Tender For supply of multimode microplate reader microplate reader detection modes uv/vis absorbance fluorescence intensity (incl. fret) luminescence (flash and glow) - incl. bret time-resolved fluorescence tr-fret fluorescence polarization measurement modes top and bottom reading endpoint and kinetic sequential multi- excitation sequential multi-emission spectral scanning (absorbance, fluorescence, luminescence) radiometric measurements well scanning microplate formats 6- to 384- well plates, user-definable lvis plate with 16 low volume micro spots (2 l) microplate carrier robot compatible light source high energy xenon flash lamp detectors low-noise photomultiplier tube ccd spectrometer wavelength selection dual linear variable filter (lvf) monochromators linear variable dichroic mirror: separates excitation and emission lvf monochromators optical filters: excitation and emission slides hold up to 5 filters each lvf monochromators + optical filters: use one for excitation and the other for emission uv/vis absorbance spectrometer: full spectra or 8 discrete wavelengths in <1 sec/well optical filters excitation and emission slides for up to 4 filters each for monochromator units, and for up to 5 filters each for filter-only units optical path top and bottom: free-air optical light path guided by motor-driven mirrors and dichroics z- adjustment automatic focal height adjustment (0.1 mm resolution) spectral range filters fi, lum, trf, fp, tr-fret: 240 - 740 nm lvf monochromators fi, lum: 320 - 740 nm linear variable dichroic 340 - 740 nm spectrometer abs: 220 - 1000 nm; wavelength precision: 0.5 nm sensitivity * /bid number : gem/2026/b/7680619 + /dated: 18-06-2026 ' ' / bid document 1 / 8
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : supply of spares pf lss model no quantulus 1220 and gct 6200 e e - sts-photomultiplier ,must test 663f, photomultiplier tube 1220 hsn code -85402000 part no-11760032 for quantulus 1220 , cogged belt- synchroflex- 6t 2-5- 285 ks35 hsn- 39269099 part no-11350044 for quantulus 1220 model , cogged belt- synchroflex- 6t 2-5-950 ks3 hsn- 39269099 part no-11350055 for quantulus 1220 model , assembly, tab puller cell must test hsn - 90309090 part no-7400374 for gct 6220 model , pcb las motor driver board hsn - 90309090 part no-71011615 for gct 6220 model , assembly, rear wall pin drive hsn - 90309090 part no-7400369 , assembly, front wall pin drive hsn - 90309090 part no. - 7400370 , corner sensor hsn - 90279090 part no. - 7101141 for gct 6220 model , wall sensor assy. hsn - 90279090 part no- 5074993 for gct 6220 model , prog plug sens hsn - 90279090 part no-7101146 for gct 6220 model , s-hldr sensor hsn - 90279090 part no-7101147 for gct 6220 model , elvtr body assy, field rplcmt,. hsn - 90309090 part no-7601227 for gct 6220 model , elvtr pedestal, field rplcmt, hsn- 90309090 part no- 7601222 for gct6220 model ) /bid number : gem/2026/b/7388464 * /dated: 17-04-2026 & & / bid document 1 / 26