Web Analytics Made Easy - StatCounter

Freezing Box Tenders

Get complete information related to latest Freezing Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Freezing Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Freezing Box Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43306328 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.

Central Government And Public Sector

CTN :43156629 Due date: 27 Dec, 202527 Dec, 2025 NA
Tender For supply of , arm head rod axle for drum filter as per drg.no:nalco/mech/misc/2686item no:1, df-22/23/24 agitator's arm pin assembly as per drg. no. nalco/mech/misc/tb/1043 r3, item nos. 1 to 5 in assembled condition.05 nos. out of 10 nos. of pins shall have m40 thread length of 35 mm.instead of 45 mm., step length of 83 mm. instead of 93 mm. and totallength of 163 mm. instead of 173 mm. for these 05 nos. of pins, theaforesaid dimensions shall supercede the drawing dimensions. #, drum filters-22/23/24 arm pin's bush as per drg. no. nalco/mech/misc/tb/1043 r3, item no. 6, moc: brass, drum filters 22/23/24 agitator arm in completely assembled condition asper drg. no. nalco/mech/misc/267 r1, fixing plate for a.h rod axle asper drg. no:nalco/mech/misc-2686, itemno-2, df-22/23/24 agitator's crank head rod axle (bottom side) as per drg.no. nalco/mech/3156. the surface finish has to be proper for fitmentof bearing as shown in the drawing., drum filter-713 arm pin's bush as per drg. no. nalco/ mech/3450, moc brass#, crank link (item no.3) for agitator of drum filter: 22/23/24 as per drg.no.nalco/mech/misc/4700, emergency cooling water nozzles complete assembly bottom 6 mm. as perdrg, no. nalco/mech/misc/2456 r1, emergency cooling water nozzles complete assembly middle 8 mm. as perdrg. no. nalco/mech/misc/2457 r1, emergency cooling water nozzles complete assembly top 9 mm. as per drg.no. nalco/mech/misc/2458 r1, air ring of esp screw conveyor 63 and 64 a/b, item no. 5 of table foritem no. 2, drg. no. nalco/mech/misc/ta/4211 r1, gland housing of esp screw conveyor 63<(>8 64a / b as per drg. no.nalco/mech/misc/379 r3, grease ring of esp screw conveyor 63 and 64 a/b, item no. 5 of table foritem no. 1, drg. no. nalco/mech/misc/ta/4211 r1, drive shaft as per drg. no. drg. no. nalco/mech/misc/4700, item no.2

CTN :43205945 Due date: 06 Jan, 202606 Jan, 2026 NA
Tender For tender for supply of make- ird mechanalysis limited , ird544m - vibration sensor , inductive velocity , top exit , mil 2-pin connector , 42.52mv/mm/s , 10 hz - 1 khz sku - m97120 , make- ird mechanalysis limited , stud for vibration sensor item no 1 , mounting/grub screws , 1/4 inch-28unf male , m6 x 1 male sku - stud-m6 provides connection between vibration sensor and mounting pad , m/s ird mechanalysis limited , vibration sensor mounting pad mild steel blackodized for ird544m (60x60x16 mm) with m6 thread for item no 1 tapped sku - ms-pad-ird544m , make- m/s ird mechanalysis limited , vibration sensor cable assembly for item no 1 , signal cable teflon 3.5mm dia , ss conduit 5mm id , 15 meter length straight , 2 pin ms , shielded , spade lugs at free end sku - m601015spade lugs at free end carry following colour code- red core- signal live , black core- signal ground , green core- signal shield , make- ird mechanalysis limited , eddy current pickup set comprising of probe , driver and connecting cable for 9 meter system. constituents. , make- m/s ird mechanalysis limited ird8800 rack , 8 position , 5u sku - m88008 this is the bin and will accomodate ird8800 cards , make- ird mechanalysis limited ird8800 (8800) , m88250 (88250) casing vibration module , 2ch velometer input (mv /mm/sec) and 1ch key phasor input , api standard 670 compliant sku - m88250-dc ird8800 series module m88250 can work with all types of velocity output vibration sensors that provide mv/mm/sec output - like ird531 (4 mv/mm/sec) and ird544m (42.52 mv/mm /sec) , make- m/s ird mechanalysis limited , ird8800 (8800) , m88900 (88900) - speed module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88900-dc , input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcp-ip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , ird8800 (8800) , m88600 (88600) - eccentricity module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88600-dc input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcpip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , 35 mm din rail mount industrial grade power supply , 480 w , product- rps480 , 24 v dc output , dimension- 60 x 154 x 158.55 mm (w x h x d) , weight- 1050 gms , sku - rps480-24-ce supports 90 - 264 vac / 127 - 370 vdc power factor more than 0.95 full load over entire input range protection against short circuit , overload , overvoltage & over temperature cooling by free air convection ul 508 approved (e522848) efficiencies up to 93 % dc ok relay contact , make- ird mechanalysis limited , cabinet 1500 x 600 x 600 in mm , ip32 sku - cabinet-1500-600-600-ip32 , installation commissioning and calibration check of all supply sensor with unit at site

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
 Loading, Please wait...

Connect us via What's Up