Web Analytics Made Easy - StatCounter

Fuse Repair Tenders

Get complete information related to latest Fuse Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45732492 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of cooling tower spares & service cooling tower no. 1, spares parts of cooling tower ,ac b eliminator 71 ,ac b eliminator 58 ,r.c.c. spacer ,s.s. wire grid 44 y76 (14 swg )(4 x 12 ) 1hw01194 ,pvc v bar 8 8 , code mpf01047 ,cable tie 6 ,target nozzle ,s.s. wire 14 swg ,work details;- *dismantling & re- fitting of s.s. wire grid & pvc v bar properly in all respect. *dismantling & re-fitting after cleaning of acb drift eliminator along with ,rcc spacer complete in all respect. *binding of s.s. wire grid with rcc beam should be properly done. *fitting of target nozzles at position should be done. *cell ,repairing all work should be done completely to insure the trouble free working of cooling tower during the season. *minor repairing jobs for other cells also to be done. ,spares for paharpur cooling tower model 1400-02-(16 at) ,spare coupling with distance shaft pipe (for gear box to motor connection)flange, flow control (f.c) valve size 12 dia.

CTN :45478137 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : items - computer and servises and otheres, mcb (miniature circuit breaker), acb (3200a/4000a ), acb (air circuit breaker), allen key set, amf relay, ammeter, annunciation system, anti-corrosion spray, arc flash suit, arc flash suit (ht/lt panel ), auxiliary contacts, avr (automatic voltage regulator), battery charger, blower/air blower, breather assembly, bus coupler acb, busbar insulators, busbar supports, cable glands, cable glands, cable lugs, cable ties, cable ties, changeover switch, clamp meter, clamp meter, combination pliers, consumables, contact cleaner spray, contactor, continuity tester, control cable, control fuses, control relay, control wires, cooling fan, copper busbar, crimping tool, ct (current transformer), current transformer (ct), dg set synchronization panel (3 750 kva), digital multimeter, digital multimeter, discharge rod, earth fault relay, earth switch, earth tester, earthing rod, electrical contact cleaner, electrical gloves (11 kv rating), electrical safety gloves, emergency stop switch, energy meter, engine control module, face shield, ferrules, ferrules, flexible wire, frequency meter, fuse fuse base, heat shrink sleeves, heat shrink tubes, hrc fuse, hrc fuses, ht protection relay, indicator lamps (r/y/b), infrared thermometer / thermal camera, insulated screwdriver, insulation tape, isolator switch, lightning arrester, load sharing module, lockout-tagout (loto) kit, loto kit, lt pcc/mdb panel, lubricant spray ( ), lugs, maintenance tools, mccb, mccb (molded case circuit breaker), megger (insulation tester), megger 5 kv, microfiber cloth, motorized mechanism, multifunction meter, multifunction meter, nose pliers, numerical protection relay, oti (oil temperature indicator), over current relay, overload relay (olr), phase sequence meter, phase sequence tester, plc module, power analyzer, power cable, power factor meter, protection & metering, pt/vt (potential transformer), push buttons (start/stop), pvc insulation tape, reverse power relay, rust remover, safety equipment, safety goggles, safety helmet, safety helmet, safety shoes, safety shoes, screwdriver set, secondary injection test kit, selector switch, shunt trip coil, side cutter, silica gel, smps (power supply), soft brush, spanner set, speed governor module, spiral wrapping, spring charging motor, starting relay, synchronizing relay, terminal blocks, thermal camera, thermostat, timer relay, torque wrench, transformer buchholz relay, transformer oil, under/over frequency relay, under/over voltage relay, uv coil, vacuum cleaner, vcb (vacuum circuit breaker), voltage tester, voltmeter, wire markers, wire stripper, wti (winding temperature indicator), , , , comprehensive maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor & majour spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete., annual maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete.

