Get complete information related to latest Flex Coupling Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flex Coupling Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flex Coupling Tenders.
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For corrigendum : spacer coupling for pa fan as per drg no. 3-55-830- 02267 to transmit 3200 kw@1490 rpm. , forged steel pin bush type flexcoupling as per drg no. 3-56-870- 05424 to transmit 110 kw@ 1480 rpm.
Tender For corrigendum : supply of fp9750266218 connecting coupling , fp9750628047 connecting coupling , fp9750628110 flexible coupling var no 11 , fp9750628535 element blade assembly with fasteners , fp9750628128 flexible coupling var no 12 , fp9750693060 connecting coupling cvp
Tender For corrigendum : supply of , frl 1 or 4 inch with pressure guage , quick exhaust valve 1 or 4 festo or norgen , quick exhaust valve 1 or 8 festo or norgen , spray,wd-40 cap- 400ml btl , cassette ss as per kosan carousel , guide rod for kosan introduction unit , 5 or 2 spring return valve , 1 or 2inch -f, ss ball valve , magnetic sensor , tepar strip for 90 deg bend , lock pin,chain conveyor duplex chain , switch,139a714,carousel kosncris - pressure switch , ejection puller arm , ejection pusher arm , needle valve , pneumatic cylinder 12mm or 16mm with fittings , shaft size- 40mm x 280 mm en-8 , shaft size- 40mm x 4000 mm en-8 , nut bolt 1.5inch x 10mm , nut bolt 1inch x10mm , f-mounting , ejection flexible coupling , pneumatic cylinder- 50 or 160- norgen or smc , toggle joint rod- lt-200 mm , pin of non-pneumatic filling gun , bearing no.6206 , bearing no.6304 , gas stop valve lpg 1 or 2inch , steel plate thick 10mm size 0.5mx0.5m , key pad for cuc card steel mk1v , key pad for cuc card mkii , anchor fastener length150mm dia 10mm gi , anchor fastener length150mm dia 12mm gi , anchor fastener length150mm dia 16mm gi , nut bolt length 1inch dia 6 mm , counter bolt 8mm, allenkey type, with lock nut , eye bolt for centering arm , spring,159a533,kosncris pt head , ss rod of gd or pt base , ss block of gd or pt base , linear bearing , optical cable for bar code sensor , automatic hot air sealing head , pneumatic cylinder size 500mmx50 norgan , 50 dia sealkit norgren , 50 dia sealkit janatics , solenoid coil for kosan filling scale- smc make , lpg hose of length 1 m , lpg hose of length 1.5 m , lpg hose of length 0.5 m , pencil sensor , rivet type conveyor chain , rod of kosan filling gun pneumatic type , kosan filling gun cup , dampner or kosan filling gun bush , kosan filling scale leg , lower bell for gd , vibration absorber for gd head , kosan fintec load cell for filling scale 200kg , load cell for jisl adjustment scale 650 kg , manual cvt head,kpot0122 carousel,kosncr , lifter plate for check scale , c channel of conveyor , telescopic boom pipe length 6m dia 1.5inch , drag chain , boom e plate with taflon ss thickness-10mm 1mx1m with taflon 12mm , mark iv display , reflector for kosan carousel , lpg filling gun pneumatic type , pneumatic counter , vacuum or suction indicator
Tender For supply installation & commissioning of cgr/gr angle measurement (digital) test set consisting four items that are - (1) portable battery operated unit (2) optical sensor encoder for angle measurement (2.1) resolution 0.1 degree (2.2) range 360 degree (2.3) shaft dia 10mm (3) adapter shaft with flexible coupling for coupling the encoder to the cgr/gr shaft (4) 4x 40 character lcd display for display of: (i) angle data for cgr1, cgr2, cgr3, r1 & r2 (ii) deviation form reference angle (iii) data q3.0 software to download data to pc for storage [ warranty period: 30 months after the date of delivery ] ]