Get complete information related to latest Forensic Workstation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Forensic Workstation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Forensic Workstation Tenders.
Tender For arainpura block: gharaunda (part) panchayat: arainpura dist.: karnal annual maintenance work for water supply. - computer items - computer monitor, keyboard and mouse wireles, microtek 1 kva ups
Tender For items - equipment accessories, abg machine ( as per model , make), 1. all card (as per req), 2. printing papers rolls (as per req), 3. cuvettes (as per req), 4. refill solution 100 ml (as per req), 5. controls, 6. syringe tips, 7. cleaning solution 100 ml, anesthesia machine ( as per model , make), 1. soda lime 5kg , 2. mask, 3. breathing circuits, 4. anesthesia agents, 5. bains circuit, 6. flow sensor, 7. oxygen sensor, 8. isoflurane inhaler 100ml, blood bank refrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, defibrillator ( as per model , make), 1. pads, 2. jelly 100 gm, 3. paper, 4. leads, 5. battery, 6. bp cuff adult / neonation, 7. disposable electrodes, elisa reader washer ( as per model , make), 1. printing papers rolls (as per req), 2. cuvettes (as per req), 3. refill solution 100 ml (as per req), oxygen concentrator ( as per model , make), 1. o2 tubing (as per req), 2. face masks (as per req), suction machine ( as per model , make), 1. transparent cannula, 2. suction cannula, 3. holder, 4. filter, 5 jaar, 5. tube, x-ray machine ( as per model , make), 1. battery in hf, ventilator ( as per model , make), 1. disposable masks, 2. breathing circuits, 3. hme filter, 4. bacterial filter, 5. oxygen sensor, 6. flow sensor, 7. battery, microscope ( as per model , make), 1. immersion oil, deep freezer, walk in freezer, walk in cold room, walk in cold room, ice lined refrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, 6. battery, usg machine ( as per model , make), 1. ups batteries, 1. jelly 100 gm, 2. thermal paper roll (as per requirement), autoclave ( as per model , make), 1. printer ribbon and rolls, 2. b & d test pack, 3. biological indicators, 4. water quality should be as per oem recommendations otherwise, 5 heating elements will be consumable., audiometer ( as per model , make), 1. ear tips, 2. electrodes, others items, multipara monitor lead ( as per model , make ), multipara monitor stand ( as per model , make ), multipara monitor prob ( as per model , make ), tabletop pulse oxymeter prob ( as per model , make ), tabletop pulse oxymeter adaptor ( as per model , make ), autoclave biological indicators tape ( as per model , make ), ecg machine lead ( as per model, make), ecg electrodes, nibp cuff (as per model , make ), silicone suction tube per meter, spo2 probe neonatal as per department equipment, spo2 probe pediatric as per department equipment, spo2 probe adult as per department equipment, stethoscope ( adult) dr. morepen, bpl, diamond
Tender For supply of high expansion foam generator unit , portable water cum foam monitor , stored pressure type 06 kg map-90% portable fire extinguisher
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam