Web Analytics Made Easy - StatCounter

Flue Tenders

Get complete information related to latest Flue Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Flue Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Flue Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :42063030 Due date: 06 Oct, 202506 Oct, 2025 1.00 Crore
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p

CTN :42132622 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For mtps-i -bm-unit-iii- aoh-2025-26 - flue gas duct - ‘a’ & ‘b’ sides-patch up works and other repair works between aph out let to esp inlet.

Central Government/Public Sector

CTN :42133661 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For scope of work (sow) as mentioned in tender and schedule of work( 12 )items as given below ,[1] remvng,muck from hec cooling tower basin 40.000 m3,[2] remvng,muck from occ cooling tower 40.000 m3,[3] remvng,muck&scale,sst pit 3nos 1500.000 m3,[4] remvng,muck&scale 35.000 m3,[5] remvng,muck from occ pump basin 35.000 m3,[6] remvng,muck&scale,spph pit&basin 30.000 m3,[7] serv bunker cleaning 1.000 le,[8] remvng,sticky dust 300.000 m3,[9] remvng,sinter fine dust 200.000 m3,[10] remvng,sticky flue dust 200.000 m3,[11] remvng,sticky flume dust 100.000 m3,[12] remvng,debris&strl 200.000 m3

State Government

CTN :42133782 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For work of cleaning & repairing of primary / secondary air ducts & flue gas ducts from economizer outlet to chimney inlet during short shutdown of unit-5 at bhusawal tps.

Central Government/Public Sector

CTN :42134355 Due date: 14 Oct, 202514 Oct, 2025 NA
Tender For providing of custom bid for services - 200144435 service contract for overhauling of air and flue gas ducts of boiler of 5x 210 mw units and 1x500 mw unit for two years at ntpc unchahar

corporations/Associations/Others

CTN :42135926 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For mtps i bm unit iii aoh 2025 26 flue gas duct a and b sides patch up works and other repair works between aph out let to esp inlet

State Government

CTN :42136907 Due date: 28 Oct, 202528 Oct, 2025 49.45 Lacs
Tender For supply and application of zinc rich paint for flue gas duct structure from air preheater out to chimney inlet in boiler unit no. 3 at sikka tps. - epoxy zinc rich anti-corrosion paint (90 percentage - 95 percentage zinc), zinc primer (epoxy base - 60 percentage zinc), thinner (g.p.) suitable for epoxy paint, charges for the application of zinc rich paint on flue gas duct structure from aph outlet to chimney of boiler unit no. 3 at sikka tps as per scope of works and instruction of eic

Private Sector

CTN :42141342 Due date: 30 Oct, 202530 Oct, 2025 NA
Tender For supply of limestone for wet limestone-based flue gas desulphurisation (fgd) plant installed at nabha power limited

State Government

CTN :42116154 Due date: 08 Oct, 202508 Oct, 2025 NA
Tender For work of flow modulation in flue gas ducts by computational fluid dynamics during coh of 1x250 mw unit-8 tps parli-v.

