Get complete information related to latest Flat Rack Container Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flat Rack Container Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flat Rack Container Tenders.
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage
Tender For corrigendum : supply of dc lead acid or ni cd batteries for ntpc lara project - 220v lead acid or ni cd battery suitable for main plant , electrolyte for first filling plus 10percent extra in nonreturnable container , wooden racks , stand insulators , intercell, inter row, inter bank connectors , cell numbering tags with fixing arrangement 1set , anti-splash type vent plug , nickle coated connection hardware plus 5percent extra , cable clamps with fixing hardware , pvc or cfrp spill trays under battery set battery to have spill tray covering every cell , battery trolley for entire project , hydrometer , cell testing digital voltmeter 3-0-3v with testing leads , wall mounting type holder for hydrometer and thermometer , set of hydrometer syringes suitable for vent holes in different cells , thermometer for measuring electrolyte temperature , specific gravity correction chart for lead acid battery only , rubber apron , pair of rubber hand gloves , set of spanners , no smoking notice , goggles industrial , instruction card , minimum and maximum temperature indicator for each battery room , acid or alkali mixing jar , battery health monitoring system for each battey cell of battery sets as per sl.no. a.1.1 above , 220v lead acid or ni cd battery suitable for offsite area , electrolyte for first filling plus 10percent extra , ms racks properly treated with alkali resistance powder , stand insulators plus 5percent extra , intercell inter row inter bank connectors , e and c spares for battery 1 and 2 gloves , e and c spares for battery 1 and 2 vent plugs , e and c spares for battery 1 and 2 intercell connectors , supervision of erection -battery -mandays , supervision of erection -battery -visit , supervision of commissioning -battery -mandays , supervision of commissioning -battery -visit , supervision of commissioning -bhms -mandays , supervision of commissioning -bhms -visit , mandatory spares for battery 1 complete dry cell , mandatory spares for battery 1 inter-cell connectors with hardware , mandatory spares for battery 1 bhms spares , mandatory spares for battery 2 complete dry cell , mandatory spares for battery 2 inter-cell connectors with hardware