Get complete information related to latest Frp Structure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Frp Structure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Frp Structure Tenders.
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frpstructure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For supply of chlorine handling spares - lifting beam with adjustable hooks, moc ms ,chlorine tonner key ,frp half hood for | chlorine tonner ,chlorine valve /isolation valve (iso /3224) ,tonner roller supports in sets, 1 set 2 nos =
Tender For corrigendum : tggenco - ktps vii stage - p31 - chemical div- procurement of frp chlorine safety tonner hood and surface leak arresting kit for 1-ton capacity chlorine tonner - quotation called for - reg.
Tender For supply of l shape wall table module , half pyramid shape electrical box , pp sink with three way tap , two way eye wash , wall table module 9100 x 900 x 900mm ht , raceway with 24 nos of 16 by 6amp switch , spot extractor , 3 hp motor and blower , 32 mtr pvc duct 6 nos of bend and 6 nos , anti vibration table , fume hood 1500 x 900 x 2430 , 2 hp motor and blower , 5 mtr frp duct , center table module , raceway with 10 nos of 16 by 6amp switch , gas pipeline system for inst lab and , installation charges for instrument
Tender For supply of wall bench -wb - 1- size l 4540 mm x w 800 mm x h 750 mm , wall mounted storage cabinet size l 900 mm x w 380 mm x h 760 mm , wall bench -wb - 2- size l 2360 mm x w 750 mm x h 900 mm , wall mounted storage cabinet size l 750 mm x w 380 mm x h 760 mm , corner bench -cb - 1- size l 1030 mm x w 1030 mm x h 900 mm , wall bench - wb - 3- size l 3100 mm x w 750 mm x h 900 mm , wall mounted storage cabinet size l 600 mm x w 380 mm x h 760 mm , chemical storage cabinet -csc- size l 900 x d 485 x h 1830 mm , const. bypass type bench fume hood size l 1200 x d 915 x h 2300 mm for non - ac labs , exhaust fan -400 mm dia-one fan for 1 nos. chemical storage cabinet , wall bench -wb - 4- size l 3260 mm x w 750 mm x h 900 mm , anti vibration table -avt- size l 750 x w 750 x h 900 mm , exhaust ducting in pp plus frp - round shape- construction -3mm plus 2mm
Tender For corrigendum : supply of laboratory furniture d d - wall bench wb - 1- size l 4035 mm x w 750 mm x h 900 mm , wall bench wb - 2-size l 3055 mm x w 750 mm x h 900 mm , island bench ib - 1- size l 3500 mm x w 1500 mm x h 900 mm , island bench ib - 2- size l 2350 mm x w 1500 mm x h 900 mm , wall bench wb - 3-size l 1240 mm x w 750 mm x h 900 mm , wall bench wb - 4- size l 1885 mm x w 600 mm x h 750 mm , corner bench cb - 1-size l 880 mm x w 880 mm x h 750 mm , wall bench wb - 5-size l 2679 mm x w 600 mm x h 750 mm , wall mounted storage cabinet size l 900 mm x w 350 mm x h 600 mm , lab stool , lab chair , glassware storage cabinet -gsc- size l 1000 x d 450 x h 1830mm , storage cabinet size l 900 x d 600 x h 750mm , low constant volume type bench fume hood -size l 1500 x d 915 x h 2300 mm , exhaust fan -315 mm dia - one fan for 1 nos. 1500 mm wide fume hood , wall bench wb - 1- size l 2575 mm x w 900 mm x h 900 mm , wall bench -wb - 2- size l 4800 mm x w 900 mm x h 900 mm , wall bench -wb - 3- size l 3025 mm x w 750 mm x h 900 mm , island bench -ib - 1- size l 3850 mm x w 1500 mm x h 900 mm , wall bench wb - 4- size l 2750 mm x w 750 mm x h 750 mm , wall mounted storage cabinet size l 900 mm x w 350 mm x h 850 mm , glassware storage cabinet-gsc- size l 1000 x d 450 x h 1830mm , exhaust ducting in pp frp ) /bid number : gem/2026/b/7489965 * /dated: 30-04-2026 & & / bid document 1 / 27