CTN :45688266 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For sf6 breaker, vcb, acb servicing, testing and spares

State Government

CTN :45686226 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of lauritz knudsen (formerly l & t) make switchgear spares for chp elect- fuel section at gsecl ukai tps. (chp maintenance (electrical)-et-6304) - l&t make 3 pole power contactor, type- ml-2, ac-3, 32 a, 415 v ac, l&t make,3pole power contactor in open execution type ml-4 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 70a cat.no.ss 90910, l&t make 415v switch gear (acb), l&t make,3pole power contactor ml-6,coil voltage 110vac, ac-3 rating 110a cat.no. ss90921, l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, l&t make 3 phase power contactor type mnx 25 ac-3 rating 25a,cat.no.cs94110, l&t make 3 phase power contactor type mnx32 ac-3 rating 32a,coil voltage 110v ac,cat.no.cs94111aooo, power contactor mnx 40 coil:110vac cat no.:-cs94190 make:-l&t, l&t make 3 phase power contactor type mnx110 ac-3 rating 110a,coil voltage 240v ac,cat.no.cs94137, l&t make power cantactor type- mnx 300 with 2 no + 2 nc aux. contact, coil voltage 110 volt ac, ac-3 rating 300 amp., cat. no. cs 90280., l&t make,3pole power contactor in open execution type mn-400 for ac.ckt. with 2 not 2nc aux- contact,coil voltage 110vac, ac-3 rating 400 * cat.no.ss 94043, l&t make 415v switch gear (acb), contactor kit ml-2 ss 95307, l&t make contact kits with out coil for contactor type:- ml 4, cat.no - ss 91257, spares kit without coil for contactor ml6, cat. no. ss 95313, make - l & t, l&t make spare kit without coil for ml-10 cat no ss 95315, l&t make 415v switch gear (acb), l&t make spare kit without coil for ml-12,cat no.ss 91127,l&t make 415v switch gear (acb), spare contact kit for l&t make mnx 110 power contactor cat no cs94154, spare contact kit for l&t make mnx 400 power contactor cat no cs94161, coil for l&t make power contactor. ml-8/10/12 ss91011, 220vac,/110vac, l&t make spare coil for mnx 400, coil voltage 110 vac, cat no cs94195, l&t make fornt mounting add-on block 2no + 2nc cat. no.cs94114 for mnx 9a to 40a contactor, l&t make, mnx type front mounting add on aux. contact block 1 no + 1 nc, cat no cs94118, l&t make, mnx type front mounting add on aux. contact block 3 no + 1 nc, cat no cs94113, l&t make control , contractor type mm01 with 4 ho +4hc contact , coil voiltage 110 vac cat no. ss 92014, l&t make 415v switch gear (acb), l&t make control contactor, type mm01 ac with 5 no +3nc contact , coil voiltage 110 vac, cat no. ss 92014, l&t make 415v switch gear (acb), l&t make dc control mx mini mx 09 1nc cat no cs94024, l&t make bi metal o/l relay for ml -2 range 9.0-14a , cat no ss 9185900ao, l&t make 415v switch gear (acb), l&t bimetal thermal overload relay with single phasing protection.mn-2 9.0-15.0a ss94142, l&t make ml type,thermal overload relay, range 20-32amp,direct mounting on ml 2/3 contactors,cat no-ss91859ooeo, bimetallic relay with single phasing protection, range: 66-110a, make: l&t, cat. no.-cs9422700k0, l&t make bimetal thermal over load relay with single phasing protection, mn 12 type, cat.no. - ss94138oomo, relay range 3 - 5 amp operation, ct operated in combution with 90 - 150 amp (ct operated) seprate mounting., l&t make b/m o/l relay,mn-12 l type,range-180-300a,cat no-ss 94127 ooqo, l&t make bimetal (th) over load relays ( with single phasing protection) thermal o / l relaytypemn 2cat.no.ss 9412700 porelay range3 - 5 ampoperationct operatedin combution with 90 - 150 amp ct mounted on ct, switch disconnector fuse unit tpn 32a 415v make:-l&t type:-fn, l&t make switch disconnector (415 volt, 50 hz) fuse units type: fn 63 tpn, cat.no.: sk 95421, capacity:- 63 amp, ac, 23 amp, no of poles: 3 + n link, l&t make switch disconnector-fuse, type-fn 125, 125amp, tpn+fuse links, cat no- sk 95001., l and t make switch disconnector isolator, type fn 250 tpn, cat. no. sk95683., landt make switch disconnector-fuse, type-fn400, 400amp, tpn, cat no

State Government

CTN :45093995 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of c&s electric make acb & panel spares for 415v mcc at emd ii, gsecl utps. (emd-5 et-6262)

State Government

CTN :45669393 Due date: 15 Jul, 202615 Jul, 2026 14.30 Lacs
Tender For procurement of essential spares for 105 mw ushp ii kangan hep - transformer protection relay ge micom, p643926a6m0060м, transformer protection relay ge micom, p442916b6m0710m, mccb dn2 250d, 3-pole, 200 amps l&t, d-sine, single phase preventive relay, vsp-2, minilec, contactor, 3tf56, siemens, contactor, 3th30, siemens, acb 1000 amp, edo, 3-pole, l&t, fuse, 400 amp, 415v, l&t, relay trip w/overload relay, 160-250 amp, 3ua66 00-3c 3ux1423, siemens, vacuum interrupter, 11kv, 1250 amp (3pc set), 11kv polymeric composite disc insulator 12kv, min failing load 45kn, lighting impulse 75kv positive and 80kv negative, creepage distance 320mm, 11kv polymeric composite pin insulator 12kv, 5kn, lighting impulse 75kv positive and 80kv negative, creepage distance 320mm, led lamp, 12 watt, cutting electrode, h 901, 4mm x 450mm, cast iron electrode, 4mm x 450mm, cotton knitted safety protection grip work gloves (10 pair pack)

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government And Public Sector

CTN :45600007 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of spares for cooling tower along with dismantling and refitting works on door delivery basis at hbl plant sugauli, east champaran and lauriya, west champaran, bihar - supply of sapres for distillation cooling tower spares along with repair maintenance are mentioned below:, louver coulmn assy 17 , coulmn 3 x3 x18 , center guard 2 x6 x9 , besion side 2 x8 x8 , hader fatta 2 x12 x8 , wooden guard 2 x6 x12 , batten 2 x2 x8 , coulmn 3 x3 x10 , half round, chapas, airseel ply, center guard 3 x6 x8 , acb louver, casing sheet 6 , wooden guard 2 x4 x9 , wooden guard 2 x4 x8 , wooden guard 2 x6 x8 , pvc nozzle, ss grid 74 x44 , ss 304 grid 36 x44 , hanger ply, fan dack plank 2 x6 x8 , wooden guard 2 x4 x12 , mastic compound, ss nails, coch bolt, mshdg nut & bolt x7 , mshdg nut & bolt x6 , mshdg nut & bolt x5 , mshdg nut & bolt x4 , mshdg nut & bolt x9 , sksntilng assy 18 , rubber bush for gear box coupling, rubber bush for cooling tower pump, service charge, fermentation cooling tower spares along with repair maintenance are mentioned below:, pvc eliminator, wooden guard 2 x6 x12 , ss grid 74 x44 , wooden guard 2 x4 x12 , service charge, mee cooling tower spares along with repair maintenance are mentioned below:, pvc eliminator, half round, casing sheet 7 , cashing sheet 5 , wooden guard 2 x4 x8 , wooden guard 2 x6 x8 , ss grid 74 x44 , hanger ply, fan dack plank 2 x6 x8 , wooden guard 2 x4 x12 , ss nails, coch bolt, service charge

corporations/Associations/Others

CTN :45601900 Due date: 02 Jul, 202602 Jul, 2026 10.90 Lacs
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k

CTN :45525967 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For discount on spare of siemens l and t make - all type of contactors make- siemens, contactor accessories, switch disconnectors fuse units, sds, on-load change over switches and hrc fuse , mccb s 3vt, mccb s 3vl, bimetal overload relays, motor protection circuit breakers, motor starters, all type of spare kit & coil, mcb, indicator, push button, air circuit breaker (acb), air circuit breaker accessories., push button element teknic, power contactors & control contactors, thermal o/l relay mnx type 9-40 make- l & t, power contactors & control contactors, thermal o/l relay mnx type 45 & above , starters, ml contactors and ml relays, mmoo, mmo1 make- l & t, spares of items 1 (a), (b) & (c), switches fn interior, fn switches in ss enclosers & fuses, spares of items 2 (a), spares of items 2 (b), mccbs dh series dh100 & dh125, mccb s dm series, dl series, mccb s du, dth, etc, spares of item air circuit breakers manually fixed type, acb s mdo & edo type, air circuit breaker manually fixed type, mdo & edo type.
 Loading, Please wait...

Connect us via What's Up