Get complete information related to latest Fuel Tank Cap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuel Tank Cap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuel Tank Cap Tenders.
Tender For corrigendum : 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fueltankcapacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fueltankcapacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For regular operation and maintenance of street lights and high mast light with material for two years at different industrial areas of ajmer zone, amounting to rs. 16.46 lakh - street light repairing work and on/off main switch in industrial areas of ajmer including rewiring of fixtures, changes of ballast, clamp, stater, condenser, tube rods, stater sheet, tube holder, mercury & sodium vapour lamps, ignitor & refixing on poles and change of fixtures, change of main switch, kit kat fuse wherever necessary complete including joining of jumpers, complete repairing of tube light fixtures, mercury vapour and sodium vapour lamp fixture ( all required material will be arranged by the contractor except new fixture). led fixtures., contract for operation and maintenance of high mast light (led fixtures) with material as per enclosed terms and conditions. the scope of work includes operation and maintenance of high mast lights, on and off high mast light, electrical panel, repairs of light with all required materials, replacement of necessary electrical components, cable, timer, contractor etc including excavation for cable and maintaining the light in good condition as per enclosed terms and conditions.
Tender For supply of safe carriage of 36kv vcb , dismantling of defective 36kv vcb of 33kv spc feeder , erection of new 36kv vcb , making of jumpers for 36kv vcb by acsr p.c. , cable termination and earthing of new 36kv vcb