Get complete information related to latest Flood Light Fittings Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flood Light Fittings Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flood Light Fittings Tenders.
Tender For providing supplying of various electrification related items year 2025 26 chhotaudepur nagarpalika chhotaudepur. - supplying and erecting led street lightfloodlightfittings with high power white leds wattage of 1watt and above assembled on single mcpcb, efficiency more than 130 lm w and corrosion free high pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics/ lenses with company mark/name engraved or embossed 120 to 300 v,power factor more than 0.95, thd 10 persantage cct 3000 k to 5700k uniformity ratio 0.45 luminaire efficacy 100 lumens watt . led driver efficiency 85 cree osram philips lumileds nichia seoul bridgelux u.s.a. make led used for luminaire. fittings required lm-79 lm-80 certificates note: below description have shown ranges of wattage capacity of led fittings.the engineer incharge may select any wattage capacity between the ranges shown. b 15 to 24 watts, supplying and erecting led street lightfloodlightfittings with high power white leds wattage of 1watt and above assembled on single mcpcb, efficiency more than 130 lm w and corrosion free high pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics lenses with company mark/name engraved or embossed 120 to 300 v,power factor more than 0.95, thd 10 cct 3000 k to 5700k, uniformity ratio 0.45, luminaire efficacy 100 lumens/watt . led driver efficiency 85 cree osram philips lumileds nichia seoul bri dgelux u.s.a. make led used for luminaire. fittings required lm-79 lm-80 certificates note: below description have shown ranges of wattage capacity of led fittings.the engineer incharge may select any wattage capacity between the ranges shown c above 24 to 36 watts, supplying and erecting led street lightfloodlightfittings with high power white leds wattage of 1watt and above assembled on single mcpcb, efficiency more than 130 lm w and corrosion free high pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics lenses with company mark/name engraved or embossed 120 to 300 v,power factor more than 0.95, thd 10 cct 3000 k to 5700k, uniformity ratio 0.45 luminaire efficacy 100 lumens/watt . led driver efficiency 85 cree osram philips lumileds nichia seoul bridgelux u.s.a. make led used for luminaire. fittings required lm-79 lm-80 certificates note: below description have shown ranges of wattage capacity of led fittings.the engineer incharge may select any wattage capacity between the ranges shown. f above 60 watts to 90 watts, supplying and erecting led street lightfloodlightfittings with high power white leds wattage of 1watt and above assembled on single mcpcb, efficiency more than 130 lm w and corrosion free high pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics/ lenses with company mark name engraved or embossed 120 to 300 v,power factor more than 0.95, thd 10 cct 3000 k to 5700k, uniformity ratio 0.45, luminaire efficacy 100 lumens watt . led driver efficiency 85 cree osram philips lumileds nichia seoul bridgelux u.s.a. make led used for luminaire. fittings required lm-79 lm-80 certificates note: below description have shown ranges of wattage capacity of led fittings.the engineer incharge may select any wattage capacity between the ranges shown g above 90 to 120 watts, repairing of existing indoor led light fixture(tube light/panel light/spot light/strip light/decorative wall lights etc as per sample )by suitable driver 2 kv according to led pcb as per requirement of following rating wattage capacity . (g)50-80 watt capacity, repairing of existing indoor led light fixture(tube light/panel light/spot light/strip light/decorative wall lights etc as per sample )by suitable driver 2 kv according to led pcb as per requiremen
Tender For maintenance of street lighting on various roads in various sectors at u.t chandigarh (replacement of defunct led floodlightfittings, switchgear and other allied accessories of existing high masts installed in dhanas colony at u.t chandigarh).
Tender For maintenance of e&m services at supreme court of india new delhisubwork/packages:providing additional emergency lights in court rooms, chambers
Tender For supply of 12 v, 7 ah sealed maintenance free lead acid battery for emergency lights of ac and non- ac coaches. the battery should be fit in the rdso drawing no. rdso/ pe/sk/tl/0180 - 2016 (rev.0) of sheet 1 & 2. the make of the battery be m/s. exide / tafe (amco)/ amararaja/ hbl as per rdso specification no. rdso /pe / spec/ ac/ 0180-2016 (rev.0).
Tender For tender for supply of starter lead acid battery capacity 8v, 290 ah low maintenance for mg locos confirming to rdso spec. no. elps/spec/tl/0001-98 (rev-0) with amendment no. 1 complete with inter cell connector and fasteners. initial charging of battery required at the time of supply. firm should have type test approval confirming to rdso spec. no. elps/spec/tl/0001-98 (rev-0), 12v, 7ah sealed maintenance free lead acid battery for emergency lights for lhb ac and non ac coaches. the battery should be fit in the rdso's drawing no. rdso/pe/sk/tl/0180-2016(rev.0), 12v, 7ah sealed maintenance free lead acid battery for emergency lights for lhb ac and non ac coaches. the battery should be fit in the rdso's drawing no. rdso/pe/sk/tl/0180-2016(rev.0), 12v, 7ah sealed maintenance free lead acid battery for emergency lights for lhb ac and non ac coaches. the battery should be fit in the rdso's drawing no. rdso/pe/sk/tl/0180-2016(rev.0), sealed maintenance free 7ah 12v battery unit for automatic smoke/ fire detection with alarm system installed in lhb & icf ac coaches. make: exide cs 7-12 smf or amaron or similar, 12 volt 42 ah battery smf battery of any reputed make ex:-exide, amaron, liveguard or similar, 72988964 hand hacksaw blade, type a, size 300 x 12.5mm x 0.63mm x 1.8 mm, specification is:2594/2003 hs with amendment (i to v) or latest make: eastman is accepted., emergency battery charger single phase 50 hz for eog type lhb ac coaches as per rcf specification no. edts-163, rev-c, corrigendum-5 and as per rcf drawing no. sked-350 (on board) type-1. specn: edts-163 cor-1
Tender For provision of post top type fittings and floodlightfittings behind the compound wall of fth area and the area between in front of vi-2 has been taken up for area development at hvf estate