Get complete information related to latest Flicker Generator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flicker Generator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flicker Generator Tenders.
Tender For supply of venturi for nebulizer, mark 7, peek,1 pk , glass impact beads, mark v vi 7,5 pk , burner cleaning and alignment card, 100 pk , burner air-acytelene mark 7, 1 pk. compatible with mark 7, vi and v spray chamber assemblies , 1 pk , nebulizer capillary kit mark 7 s c, 1 pk , nebulizer block, mark 7 s chamber,1 pk , cobalt standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , copper standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , nickel standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , lead standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , zinc standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , cadmium standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , silver standard solution, 1000 ppm, 0. 1 percent, 500 ml per pk , cobalt coded single element hollow cathode lamp, 1 per pk , zinc coded single element hollow cathode lamp, 1 pk , lead coded single element hollow cathode lamp, 1 pk , copper coded single element hollow cathode lamp, 1 pk , nickel coded single element hollow cathode lamp, 1 pk , graphite tubes for agilent 280 aas duo , 10 pk , vials for gta 120 1. 1ml, 2000 pk , aa spray chamber, mark 7,complete , 1 pk ) /bid number: gem/2026/b/7086618 * /dated: 30-01-2026 & & / bid document1 / 21
Tender For supply of cathode copper foil (cold rolled) is: 191(part iv) - 1980 0. 05(-0. 007) mm thick , gr: amg2 kr7n gost-21488-76 aluminium rod dia 7mm
Tender For procurement of hollow cathode lamps (hcl) for gold (au) and silver(ag) and the electrodeless discharge lamps for cadmium(cd) along with the short cable assembly for the edl for aas(pinaacle 900h) instrument
Tender For corrigendum : electrolyser apparatus (electro chemical analyser) along with platinum iridium electrode for gravimetric analysis of non-ferrous metals and alloys 1.electro chemical analyser technical specification- operates on 230 volts ac 5 amps i/p giving an o/p of 10 amps dc at 15 volts. it has built in solid state bridge rectifier of 15 amps. 2.platinum/iridium 10% wire electrode-outer: 150 mm total height 45 mm cylinder height 45 mm cylinder diameter surface area - 125 sq. cms. approximate weight - 30 gms. inner: 140 mm total height 32 mm cylinder height 32 mm cylinder diameter surface area - 70 sq. cms. approximate weight - 19 gms, along with purity certificate of electrode. others- magnetic stirrer with solid state regulator is provided 2. auto-variable for regulating the electrolysis current. 3. dc voltmeter 0-15 volts, on-off switch, interchanging polarity switch for electrodes cathode and anode, single range dc ammeter of 10 ampere. 4. glass fuse for the main supply. 5. adjustable electrode holder height for all types of electrodes. make: abrol, swiss, raj scientific or similar