Get complete information related to latest Fluorescent Choke Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fluorescent Choke Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fluorescent Choke Tenders.
Tender For supply of ip based cctv surveillance system and dedicated fiber optic network backbone connectivity d d -four mp fixed bullet camera with forty mtr , four mp anpr camera with thirty mtr ir , four mp wdr thirty two x ir network ptz camera one hundred eighty mtr , thirty two ch four k nvr , ten tb surveillance hdd , supply and installation of twenty four port layer two and switch with ten giga uplink , supply of ten port l two managed switch incl eight nos of gigabit poe and ports and two nos combo , one g single mode transceivers , two kva li ups with built in batteries , six hundred va ups with built in batteries , cat six twenty three awg solid bare copper conductor uutp unshielded hdpe insulation armoured cable , twenty four core single mode armoured fiber cable , six core single mode armoured fiber cable , fiber patch cord sm , twelve port rack mounted liu with single mode lc upc pigtail and coupler , outdoor enclosure , six u rack , three core copper armoured cable , rj forty five connector , termination junction box , angle for fixing ptz camera , customized gi camera box with gi bracket , spd for lighting or power surge protection , electrification including electric wire switch or socket and related accessory , cat six cable laying charges , overhead fiber optic cable laying charge with gi wire , termination and splicing charges of fibre optic cable , supply installation testing and commissioning
Tender For high availability single section digital axle counters (hassdac) with dual sensor system as per rdso/spn/177/2012 version 3 or latest. this includes the supply of high frequency web mounting type tx coil/rx coil, vr/pr box duly wired, vital relays, pr relays, clamp with deflector plates & hardware. dual display reset box with auto resetting facility, surge voltage protection devices and filter card to be mounted on din rail etc as per oem for complete intallation & testing & commissioning of (hassdac) system note; one set of hassdac system will include equipment required to monitor one up line or one dn line of a full block section between two stations. inspection rdso
Tender For supply of electrical materials for day to day maintenance of ei at balak ram hospital. - supply of 6- 32 amps rating, sp mcb, c curve, 10 ka breaking capacity., supply of 6- 32 amps rating, dp mcb, c curve, 10 ka breaking capacity., supply of 40 amp, 2 pole isolator ., supply of 63 amp, 2 pole isolator ., supply of 63 amp, 4 pole isolator ., supply of 100 amp, 4 pole isolator ., supply of 40 amp rating 2 pole rccb, 30 ma ., supply of 63 amp rating, 4 pole rccb, 30ma ., supply of 20 a, spn, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure., supply of 25 mm dia isi marked, pvc conduit, supply of pvc batten / angle holder., supply of 2+6 way, spn, single door, mcb db, supply of 2+2 way, spn, single door, mcb db, supply of 4 way (4 + 12), tpn, mcb db, double door horizontal type., supply of 6 way (4 + 18), tpn, mcb db, double door horizontal type., supplying of led recessed/surface down lighter (round /square/ rectangular) smd type of following body material with pmma and prismatic diffuser and construction as per is : 10322 with driver as per the requirement with driver efficiency >85%, operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80, ugr (unified glare rating) 19, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), life time of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report, cct 3000 k / 4000 k / 5700 k / 6000 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 and 120 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body including trim with aluminium reflector. 12 -15 watt, supplying of panel light 2x2 ft., of following body material and construction as per is : 10322 with driver as per the requirement with driver efficiency >85%, operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection,thd 10% , p. f. 0.95, ip20, cri >80, ugr (unified glare rating) 19, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends ,cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin), sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate (t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required withminimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by eng
Tender For corrigendum : supply of electrical items for repair and maintenance of electrical installation at iiser bhopal - supply of 22 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 5000k only. (make: havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of 10 (+/-2) watt led tube light betten t-5 made of aluminium/pc body with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt, and p.f>0.9. the cct of led used should be between 5700k to 6000k only. (make: havells/crompton/philips/wipro/orient/panasonic/jaquar)., supply of 38 (+/-2) watt recessed mounted 2x2 feet led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of 38 (+/-2) watt surface mounted 2x2 feat led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f.> 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar)., supply of surface mounted ceiling light 18 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only (make:-havells/crompton/philips/ wipro/orient/ panasonic/jaquar)., supply of recessed mounted (11) ceiling light 22 (+/-2 watt led light fitting with pc diffuser with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and p.f 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar), supply of surface mounted motion sensor ceiling light 10 watt led light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100lm/watt and pf>0.9, up to 2 kv surge 6000k to protection. the cct of led used should be between (make-havells/crompton/philips/wipro/orient/ panasonic/jaquar) 6500k only, supply of 10 watt (+/-2 watt) bulkhead light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up 10 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make:-havells/crompton/philips/ wipro/orient/ panasonic jaquar), supply of 10 watt track (study lamp) light fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 im/watt and p.f>0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of 45 watt (+/-2 watt) streetlight fitting with inbuilt driver for proper driving of leds. the minimum system lumen output 100 lm/watt and p.f. 0.9, up to 2 kv surge protection. the cct of led used should be between 6000k to 6500k only. (make: havells/crompton/philips wipro/orient/ panasonic/jaquar), supply of aesthetically designed post top led luminaire smd of 40 w+ 5%, rated voltage 240v ac, 50 hz. ip 65 protection, system lumen efficacy > 90 lumens/w, voltage range 140-270 v ac, pf 20.95, cct: 5700k-6500 k, thd-10%, cri->70, operating temperature 0°c to 50°c, (make havells/crompton/philips/wipro/orient/panasonic/ jaquar)., supply of aesthetically designed tripod style inverted pyramid bollard of 0.8m to 0.9m heighted led light of 10 (+/-) 2 w at 230 v ac operation, ip 65 protection, voltage range 150-260 v ac, pf>0.9, cct: 5400k 6500k, surge protection 4.5kv made up of aluminium casti
Tender For corrigendum : supply, testing and commissioning of smps based integrated power supply (mini ips) systemfor lc gate in re area with 200ah vrla battery (55+5 cells) as per rdso specification no.rdso/spn/165/2023 ,version 4.0 or with latest amendment/specification complete set with surge protection devices( in separate wall mountable spd box), status minitoring panel , cable for connecting ips to battery bank, tool kit, all spares as per rdso specification, all optional modules , user instruction manual, etc and commissioning of ips system at lc gate in accordance with rdso letter no. sts/e/ips/genl. dated.03.04.2008 or latest.[ warranty period: 30 months after the date of delivery ]
Tender For supply of smps powerplant rectifier modular type input 3 phase output 54v dc 100a module 4 plus 1 with rack and remote access function like smtp for integration to ibms set , li ion battery 100ah 5 nos 48 v nominal 42 to 54 v dc with rack and remote access function like smtp for integration to ibms set , surge protection in eb panel room part of power plant , ac isolater for power plant 100a or 200a 4 pole inside power plant room or battery room , gi cable tray hanging type with supporting rods nuts and bolts 1 ft width 5 cm height trey for ac main and dc distriboution , cable 4 core for ac main distribution between eb main and lt panels dg to main lt panel , earthing dc 2 nos 0 point 5 ohm with interconnecting earth strips 02 termination bus bar nos , ac earth provisioning in smps pp room and slte room , copper earth strip bus bar , industrial or split or tow ac 1 point 5 t 3 nos for slte and 1 point 5t 03 nos for power plant roomer 5 star inverter copper with associated mcb box 16a , fire extinguisher 1set , ibms with full integration and master control room fire sensor cctv access control rodent water leakage temperature intruder alarm system etc for rooms where it is not , other associated works like wiring providing sockets switches fuse boxes cabling casing concealing lighting etc lot , uninterrupted ac power supply 5kva , installation of ibms master control room , antistatic floor at minicoy , false ceiling at minicoy , antistatic floor at androth , partition with door access at androth , false ceiling at androth
Tender For supply of layer 2 access switch non poe,layer 2 access switch poe,sfp pluggable transceiver,monitoring and analyzer,network policy controller,12u rack enclosures networking,zero u pdu,aggregated power management unit,video conferencing camera,microphone with speeker,edge computing device,h res av cable,high speed data and control cable,storage media centre,multi viewer with av switching and control,dome camera,16 channels nvr,access control system,power conditioning and surge protection unit,cat 6 information outlet,cat 6 u-utp patch panel,cat 6 u-utp patch cord 1 mtr,cat 6 uutp patch cord 2 mtr,cat 6 u-utp cable,cat 6 cable for outdoor,fiber optic patch cord lc-sc,single mode fiber cable,splice closure for optical fiber cable,pvc channel 25mm,pvc channel 50 mm,pvc copper cable,power socket with electrical switch,cable pulling pit,underground trenching, laying of foc and restoration of ground,installation, testing, commisioning and integration
Tender For survey investigation, design, supply, installation, testing and commissioning of tank filling scheme consisting of construction of intake channel, forebay, jack well cum pump house, power supply including terminal bay, transmission line, electrical substation, rising main, distribution network, delivery chamber, gravity main network, various types of valves, receiving chambers, staff quarters, surge protection system for filling of 22 tanks in kambadal hosur and surrounding villages by lifting 0.19 tmc of water from bhadra river near gonibeedu village of bhadravathi taluk, shimoga district including operation and maintenance for a period of 5 years after successful completion of work for kambadal hosur tank filling scheme on turn-key basis