Tender For installation of various instruments at lakhanka and hamirpara irrigation scheme - providing, supplying, installing, testing, and commissioning of a v-notch weir (mechanical flowmeasuringdevice) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anticorrosion finish. complete in all respects as directed by the engineer-in-charge. (1) 90° v-notch-20 x 40 secticin 15 lit/sec , providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in- charge. , providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc. c) concrete grade 1:2:4 and msa-40mm(graded)
Tender For installation of various instruments and monitoring system at vadi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir mechanical flowmeasuringdevice) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For installation of various instruments and monitoring system at thebi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir (mechanical flowmeasuringdevice) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For installation of various instruments at raidy & dhataravdi-1 irrigation scheme - item no.1:- providing, supplying, installing, testing, and commissioning of a v-notch weir (mechanical flowmeasuringdevice) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss- 304/ss-316 plate with thickness of 3-5 mm, and be suitable for measurement ranges of approximately 0-50 l/s depending on notch angle. the weir shall have ±1% fullscale reading accuracy, operate under 5-100% humidity, temperature -20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge. (1) 90° v-notch-20 x 40 secticin 15 lit/sec , item no.2:- providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge. , item no.3:- providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks, centering, scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc. (c ) concrete grade 1:2:4 and msa-40 mm(graded)
Tender For purchase of instruments/equipment s blood pressure monitor led instrument manual (mercury free), digital thermometer for refrigerator measures the refrigerator or freezer temperature from -50 to 70c, includes a one-meter fridge sensor cord accuracy of +/-1c over the full range, ilr alcoholic thermometer (-30 c to + 50 c) coloured alcohol in glass column noncorrodible plastics or metal case. the glass column must be protected against breakage and strongly supported so that the column cannot be displaced more than 0.5 mm vertically with respect to the scale, easy to hang, stature meter 200cm wall mounted, material: plastic, metal band
Tender For purchase of instruments/equipment's blood pressure monitor led instrument manual (mercury free), digital thermometer for refrigerator measures the refrigerator or freezer temperature from -50 to 70c, ilr alcoholic thermometer, digital thermometer for refrigerator, stature meter 200cm wall mounted material: plastic, metal band, fetal doppler/heart rate monitor, mid - upper arm circumference (muac tape)