Get complete information related to latest Fuse Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fuse Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fuse Sale Tenders.
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For annual tender 2026-27 supply of electrical goods in perungulam town panchayat - 4 feet flourescent tube light, 40w copper choke, 40w tube light starter, 36w / 40w tubelight electronic choke, tube light side lock holder, insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, led fitting top protection glass - street light, led fitting top protection glass - flood light, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 24w t5 power saver lamp, 2x24w t5 power saver choke, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 80w led power saver street light fitting, 120w led power saver street light fitting, 150w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 10hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., service charges automatic on/off street light
Tender For supply of shunt trip assembly with coil 110v dc , 16 plug and socket , jaw contact 630a complete , front operated manual type charge mechanism , vacuum interrupter , mushroom head push button , tnr switch spring return type , rectifier capacitor unite 1 ph 16 amps 110 v ac to 110v dc , tpnd 20c 1ef idmt high set oc setting 50-200 ef 5-80 and high set oc setting 200-2900 , indicating lamp assembly , push button with element for start stop reset etc. , earth leakage relay 50ma to 2a 12v ac , stud type terminal , 3.3kv, 3 amps p.t fuse , surge arrestor 3.3 kv 5 ka , brass gland with core and ci clamp ht glass type , 6.6kv grade support insulator , hrc fuse link 10 a , hrc fuse link 2a , neutral link , 20 amp fuse base carrier , power factor meter 3.3kv 110v , under voltage relay 110v ac setting range 50- 90 , breaker micro switch t type , front window glass , no volt relay with on delay timer range 0-15min , limit switch , 3.3kv epoxy resin cast drive insulator , 3.3kv 1amp pt fuse , over voltage relay , ground check relay , pilot relay 110v dc , master tripping relay , sensitive elr , overcurrent relay * /bid number : gem/2026/b/7619251 + /dated: 17-06-2026 ' ' / bid document 1 / 54
Tender For supply of electrical materials on annual rate contract. - 1.5 sq.mm f.r copper pvc insulated wire., 2.5 sq.mm f.r copper pvc insulated wire., 4 sq.mm fr copper pvc insulated wire., 6 sq.mm fr copper pvc insulated wire., mains with isi mark wp 2 x 2.5 sq.mm. 1100 v grade aluminium pvc insulated cable., mains with isi mark wp 2 x 4 sq.mm. 1100 v grade aluminium pvc insulated cable., mains with isi mark wp 2 x 6 sq. mm.1100 v. grade aluminium pvc insulated cable., retrofit t8 led 18 / 20 tube light., ceiling rose / batten holder /slanting holder /hanging cord switch / hanging bell push/ pendent holder bakelite base 6a., street light bracket made from 25 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., street light bracket made from 32 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., street light bracket made from 40 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., condenser 2.5 micro farad for ceiling fan., ceiling fan of 600mm. sweep complete, ceiling fan of 900mm. sweep complete, energy saving ceiling fan 230 v a.c. 50 cycles 1200mm complete, ceiling fan 230 v a.c. 50 cycles 1400 mm complete, double pole metal clad switch with hc type fuse 240v, 63a, triple pole metal clad switch and fuse 415v, 100a, spmcb 0.5a to 5a, c-series, spmcb 6a to 32a, b- series (for lighting), spmcb 40a to 63a, b- series (for lighting), tpmcb 6 a to 32a, 3 pole mccb upto 100a, 415v, with short circuit rating 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure, hc pattern porcelain fuse bridges with base & hc type fuse links 240v 16a erected on polished wooden block complete, hc pattern porcelain fuse bridges with base & hc type fuse links 240v 32a erected on polished wooden block complete, porcelain fuse bridges with base hc type fuse links 240v 63a erected on polished wooden block complete, porcelain fuse bridges with base hc type fuse links 415v 100a erected on polished wooden block complete, xlpe armoured cable 2 core 6 sq.mm. aluminium conductor with continuous 5.48 sq. mm, xlpe armoured cable 2 core 10 sq.mm. aluminium conductor with continuous 5.48 sq. mm, xlpe armoured cable 3 core 25 sq.mm. aluminium conductor, xlpe armoured cable 4 core 6 sq.mm. aluminium conductor, xlpe armoured cable 4 core 10 sq.mm. aluminium conductor, xlpe armoured cable 4 core 16 sq.mm. aluminium conductor, gi earth wire of high purity of different sizes used for earthing or any other purposes, providing pair of duly tested rubber hand gloves as per is:47705 suitable for working upto 22 kv supply complete., ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c., electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and (effective range upto 45 meter) bell on 250 v a.c.supply, electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete, double pole isolator only switch version of miniature circuit breaker of 40a, triple pole isolators only switch version of miniature circuit breaker of 63a, triple pole isolators only switch version of miniature circuit breaker of 100a, quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor., two pole power contactor 230 v, 12 a for time switch complete, two pole power contactor 230 v, 32 a for time switch complete, four pole power contactor 430 v, 16 a for time switch complete, four pole power contactor 430 v, 40 a for time switch complete, programmable digital almanac timer microcontroller based with real time clock to operate on de