Get complete information related to latest Flash Driver Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flash Driver Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flash Driver Tenders.
Tender For supply of ruggedized rack with 10 slots ethernet backplane dual power supply , redundant hsby processor module m580_level 6_ conformal coated for rio with battery , 4gb memory card for m580 cpu , m580 hot standby single mode fiber optics sfp socket adapter with hsby cable , ethernet module m580 3 port ethernet communication conformal coated , redundant hp ac power supply module x80 230v ac , ethernet fiber converter mm lc 2ch 100mb
Tender For tender for supply of spares for rockwell plc installed at grep compressor station gail vaghodia -spares for rockwell plc installed at grep compressor station gail vaghodia -relay contact o p isolated 1794 ow8 8bit , flex i o module frequency input no of i , module analog i p 1794 ie8 12bit 8point , o p module source 16 24v 1794 ob16p , analog output module 16 bit 1794 of4i , analog input module 16 bit 1794 if4i , flex i o term base allen bradley cat n , i p mod non isolated t c 1794 irt8 , plc slot rack p n 1756 a7 , plc chasis 10 slot control logix , ethernet comm module 1756 enbt allen , controllogix dc redundant power supply , power sup mod plc p n 1756 psca2 allen , adapter redundant media 1794 acnr15 , voted eods relay module xm 442 , sink i p module 24vdc 16poit 1794 ib16 , dualspeedmodulexm 220 , plc controller cat no 1756 l71 , fast analog 4 cur volt in 2 cur volt ou , prosoft com mod plc p n mv156 mcmr allen , modbus ethernet module mvi56e mnetcr
Tender For supply of isp gateway router with 10 lakh route , isp routable layer- 3 distribution switch with redundant power supply , isp layer-2 distribution switch
Tender For supply of analytics server as per rdso specification no. rdso/spn/tc/65/2021, rev. 6.0with the latest amendment/revision dell poweredge r750 with 2 x intel xeon(silver 4314 2.4g.16c/32t, 10.4gt/s, 24m cache 0r better) processor, 192gb rdimm, 3200mt/s memory, 4x1.2tb hard drive ise sas 12 gbps 10k 512n 2.5in hot-plug hard drives, perc h755 sas front internal storage controller, dual, hot-plug, power supply redundant (1+1), 1400w, mixed mode power supply, nvidia ampere a30, pcle, 165w, 24gb passive, double wide, full height gpu or better gpu of dell make ]
Tender For tender for supply, installation testing and commissioning of it & electrical components for vams - supply and installation of 12u rack, supply and installation of 12 port managed n/w switch, supply and installation of 8 port managed n/w switch, 4+2 poe switch for power up the ip camera, supply and installation of gigabyte media convertor, supply and installation of patch cards, supply and installation of power jb, supply and installation of control jb, supply and installation of long-range wifi router, supply and installation of 6c sc ofc cable, supply and laying of 3c*2.5 sqmm armoured cable, supply and laying of cat-6 cable, supply and installation of 42 u rack, supply and installation of 24 port managed switch, supply and installation of pdp pannel, supply and installation of p10 display unit with 2 feet, * 6inch for driver information purpose, supply and installation of 10kva ups 3phase in, 1phase out with redundant setup, supply and installation of smf battery 42ah, supply and installation of battery stand and interlinks, flp gland, non flp gland
Tender For corrigendum : supply of 10 kva ups system in (1+ 1) parallel redundant equal load sharing config with power spds and acdb , amc of ups system for 5th year after completion of defect liability period , amc of ups system for 4th year after completion of defect liability period , amc of ups system for 3rd year after completion of defect liability period , installation of ups as per technical specifications and tender terms & conditions , 2v vrla battery in dual string for 4 hrs backup for 10 kva ups as per technical specifications , installation & commissioning of battery banks , amc of ups system for 1st year after completion of defect liability period , amc of ups system for 2nd year after completion of defect liability period , dismantaling of ups as per technical specifications and tender terms & conditions