Web Analytics Made Easy - StatCounter

Frequency Counter Tenders

Get complete information related to latest Frequency Counter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Frequency Counter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Frequency Counter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43948959 Due date: 23 Feb, 202623 Feb, 2026 NA
Location: Goa - Goa Goa - Goa
Tender For corrigendum : supply of pan class="text-red-selected">frequencypan> pan class="text-red-selected">counterpan> (q3)

Central Government And Public Sector

CTN :44085506 Due date: 11 Mar, 202611 Mar, 2026 NA
Tender For supply of pan class="text-red-selected">frequencypan> pan class="text-red-selected">counterpan> (q3)

Central Government/Public Sector

CTN :43961717 Due date: 04 Mar, 202604 Mar, 2026 NA
Tender For supply of 3 ghz two channel rf pan class="text-red-selected">frequencypan> pan class="text-red-selected">counterpan>

CTN :43941204 Due date: 02 Mar, 202602 Mar, 2026 NA
Tender For supply of electrical and electronics laboratory setup - rlc resonance trainer kit series and parallel resonance, kit consists of voltmeter and pan class="text-red-selected">frequencypan> pan class="text-red-selected">counterpan>, inbuilt signal generator, experiments can be performed with or without oscilloscope inbuilt power supply, maximum power transfer theorem trainer kit maximum power transferred from a source to a load when the load resistance is made equal to the internal resistance of a source. inbuilt fixed dc regulated power supplies : 12vdc, meters, ammeter &amp; voltmeter, required components provided, circuit diagram printed on front panel &amp; all important test points are brought out on front panel power requirement : 230 vac, clamp on meter suitable for min 300 a ac/dc current measurement range: 0.2 to 300 a, accuracy 1.5% ac voltage: mv to 1000 vac, accuracy: 0.75% dc voltage: 30mv to 1000 vdc, accuracy: 0.5% resistance: upto 30 mohm, accuracy: 0.5% capacitance 1 nf to 30 micro f, accuracy: 1% pan class="text-red-selected">frequencypan> upto 100 khz, accuracy: 0.5% auto hold, max/min, auto/manual, diode, ip20 protection., digital meter: portable table top type, with cabinet and stand, terminals brought out for connections, range: voltmeter:0-750v ac 0-500 vdc, ammeter:0-20a ac 0-20a dc 2 nos each range, electronic energy meter( single phase) 240vac, 20aac, electronic energymeter( three phase) 400 vac, 30 aac, digital multimeter ¾ digit , true rms ac voltage range : 1 mv to 1000v, accuracy < 1% dc voltage range : 10 mv - 1000 v, accuracy < 0.5% ac current range : 1 ma-10a, accuracy < 2%, dc current range 0.01 ma-10a, accuracy < 1.5%, resistance: 100 mohm-60 mohms, accuracy < 0.5% input impedance: 10mohm capacitance: 1 nf – 60 mf, accuracy: < 5%, pan class="text-red-selected">frequencypan>: 0.01 hz – 10 khz, accuracy < 0.1% duty cycle, temperature and diode test, lcd display with auto / manual range , included accessories: test leads, rubber holster, temperature probe, battery charger 12 / 24v dc, 15 a, digital power factor meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: single phase, 220v ac, 5a, digital pan class="text-red-selected">frequencypan> meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 45-55 hz, digital wattmeter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 220v, 5a ac single phase (2 nos) 400 v, 5a ac, three phase (2 nos), single phase half wave, full wave , fully controlled bridge rectifier / converter design to study to controlled rectifier &amp; observe wave form on cro. meters provided of suitable range, in built power supply. load resistance, controls for phase angle. circuit diagram printed, &amp; test points brought out on front panel. power requirement: 230 vac +10%, 50hz. supplied with patch chords &amp; instruction manual, ups trainer kit input range: 170 to 270 v, ac output (input present): 195 to 250 v capacity: 200 w battery: 12 v / 7 ah, maintenance free, test points for experimentation purpose. panels: input / output / battery / transformer / avr / charger /inverter study of charger study of changeover logic study and working of ups, smps trainer kit input : 110- 230v, output : 12v dc, switching transformer, scr commuation trainer kit two dc regulated power supplies 0-30vdc/150ma &amp; 0-1 vdc/150ma, three meters for voltage &amp; current measurement , scr 2p4m mounted behind the panel, connections of supplies, meters &amp; scr brought out at 4mm sockets., characteristics trainer kit for scr,diac,triac, ujt,igbt instrument comprises of three dc regulated power supplies 0-15 vdc/150ma, 0-50 vdc/150ma &amp; 0-2.5 vdc/150ma, four round dual range meters for voltage &amp; current measurement,ujt, scr, diac, triac &amp; their supportive components mounted behind the panel, connections of supplies, meters &amp; components brought out at 4mm sockets., kit for speed control of dc motor using microcontroller eters (digital) :0-200v dc, 0-500ma dc instrument provided with 1/12 hp dc motor, on board phase a

CTN :43663128 Due date: 02 Apr, 202602 Apr, 2026 NA
Tender For procurement of spares for mi-17v5 helicopter - cable equipment, collective patch tester, compressor rotor 1st stage blade wear control device, antenna matching unit, vibration balancing analyser equipment with main and tail rotor kit, hoist, combination test, attenuator, pan class="text-red-selected">frequencypan> pan class="text-red-selected">counterpan>(upto 500 mhz), indicator, modulation depth and pan class="text-red-selected">frequencypan> deviation meter, spectrum analyzer, test programming set for cma-2012, device, lamp, test panel for testing fire protection system ssp-fk
 Loading, Please wait...

Connect us via What's Up