Get complete information related to latest Gas Regulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Regulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Regulator Tenders.
Tender For supply of pressure gauge for d.a./lpg gasregulator, working pressure 0-2.5 kg/cm2, dial size 2 inch, with minimum 6 months warranty and valid calibration certificate from a government-approved/nabl- accredited laboratory. make: weldstar/esab/wika/ramco/techno or equivalent reputed brand. [ warranty period: 6 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : 1-1/2" inch lpg control valve without actuator , 3/4" inch pilot lpg regulator inlet pressure 7 psi max outlet pressure range 18 to 40 mbar , 1/2" inch pressure balance ratio regulator for lpg service , uv sensor for lpg burner flame detection , dn40 main gasregulator for lpg service 5 bar max inlet pressure outlet pressure range 85-180 mbar , ignition electrode for heater , pilot burner without ignition rod , 1-1/2 inch solenoid valve normally closed auto reset fofc with cpi switch for lpg service 240 volts , dn25 pressure relief valve for lpg service
Tender For supply of screw compresor boq b b - air filter, part no. 39588777 , coolant filter element, part no. 39907175 , separator element, part no. 54595442 , blowdown solenoid valve, part no. 22124085 , kit high air temperature switch, part no. 37952264 , minimum pressure check valve, part no 70662416 , temperature sensor, part no 37952439 , v belt, part no 54524343 , gas spring, part no 39592951 , element thermo valve, part no 39441944 , inlet valve, part no 39840418 , shaft seal kit , part no 42486597 , kit unloader repair, part no 42385948 , belt, in 15 by 7 bar, part no. 54400726 , element separator, part no. 22388045 or 24121212 , element oil filter, part no. 39329602 , element air filter , part no. 88171913 , elbow 1by4 inch bspt x 6mm, part no. 54403266 , kit rebuild mpcv, part no. 18983262 , kit inlet valve rebuild sd, part no. 18983700 , switch pressure 7 bar in 7.5-15, part no. 70278999 or 23672744 * /bid number : gem/2026/b/7714185 + /dated: 26-06-2026 ' ' / bid document 1 / 24
Tender For annual repair m/o lwss karara 2nd phase at thana darogan in tehsil & district hamirpur (hp) (sh:- repair of 10 hp 6 stages bareazza make pump set no 1 providing and fixing of sluice vale spindle and check nut of 80mm and 100mm dia sluice valve) dnit no 02