Get complete information related to latest Gas Charging Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Charging Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Charging Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gascharging shall be paid and measured under respective item) complete all as specified and directed, supply & charginggas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gascharging shall be paid and measured under respective item) complete all as specified and directed, supply & charginggas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For bid to ras supply of replacement of rotary compressor , replacement of indoor blower fan motor , replacement of outdoor unit motor , replacement of pcb control unit , carrying out leak test and gascharging , shifting and reinstallation of outdoor units , sf 0.5 inch copper refrigerant pipe , sf 0.25 inch copper refrigerant pipe
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gascharging of ac , rewinding of burnt fan motor
Tender For supply of required materials & spare for rectification in pac units at haldia lpg import terminal - refrigerant gas r-407c, drier, filter, r410a, dml 305, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, nitrogen cylinder, 02 use, for gascharging, da use, for gascharging, multiple leakage rectification in pac outdoor units along with brazing and transportation of cylinders, display, small, icom, 180633g3r0 for air conditioning machine, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810, fan, axial, 230 vac, 700 w, 6000 (m ^ 3) / h 1300 rpm, 500 dia × 161 mm, ip54, rohs, control board, icom, large, 419661g2, for air conditioning machine, icom temper+humid.sensor 276810
Tender For corrigendum : cs/rmo/2026/2089-90/ac/washing - items, ac compressor 1-5 ton, ac compressor 2 ton, ac outdoor gas bal, ac indore fan motor, ac outdoor fan motor, ac condensers, ac gascharging, ac condenser outdoor mesh, connector ac, ac sensor indore, ac running capacitor, ac service charge, water cooler fan motor, water cooler compressor, water cooler condenser, water cooler mash, water cooler riley, water cooler over load, water cooler running capacitor, water cooler service charge, water cooler gas filling charge, washing machine spine timer, washing machine wash timer, washing machine wash motor, washing machine spine motor, washing machine bello, washing machine gear box, washing machine capacitor, washing machine service charge, refrigerator compressor, refrigerator rile, refrigerator overload, refrigerator thermometer, refrigerator senseor, refrigerator wall, refrigerator fan motor, refrigerator bimetal, refrigerator time, refrigerator pcv, refrigerator fuse, refrigerator door swath, refrigerator gas charge, refrigerator service charge, ac pcv, ac stand for spilit ac, ac stand for window ac, copper pipe for spilit ac per feet, copper pipe for window ac per feet, spilit and window ac remote
Tender For supply of cassette and split ac c c - cassette ac split ac , itc of ac , copper pipe, electrical cable, drain pipe , ms stand, indoor brackets, gascharging , ventilation work
Tender For annual maintenance contract of hvac and drinking water equipments at rmc parel mumbai 400 012 - deep freezers, capacity up to 500 itrs. (below 0 cto-75 °c), quantity - 8 nos. , refrigerators, capacity up to 400 ltrs. quantity -23 nos., , exhaust blower with ms casing on terrace (size & make - as per existing site), quantity - 2 nos., , fan coil units (above false ceiling/high wall mounting), capacity up-to-3tr, quantity - 12 nos., , servicing/breakdown repair of following electrical and water related equipments as per technical specifications., , refrigeration type water coolers (qty-4 nos.), , water purifier of various makes of barc based technology like jaltara/rupali/dolphin/nirmal aqua as per tender specifications. (qty-18, handset with dry cell for split or window air-conditioners, capacity-2.0tr, , metallic capacitor (approx. 50 microfarad), , replacement of rotary compressor (upto 2.0 tr capacity) of window & split type air conditioners with new compressor including dismantling of defective compressor, installation of new compressor, vacuuming, leak testing, gascharging, testing & commissionine as ner technical specifications., , supply, installation, testing & commissioning of following equipments as per technical specifications., , 3 stage water purifier based on barc developed technology, , fan coil units, upto 3 tr capacity, , fan filter units, 2 x 4 ft size, , plastic jar with float valve, , fabrication, supply and installation of ms structure as per technical specifications., , replacement of old candles of water purifier with following new ones as per technical specifications., , prefilter paper candle, , membrane candle, , carbon candle, , odour candle