Get complete information related to latest Fuel Strainer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuel Strainer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuel Strainer Tenders.
Tender For supply of plant spare : : -oil filter jcb 3dx , txn oil filter , air filter inner , air filter outer , stopper cable , rear drive shaft cross , bucket sim , tail light lamp set , boom bush , front axle bearing , rear axle bearing , bearing jcb 3dx , water separator filter , bucket teeth pin , feed pump , fan belt , rear hub seal , pump seal hyd kits , jcb 3dx steering tie rod assy both site , self starter , jcb 3dx alternator , fuel filter cotton type , fuel filter paper type , air filter w type , engine oil filter , on off cock , fuel tank cap , hyd filter assy , seal oil ring , arm cyl seal kit , hyd stainer , air filter element inner , solenoid , thermostat , working lamp assy , return line hose , flexible hose , fuel filter , oil filter , air cleaner , bearing , fuelstrainer , hyd filter
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of complete overhauling, oil leakage attending, high vacuum oil filtration and testing of 25 mva, 220/7 kv, 3 nos of power transformer at gtps,..
Tender For oil filtration/maintenance of 300kva,6.6kv/440v sl.no.1937 at coke plant substn. lbc(ii)rep. of 250kva 11kv/440v crompton parkinson make transformer sl.no.18144 installed at npts(iii)and cork sheet and stud changing oil filtration and overhauling of
Tender For for partial repairing and filtration of transformer oil of various transformer like 150kva6.6kv/440v,200kva 6.6kv/440v,100kva 550v/440v and 150kva 550/440v installed ekra substation, colony and office under basdeopur colliery of sijua area
Tender For replacement of old r phase bushing, overhauling of ol tc alongwith oil filtration for 40mva 132/33kv power transformer no. ii at gss, khurda
Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20