulic operated with smooth gear mechanism, double cylinder loak proof, stainless steel, medical refrigerator 250-300 ltr. with shelf temperature setting (approx) +0 to +8 c, voltage 220 - 240 v, freguency 50/60 hz, ot light ceiling mounted single dome 12 led with led 50000 lux 22" dia dome with 4 reflector of 8 dia. auto spring balanced, heavy duty step down transformer. sterilizable central handle., ecg machines 12 leads single print 10-hour standby time, continuous print more than 3-hour, auto-analysis and auto-diagnosis for routine ecg parameters, built-in large capacity memory, casseta 14*x17* for pre-installed dr system for xray at mkh patiala make agfa, semi auto analyzer with built in software for the calculation and curve plotting. light source led, open system capable using all grand reagents and all the test programs should be in open mode. user interface: lcd display with touch key board, flow cell type permanent flow cell. memory >= 500 tests, in-built thermal printer, in-built thermal printer required, accessories to be supplied 1. micro pipettes (* no.) - 2 variable (5-50), (100-1000), small tips 500 nos. & large tips- 500 number, laproscopic surgical instrument set, ups 1kva offline for ultrasound machine simulated sine wave or better voltage avr mode 200-245v voltage battery mode 230vac +10%e frequency (htz) on battery 50/60hz + 0.1hz, 30 min backup, iso 14001/bis certification, biphasic defibrillator monitor 8.4" inch size screen, charging time of less than 9 seconds for maximum energy of 2 to 360 joule, synchronized & asynchronized cardio-version and having in-built thermal printer, monitoring 12 lead ecg, heart rate, spo2, & nibp, 230v, 50hz ac mains and battery capable of delivering up to 50 shocks at 200 joule, iso /en 60601-1, certified, oem warranty 3 year, boyles apparatus, 4 cyl mechanical with 3 gas system with hypoxic guard with 2 vaporizer (halothane & isoflurane), ice lined refrigerator (ilr) 144 lt 220 volt 50 hertz, in build stabilzer led (3-digit digital display), galvanized steel, stem alchol thermometer, ground clearance (min) 100 millimeter, holdover time (in a continuous external temperature of +43 degree celsius -24 hour, sets of instruments used for laparoscopy surgerya. gull bladder extractor, b. call stone spoon extractor c. 10 mm safety trocar, d. aspiration needlee. 5mm and 10 mm reducers, metallic continuous spray pump 1.5 ltr. (ganesh pump) type: hand compressor sprayer, tank: brass. tank capacity: 1.5 lit. pump barrel brass, working pressure, 40 - 45 psi, baby warmer steel tubular structure pretreated and powder coated heater rotation +90, bed tilt should be 615 , led displays, aulomatically cut off at 38 degree celsius, probe accuracy specilication: +0.1 c @ 30 c to 42 c, 200 to 240vac 50 hz supply