Central Government/Public Sector

CTN :41404172 Due date: 10 Oct, 202510 Oct, 2025 NA
Tender For corrigendum : supply of of datasheet ref-gate-act data-adanig rev-00 , l156715757701023 - l156715757701024 -elec atuator for id fan inlet gate as per s-no 9 - 10 of datasheet ref-gate-act data-adanig rev-00 , l156715757701025 - l156715757701026- elec atuator for id fan outlet gate as per s-no 11 - 12 of datasheet ref-gate-act data-adanig rev-00 , l156915757701001 - l156915757701002- elec atuator for sa ah outlet damper as pers-no 1 - 2 of datasheet ref- damp-act- data-ora-adanid2 rev-00- , l156915757701003 - l156915757701004 - elec atuator for scr bypass damper as per s-no 3 - 4 of datasheet ref- damp-act- data-ora-adanid2rev-00- , l156915757701005 - l156915757701006 - elec atuator for sa scaph inlet damper as per s-no 1 - 2 of datasheet ref-damper-act data-adanidrev-00- , l156915757701007 - l156915757701008 -elec atuator for sa scaph outlet rh damper as per s-no 3 - 4 of datasheet ref-damper- act data-adanid rev-00- , l156915757701009-elec atuator for sa ah inlet rh damper as pers-no 5 of datasheet ref-damper-act data -adanid rev-00- , l156915757701010-elec atuator for pa ah inlet rh damper as per s-no 6 of datasheet ref-damper-act data -adanid rev-00- , l156915757701011 - l156915757701012-elec atuator for pa ah outlet damper asper s-no 7 - 8 of datasheet ref-damper-act data-adanid rev-00- , l156915757701013 - l156915757701014- elec atuator for flue gas ah outlet rh damperas per s-no 9 - 10 of datasheetref- damper-act data-adanid rev-00- , l156915757701015 - l156915757701016 -elec atuator for fd fan outlet gate as per s-no 1 - 2 of datasheet ref-gate-act data- adanig rev-00 , l156915757701017 - l156915757701018 - elec atuator for esp inlet gate as per s-no 3 - 4 of datasheet ref-gate-act data-adanig rev-00 , l156915757701019 - l156915757701020 -elec atuator for esp outlet gate as per s-no 5 - 6 of datasheet ref-gate-act data-adanig rev-00 , l156915757701021 - l156915757701022 -elec atuator for pa fan outlet gate as per s-no 7 - 8 of datasheet ref-gate-act data- adanig rev-00 , l156915757701023 - l156915757701024 - elec atuator for id fan inlet gate as per s-no 9 - 10 of datasheet ref-gate-act data-adanig rev-00 , l156915757701025 - l156915757701026- elec atuator for id fan outlet gate as per s-no 11 - 12 of datasheet ref-gate-act data-adanig rev-00 , l157115757701001 - l157115757701002- elec atuator for sa ah outlet damper as pers-no 1 - 2 of datasheet ref- damp-act-data-ora-adanid2 rev-00- , l157115757701003 - l157115757701004 - elec atuator for scr bypass damper as per s-no 3 - 4 of datasheet ref- damp-act-data-ora-adanid2rev-00- , l157115757701005 - l157115757701006 - elec atuator for sa scaph inlet damper as per s-no 1 - 2 of datasheet ref-damper-act data-adanidrev-00- , l157115757701007 - l157115757701008 -elec atuator for sa scaph outlet rh damper as per s-no 3 - 4 of datasheet ref-damper-act data-adanid rev-00- , l157115757701009-elec atuator for sa ah inlet rh damper as pers-no 5 of datasheet ref-damper-act data -adanid rev-00- , l157115757701010-elec atuator for pa ah inlet rh damper as per s-no 6 of datasheet ref-damper-act data -adanid rev-00- , l157115757701011 - l157115757701012-elec atuator for pa ah outlet damper asper s-no 7 - 8 of datasheet ref-damper-act data-adanid rev-00- , //bid details 2 / 80 datasheet ref-damper-act data-adanid rev-00- , l157115757701013 - l157115757701014- elec atuator for flue gas ah outlet rh damperas per s-no 9 - 10 of datasheetref-damper-act data-adanid rev-00- , l157115757701015 - l157115757701016 -elec atuator for fd fan outlet gate as per s-no 1 - 2 of datasheet ref-gate-act data-adanig rev-00 , l157115757701017 - l157115757701018 -elec atuator for esp inlet gate as per s-no 3 - 4 of datasheet ref- gate-act data-adanig rev-00 , l157115757701019 - l157115757701020 -elec atuator for esp outlet gate as per s-no 5 - 6 of datasheet ref-gate-act data- adanig rev-00 , l157115757701021 - l157115757701022 - elec atuator for pa fan outlet gate as per s-no 7 - 8 of datasheet ref-gate-act d
 Loading, Please wait...