Get complete information related to latest Fusible Plug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fusible Plug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fusible Plug Tenders.
Tender For supplying electrical materials and repair maintenance services for street lights and electrical works at. grampanchayat somatane - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunk
Tender For supply of empty dissolved acetylene cylinder, type three piece welded, to is 7312 as per following technical requirement (1) water capacity: 41 ltrs ( +3% , - 0% ) ( 2) hydrostatic stretch test pressure : 53 kgf / sq.cm (3) pneumatic leakage test pressure : 40 kgf / sq.cm (4) maximum working pressure at 15 degree celcious - 16 kgf /sq. cm , (5) gas capacity 07 kgs (6) outer dia : 258 mm ,(7) inner dia : 250 mm (8) wall thickness (nominal : 04 mm (9) lengthwithout valve 960 mm ( approx.) porous monolithic calcium silicate (11) porosity 90 to 92 % (12) crushing strength (min) : 22 kgf / sq.cm. (13 ) solvent : acetone ch3coch3, (14) empty weight : 55 kgs. (15) valve confirm to is: 3224, (16)fusibleplug as specified under gas cylinder rules 2004 & supported with manufacturers test certificate & certificate and approval from chief controller of explosives, govt. of india. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : procurement of clinker grinder fluid coupling and its spares at ntpckorba - comp assy,ghatge,coupling,11krg, fusibleplug,ghatge,coupling,11krg
Tender For tender for supply of spares for cooler gearbox cooler : - first stage pinion for cooler gear box h3 315, ration 60:1, sr no hg101768p make mas premilim transmission limited, first stage wheel for cooler gear box. 13 315, ration 601, se no hg101768p make mas premilim transmission limited, second stage pinion for cooler gear box h3 315, ration 60-1, sr no hg101765p make m/s premihim transmission limited., second stage wheel for cooler gear box hi 115, ration 601, sr no hg101768p make m/s premium transmission limited, third stage pinion for cooler gear box hi 115, bation 601, no hg101765p make mas premilim transmission limited, third stage wheel for cooler gear box he 115, bation 601, no hg101765p make m/s premilim transmission limited,, chitput shaft for cooler geaie box he hs, ration 60:1, sr no hg101768 make min premilim transmission limited,, multy disc part no 15 for fluid coupling model no fuli 17.75 make-ma premilim transmission limited, coupling, p/no. 23. for fluid coupling model no foi 17.75 make ma premilim transmission limited, bolt with nut part no. 28 of fou 17.75, make m/s premilis transmission limited, critput shaft coupling, part no. 26 gear box side of fou-17.75 make m/s premilim transmission limited, fusibleplug with washer p/n. 4143 for fluid cohipling model no fcu 17.75 make mas premium transmbabon limited, n, driving boss p/n 19 for fluid coupling model no fcu 17.75, make ma premium transmission limited, driving boss bolt nut p/n 21 & 2 for fluid coupling model no fo 17.75 make m/s premium transmission limited, complete coupling, model/type transmission lamited, fch 17.75 make m/s premilis, nut bolt and washer for resilient disc, part no 17 69 for fli coupling model no fcu 17,74, spherical coller p/n 77 for fluid coupling model no, fcu 17.75, make m/s premium transmission limited, resilient driving disc p/n 18 for fuid coupling model no fcu 17.3 make premhim transmission private limited
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For supply of aluminium brazing rod standard length , copper brazing rod standard length , petrol operated chain saw , crimping tool box , aluminium compression lugs and thimbles 300 sq.mm and 400 sq.mm , aluminium compression lugs and thimbles 240 sq.mm , t oil as per standard is 335