Get complete information related to latest Forane Gas Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Forane Gas Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Forane Gas Tenders.
Tender For supply of servicing and repairing of hvac system - de scaling of condenser , sitc of key ped , sitc of of sm2 card , sitc of of york chiller resistance , sitc of oil filter , refrigerant gas , condenser oil , motor , servicing of cooling tower , pvc eliminator , pvc end cap , eliminator jali , frp compound , frp motor cover
Tender For supply of hfc refrigerant gas r- 407c [having chemical name difluoro methane, penta fluoro ethane, 1,1,1,2-tetra fluoro ethane and chemical formula ch2f2/ch3chf2/ch3ch2f] suitable for rmpu in lhb type ac coaches (45 kg gas in each cylinder).
Tender For tender for supply of bulb 24v/70w p.no- 955eg02137 , bulb (halogen) p.no- 452eg11249 , refrigerant gas p.no.- r134a , tublar type copper lug 95 sq mm p. no.- clug95 , tublar type copper lug 95 sq mm p. no.- clug95
Tender For supply of supply of 50 hp vrf or vrv outdoor unit , supply of indoor unit floor standing dx type ahu. capacity of each unit is 50 hp , supply installation testing and commissioning of refrigerant pipes. payment shall be as per actuals. , supply and installation of remote status indication panel , supply and installation of switch panel and wiring of equipment , supply of 4 core 16 sqmm copper shielded armoured cable odu to mcb. payment shall be as per actuals. , supply of 4 core 10 sqmm copper shielded armourmed cable ahu to switch panel. payment shall be as per actuals. , supply of control cable, 3 core, 1. 5 sq. mm, suitable for non-polarity multiplex transmission system, laid in pvc piping and clamp. payment shall be as per actuals. , supply of refrigerent gas , intallation testing commissioning of 3x50 hp vrf or vrv outdoor unit and ahus , nitrogen flushing pressure testing vaccumising and commissioning the system , modification of duct , supply fabrication installation of ms base frame or platform for odus , supply and installation of canvas connection , supply and installation of g. i perforated cable tray with top cover with supports , dismantling and shifting of existing ac plants , training , miscellaneous civil works , any other supply or works necessary for satisfactory completion of the entire job
Tender For supply of refrigerant gas r-407c confirming to is: 5610/1993, re affirmed-2006 or latest if any, in 45 kgs capacity standard cylinders on non returnable basis by filling refrigerant gas r-407c. note: gas must be filled in company's sealed refrigerant gas cylinders indicating cylinder weight, net weight of the gas & gross weight, date of refrigerant gas along with test certificate of gas & cylinder, otherwise subject material is liable for rejection.
Tender For supply of spares- refrigerant gas r407c with cylinder qty: 07 kg per cylinder shaft seal cover, part no.- , ac926100076, make voltas por ac plant compressor model no. 05066-s , shss. assly with ring, part no ac926101800, make voltas for ac plant compressor model no. 05066-5 , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model-ucp 205 for ahu of switch yard control room ac package , v belt a-28 , seal cover plate , p.no:ac926100076 make: voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101800 make: voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make voltas for ac plant compressor model no:05086 , v belt b 85 , , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code.0232500s for blue star make package ac.5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model no: dohss, capacity: 8.5 tr make voltas for 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/4??) , ratchet wrench (4-size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-98
Tender For replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to be deposited i