Get complete information related to latest Fuel Pump Station Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuel Pump Station Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuel Pump Station Tenders.
Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 5-11 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved en iso 20345 :2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistantoutsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance (esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design tominimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 6-11 as per attached chart) [ warranty period: 12 months after the date of delivery ]
Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 6-9 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved ? en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance(esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 6-10). (size and quantity details furnished in annexure). [ warranty period: 30 months after the date of delivery ]
Tender For rate contract for supply of materials and execution of various maintenance works, as and when required during emergency in electric division anantnag kpdcl for the fy year 2026-27 - supply, erection, testing & commissioning of s.t pole 11mtr. long sp-56 with base plate & cap for ht. strictly as per rec standards, erection, testing & commissioning of s.t pole 11mtr. long sp-56 including its carriage from divisisonal store to site, supply, erection, testing & commissioning of s.t pole 9mtr long sp-33 with base plate & cap for ht. strictly as per rec standards, erection, testing & commissioning of s.t pole 9mtr long sp-33 including its carriage from divisisonal store to site, supply, erection, testing & commissioning of s.t pole 8mtr long sp-15 with base plate & cap for lt. strictly as per rec standards, erection, testing & commissioning of s.t pole 8mtr long sp-15 including its carriage from divisisonal store to site, providing of hydraulic crane on hire basis for loading/unloading of dts of different capacities inclouding fuel and operator faling in the juridection of ed anantnag, erection, testing & commissioning of pcc pole 8mtr long including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 100mmsq (dog) conductor, laying, stringing, tensioning & binding of acsr 100mmsq (dog) conductor including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 50mmsq (rabbit) conductor, laying, stringing, tensioning & binding of acsr 50mmsq (rabbit) conductor including its carriage from divisisonal store to site, supply, laying, stringing, tensioning & binding of acsr 30mmsq (weasal) conductor, laying, stringing, tensioning & binding of acsr 30mmsq (weasal) conductor including its carriage from divisisonal store to site, providing & fixing of ismc 100x50x6mm channel iron cross arms for x-mer frame 9long @ 25.2 kg each -1 no including nuts & bolts, fixing of ismc 100x50x6mm channel iron cross arms for x-mer frame 9long @ 18.63 kg each -1 no including nuts & bolts, providing & fixing of ismc 75x40x6mm channel iron cross arms for x-mer frame- 1 nos @18.63 kg each 9 long including nuts & bolts, fixing of ismc 75x40x6mm channel iron cross arms for x-mer frame-, providing ,fixing, of ismc 75x40x6mm x-arm 5 long, fixing, of ismc 75x40x6mm x-arm 5 long-, providing ,fixing, of ms angle iron braces 50x50x6mm-4.5 ft long,, fixing, of ms angle iron braces 50x50x6mm-4.5 ft long, providing and fixing of sprial earthing made of 115 turns of gi wire swg no.8 placed 1.5m below ground level including excavation of pit, refilling the same withsoft soil, fixing of sprial earthing made of 115 turns of gi wire swg no.8 placed 1.5m below ground level including excavation of pit, refilling the same withsoft soil, supply,fixing, testing & commissioning of 11kv link set (polymer) station type as per is standards, fixing, testing & commissioning of 11kv link set station type (polymer/porcelain )as per is standards, supply,fixing, testing & commissioning of 11kv link set heavy duty as per is standards, fixing, testing & commissioning of 11kv link set heavy duty (polymer/porcelain ) as per is standards, supply,fixing, testing & commissioning of 11kv do fuse set (polymer )as per is standards, fixing, testing & commissioning of 11kv do fuse set (polymer/porcelain ) as per is standards, supply,fixing, testing & commissioning of 11kv la set (polymer )as per is standards, fixing, testing & commissioning of 11kv la set (polymer/porcelain ) as per is standards, providing and fixing of lt fuse set as approved by kpdcl., supply,fixing, testing & commissioning of 11kv disc set (polymer) 45 kn complete set, supply,fixing, testing & commissioning of 11kv disc set (porcelain) 45 kn complete set, fixing, testing & commissioning of 11kv disc set (polymer/po
Tender For carrying out detailed route survey for mrpl petroleum pipeline project from marketing terminal devangonthi to existing common user fuel farm station at kempegowda international airport
Tender For construction of road and drain from sh 65 gupta-fuel to rupauli police station chowk via rupauli village ward no. 01 under nagar panchayat rupauli (purnia) area, as well as drain construction work from rupauli police station chowk via block office gate to rupauli canal along sh_65
Tender For tender cum reverse auction for operation and maintenance services of mafffls aviation fuelstation at chhatrapati shivaji maharaj international airport mumbai
Tender For corrigendum : setting up of fuelpump ms/hsd + cng + electric charging station and cafeteria/restaurent in the land of area 27 are 62.7 sq.m, owned by traco cable company limited , irimpanam, tripunithura, ernakulam.