Tender For repair / maintenance of earthing, dg set, amf panel and mechanical laundry equipment along with certain other connected works at af station under ge (af) jamnagar no.2
Tender For repair / maint / replacement of electric wiring with fittings and fixtures, sub main wiring, dbs with earthing in md accn of nco academy at mil station dhana.
Tender For repair / maint / replacement of electric wiring with fittings and fixtures, sub main wiring, dbs with earthing in otm accn of nco academy at mil station dhana.
Tender For corrigendum : special repair/replacement of lt panels with acbs/mccbs and apfc panels and allied works at main power house and tech area sub stn and provn of pipeline and water tap for maintenance of earthing infrastructure at various placesat af station kalaikund
Tender For supply of rf analyzer or spectrum analyzer , sdr system complete usrp b210 and antennas and lna filter kit , rf signal generator , digital storage oscilloscope , logic analyzer , benchtop inductance capacitance resistance meter , smd rework station , esd work benches , precision esd toolkit and microscope , rf cables and adapters kit , vna calibration kit , high end desktop workstation for diagnostics mil grade , c two software , rf shielded enclosure faraday cage , bench power supply , building earth and earthing pit , centralised ups online system , mil grade electrical works , fire and smoke alarm system , rf safety devices , annual calibration year one
Tender For providing fixing and installation of fire material for fire station mc patiala. est cost rs. 1.33 lacs dt 22/23.06.2026 - xlpeinsulatedarmouredcables (loose):supply, laying and erection of aluminium conductor xlpe insulated pvc sheathed armoured and served cable 1100 voltsgradeasper is7098 (part-1)1988 tobe laid loose intheexistingtrenchorpipeas per pwd general specifications overall size 35sq.mm (4core) armoured(loose), mccbs (for panels & sheetenclosure):supply and erection of moulded case circuit breaker (panel mounting cubical type) in the existing cubical panel (confirm to iec:60947-2) having ics=100% icu, 100% neutral with spreader terminal links,extendedrotary handle and relevant pwd general specificationscompletewithg.i. bolts, nuts &connection on both sides of mccb with suitable size of thimbles etc:mccbfourpole200amp.,415volts, 25ka fixed magnetic and adjustable thermal setting, sheet metal bus barchambers (copper strips):supply and erection of sheet metal bus bar chamber (factory fabricated) duly powder coated on existing surface with required 4 nos.of tin plated copper bus bar strips of suitable length and cross sectional area mounted on dmc/ smc mouldsat sufficient distance, enclosure made of m.s. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmiumplated iron screws and of given overall dimensions and to be fixed with g.i.bolts and nuts/ ragbolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the engineer-in-charge at site:bus bar chamber 200amp., 415volts overall dimensions (455mm x 455mm x 150mm) nominal, supply and erection of heavy duty aluminium thimbles/lugs for cable endtermination duly crimped including making necessary connectionscompletely aluminium thimble cable core size 2535sq.mm, earthing with g.i.wire/ rope ing.i.pipe partly recessed and partly on surfacecomplete with 150 cm long 50mm dia.g.i. earthpipe (cutting threads and 36 nos. holes, 1cmdia. to makeamesh around the gi pipe) withg.i. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with20kg. charcoal & salt mixture etc., upto 8 metre in length (including boring & refilling). earthing with 8 s.w.g. (4mmdia.)g.i.wirein 15mm dia g.i. pipe with g.i. reducing socket 50mm x 15mm (upto 8metre in length), supply of mccb enclosure in all respects make lk/havells, supply of clump 1" g i, supply of screw 1.5"with gutty
Tender For corrigendum : repairing and maintenance of t/f and centrifuging of t/f oil and water level earthing of t/f at 33/11 kv sub station dangheda under edd deoband - fo|qr forj.k [k.m&nsocun ds vurxzr 33@11 ds0oh0 midsunz ma?ksmk ij lfkkfir 01 ux 05 ,e0oh0,0 ikoj ifjorzd o 01 ux 10 ,e0oh0,0 ikoj ifjorzd ds vk;wy dh lsuvªh¶;wftax djus] vffkzax o vkw;y fydst jksdus ls lanfhkzar dk;z
Tender For tender for prov. and fixing of equipment / material , design, erection, testing , commissioning for sop to jsv for inspection hut at cheel bangla chowari by prov. 11/0.4 kv 100 kva dtr along ht, lt line in es chowari-ii (u) esd chowari ed dalhousie - (a) supply part-11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 220kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(2 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 1 no., ms a.i.(50x50x6 mm), length: (950 mm) x 2 nos. of bed knee bracing, ms angle iron (50x50x6 mm), length : (2800 mm) x2 nos for transformer lt distribution box and g.o switch fixing assembly, g.i. wire for earthing, ms angle iron (50x50x6 mm), length : (450 mm)x1 nos for transformer lt distribution box and g.o switch fixing assembly, g.o. switch handle supporting: [c.i. (75x40x6mm), length: 460mm for transformer lt distribution box and g.o switch fixing assembly, g.o ab switch unit (11kv,400,663ka) tripple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class, discs insulator sets (comp. 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) i/c dead end clamps etc.), stay set complete, stay wire (7/3.15mm)( 10 kg per stay set), pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 100kva trf. as per specification, half clamp (m.s. flat 50x6), full clamps (m.s. flat 50x6), m. s. nuts & bolts off sizes (galvanised coated) [prefarably 16mm or more (with flat and spring washer), aluminium thimbles 300 mm sq., copper thimble 200 mm sq., danger plate, barbed wire (rec sp f 3/1981), lt cable 3-1/2 core-185mm sq., alluminium paint, prov.acsr, 6/1/3.35 mm, chain link fencing , angle iron, gate etc. for transfromer fencing, prov. transformer bed plinth for 1x400kva s/stn structure complete with cc 1:6:12 r.r. massonery & plastering etc. a/w chain link fencing, angle iron gate etc. for dtr fencing., lt switched caapcitors 36-kvar for 100 kva dtr, trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)., supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment)., fine dressing of the ground., spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately)., supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : screened through sieve of i.s. designation 20 mm, filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded)., providing and fixing korean grass turf superior qualitywith earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days