Get complete information related to latest Fuse Box Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Box Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Box Repair Tenders.
Tender For supply of motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switchboard cabinet of lhb type ac coaches. accepted make & cat. /model no.: rdso-approved make and model as per common bom serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021, make :-abb,legrand,schneider,l&t,siemens and eaton. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs] ]
Tender For supply of 15 amp, dp miniature circuit breaker (mcb), c curve, operating voltage 230/415v, breaking capacity 10ka as per is/iec 60898-1 or latest if. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of residual current circuit breaker with over current protection(rcbo) 16 amp , voltage rating : 415 v ac, 50 hz , 4 pole , current rating : 16 amp , breaking capacity : 10 ka , tripping characteristic :d- curve , residual current parameters : i) 30 ma residual current ii) impulse current withstand at 8/20 micro second pulses = 3 ka , mounting : din rail similar to the cat no- aug3d401603 of l&t as per rdso letter no : el/7.1.108/sbc/355/non ac coaches dt 14.10.2025 , make-lk, abb, legrand, siemens, schneider or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of residual current circuit breaker with over current protection(rcbo) 16 amp , voltage rating : 415 v ac, 50 hz , 4 pole , current rating : 16 amp , breaking capacity : 10 ka , tripping characteristic :d- curve , residual current parameters : i) 30 ma residual current ii) impulse current withstand at 8/20 micro second pulses = 3 ka , mounting : din rail similar to the cat no- aug3d401603 of l&t as per rdso letter no : el/7.1.108/sbc/355/non ac coaches dt 14.10.2025 , make-lk, abb, legrand, siemens, schneider or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of motor protection circuit breaker (mpcb) for compressor unit 1.1,1.2,2.1 & 2.2 heater 1& 2 current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3 pole, voltage rating 415 v ac, conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1). accepted make as per bom of rdso/pe/spec/ac/0184/2015 rev. (1), revised vide rdso letter no. el/7.1.108/mssbc dated 17.09.2021 (sn 39) abb catalogue noms116-10, legrand, schneider catalogue no. gv2me14, l&t catalogue no. st418980000, siemens catalogue no. 3rv2011-1ja10, eaton catalogue no. pkzm01-10. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins
Tender For providing services overhauling and testing of on-load tap changer (oltc) make ctr and high voltage circuit breaker on-site at hbl plant sugauli
Tender For works contract for 1)imp est for control and relay medium voltage ac panel id 110kv ss and controlcable 8x2.5sqmm for replacement 110/11kv ss kuzhithurai section. 2)imp est for replacement of 30v to 110v dc distribution panel dc system in 110/11kv ss kuzhithurai section. 3)imp est for control cable & relay panel for lv breaker, tripping coil and closing coil for replacement of 30v to 110v dc system under 110/11kv ss under kuzhithurai section.