Get complete information related to latest Forwarding Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Forwarding Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Forwarding Pump Tenders.
Tender For repair to water supply distribution network including disinfection of water supply at various pump house and repair to various submersible pump, booster electric control system at af station chandigarh under ge (af) chandigarh
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For supply of coupling for boiler and boiler auxiliaries d d - sc110160186 pin bush coupling rb 116 4 motor side bore dia42mm key wxh 12x6 pump side bore dia22mm key wxh 8x6 ldo unloading pump c bore type finished bore , sc110160185 pin bush coupling rb 116 4 motor side bore dia42mm key wxh 12x6 pump side bore dia24mm key wxh 8x6 aux pressurizing pump a or b bore type finished bore , sc110160184 pin bush coupling rb 116 4 dirty oil pump a or b bore type pilot bore , sc110160182 pin bush coupling rb 144 6 motor side bore dia55mm key wxh 16x8 pump side bore dia32mm key wxh 10x6 ldo unloading pump a or b bore type finished bore , sc110160179 pin bush coupling rb 144 6 motor side bore dia55mm key wxh 16x8 pump side bore dia28mm key wxh 8x6 ldo pressurizing pump a or b or c or d bore type finished bore , sc110160180 pin bush coupling rb 144 6 drain oil pump bore type pilot bore , sc110160183 pin bush coupling rb 125 4 motor side bore dia42mm key wxh 12x6 pump side bore dia28mm key wxh 8x6 mldo unloading pump d bore type finished bore , sc110160178 pin bush coupling rb 162 6 motor side bore dia65mm key wxh 18x8 pump side bore dia48mm key wxh 14x7 mldo unloading pump a or b or c and mldo forwardingpump , sc110160189 jaw flex coupling l110 mill lop bore type pilot bore , sc110160187 jaw flex coupling l095 mill hop and raph lop bore type pilot bore , sc110160181 jaw flex coupling l100 pa fan lop and cop fd fan lop and cop id fan lop and cop bore type pilot bore , sc110160188 gear coupling lgf 101 103 by 140 feed pump bore type pilot bore , sc110160177 pin bush coupling size rb 198 10 raph water wash bore type pilot bore , sc110160175 spacer type coupling size 80 250 140 seal air fan bore type pilot bore , sc110160176 resilient type coupling frc 11 type z fd fan bore type pilot bore
Tender For annual rate contract for repair of hc pumps, booster motor shaft rotor and submersible motor shaft rotor and bushes, submersible pumps submersible pump v6 installed at various pumping station in jal shakti phe division akhnoor - 1. annual rate contract for repair of hc pumps installed at various pumping stations in jal shakti (phe) division akhnoor. a) ksb make, b) fnc make, c) mather platt make, d)rkb make. 2. annual rate contract for repair of booster motor shaft rotar & submersible motor shaft rotor and bushes installed at various pumping stations in jal shakti (phe) division akhnoor. 3. annual rate contract for repair of submersible pumps installed at various tube wells/dug wells in jal shakti (phe) division akhnoor. 4. repairing of submersible pump (v-6).
Tender For tggenco-ytps-up keeping of toilets, urinals and maintenance of sewage pipe lines and manholes at various locations in water system (ptp) area including chemical lab buildings stage-i and ii, fuel oil unloading and forwardingpump house buildings of yadadri thermal power station at veerlapalem(v), dameracherla(m), nalgonda district from 01.04.2026 or actial date of commencement to 31.03.2027.