Web Analytics Made Easy - StatCounter

Focus Group Discussion Tenders

Get complete information related to latest Focus Group Discussion Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Focus Group Discussion Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Focus Group Discussion Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45598447 Due date: 06 Jul, 202606 Jul, 2026 3.00 Lacs
Tender For corrigendum : pest control service on contract basis at research and development laboratory, ambattur, chennai

CTN :45679443 Due date: 01 Jul, 202601 Jul, 2026 3.58 Lacs
Tender For construction of the laboratory building for central power research institute at naya raipur loc village-banjari layer-2 naya raipur c.g. s.h. co temperature rise test bay impulse test bay routine t energy meter testing & cyber security building electric sub-station dee tube well 2 nos. & recharve pit 1 no. underground sump of capacity 50,000 litres with pump house internal road with rcc drain including service and horticulture operation etc.s.h. providing pump set.

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

Central Government/Public Sector

CTN :45648860 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For providing of custom bid for services - job contract for agricultural service at sisal research station, bamra, odisha

CTN :45483229 Due date: 23 Jun, 202623 Jun, 2026 30.07 Crore
Tender For corrigendum : planning, designing and construction multidisciplinary research centre (mrc) (basement plus g plus 2) at rie, mysore including internal water supply, sanitary installations, civil external service connections, internal electrical installations, electrical external service connections, fire fighting and fire alarm system, pressurized mechanical ventilation system, lightning conductors, lifts, overhead water tank, ups,ip based cctv system, lan and networking system, and illuminated signages, vrv/vrf system, ro water purifier, lab equipments (wall table, sitting table, storage cabinet, modular fume hood etc) development works i/c levelling, retaining wall ramps, footpath, external sewerage, storm water drains, rain water harvesting (rwh), street lighting with led, consultancy services for planning and designing of project inclusive of architectural drawings, structural, mep services and electrical devp services etc, all complete on engineering, procurement and construction (epc mode 1)

CTN :45612698 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For providing food and beverages (canteen service contract) at the pu centre for post graduate and research studies, dharmapuri

Central Government And Public Sector

CTN :45358579 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For corrigendum : providing of biomedical waste management service - weight basis - lifting, transportation, treatment, disposal; research instiute; injections & needles, face mask, ppe kits, needle cutters, gloves, broken glass, scalpels, medicines, chemical disinfectants

CTN :45626904 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For providing of manpower outsourcing services - fixed remuneration - senior graphic designer; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - research assistant; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - research associate; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - documentation assistant; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - accounts assistant; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - library assistant; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - data entry operator; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing services - fixed remuneration - hindi typist; as per annexure 1 of atc; as per annexure 1 of atc,manpower outsourcing service

CTN :45578822 Due date: 22 Jun, 202622 Jun, 2026 3.58 Lacs
Tender For construction of the laboratory building for central power research institute at naya raipur loc village-banjari, layer-2, naya raipur (c.g.) (s.h.:- construction of temperature rise test bay, impulse test bay, routine t energy meter testing & cyber security building, electric sub-station, deep tube well (2 nos.) & recharge pit 1 no. underground sump of capacity 50,000 liters with pump house, internal road with rcc drain including service and horticulture operation etc.s.h.- providing pump set.

Central Government/Public Sector

CTN :45293310 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - research institute; real water purification system; service provider
 Loading, Please wait...

Connect us via What's Up