Web Analytics Made Easy - StatCounter

Gas Detection System Tenders

Get complete information related to latest Gas Detection System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Detection System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Detection System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45486860 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply, installation and commissioning of fixed type/ wall mount hydrogen gas detection system make- msr electronic/ victory gas alarm co. or similar. detail technical specification is attached in annexure-i [ warranty period: 12 months after the date of delivery ] ]

CTN :45002663 Due date: 18 Jun, 202618 Jun, 2026 1.50 Crore
Tender For corrigendum : supply of gas detection system d d - total supply price including gst for group-01 , total supply price including gst for group-02 , total supply price including gst for group-03 , total transportation charges including gst for group-01 , total transportation charges including gst for group-02 , total transportation charges including gst for group-03 , supervision charges including gst for group-01 , supervision charges including gst for group-02 , supervision charges including gst for group-03

Central Government / Public Sector

CTN :45205428 Due date: 16 Jun, 202616 Jun, 2026 43.56 Lacs
Tender For corrigendum : annual rate contract for maintenance of fire and gas detection systems installed at wrpl vadinar base locations

Central Government / Public Sector

CTN :45392894 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For supply, fitment and successful proving of working of explosive gas detection and alarm system. one set of gas detection system, which consists of lel gas sensors (for explosive gases such as lpg/acetylene), smps, combined hoor and flasher, 3 core x 1.5 sq. mm armoured cable etc. and other materials required for successful detection of explosive gases and one portable diffusion type multi-gas detector to detect explosive gases and oxygen level concentration and other toxic gases. specification as per annexure-i. [ warranty period: 30 months after the date of delivery ] ]

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to

CTN :45282114 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For providing of custom bid for services - lpg gas detection system as per attached annexure a

Central Government And Public Sector

CTN :45034370 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : tender for supply of lockiconorganizationlockpinkiconsign in to unlock| send me onwhatsappmail|wishlistexport20days leftreagent kitsreagentsmicrobiology test kitsmedicinetesting equipment - phased array ultrasonic flaw detector 32-128 elements pr configuration with provision of additional 2 numbers of conventional ultrasonic channels , lithium iron battery pack rechargeable type minimum 70 wh having minimum operating time of 4 hours compatible for phased array ultrasonic flaw detector , external battery charger lithium iron battery pack compatible for phased array ultrasonic flaw detector , standard phased array probe , frequency-5.0 mhz , linear array , 64 elements , 0.5 mm pitch , total active aperture 32x10mm , 5 meter cable length , connector compatible for phased array ultrasonic flaw detector , standard phase array probe , frequency-7.5mhz , linear array , 16 elements , 0.5mm pitch , total active aperture-8mm x 10mm , 2.5 meter cable length , connector compatible to phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (26.67mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (48.26mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (73.03mm)axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (88.9mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (168.3mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (219.1mm)axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 55deg refracted angle in steel , shear wave , with ihc. the wedge should feature curvature matching pipe od (273.1mm) axial outside diameter (aod) for circumferential weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (26.67mm) circumferential outside diameter (cod) for axial weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array probe , normal scan , 60deg refracted angle in steel , shear wave , with ih. the wedge should feature curvature matching pipe od (48.26mm) circumferential outside diameter (cod) for axial weld inspection , compatible for phased array ultrasonic flaw detector , standard wedge for angle beam phased array pr

State Government

CTN :45074861 Due date: 21 May, 202621 May, 2026 5.00 Lacs
Tender For corrigendum : supply of t&p material for mulund division - combination plier with cutter, length 210 mm,, insulated screw driver 8mmx 200 mm, insulated screw driver 10mmx250 mm, neon tester 125mm, digital line tester, non-contact ac voltage detector tester pen 12v-1000v with led light, seamless rubber hand gloves, pair, free size test potential 30kv, working potential 26500v, seamless rubber hand gloves pair 380 mm long, test potential 25kv, working potential 17kv, lt hand gloves, class a first aid kit, tool box with tools, 20w led rechargeable torch (500mtr long beam light), ring double ended spanner set, clamp meter, meggar 5 kv, frp foldable discharge rod (ht) 22kv, frp do rod 11 kv ht, hydrometer

Central Government/Public Sector

CTN :45178029 Due date: 19 May, 202619 May, 2026 NA
Tender For invitation for pre-tender meet for fire and gas detection system of pdh pp plant with ethane and propane handling facilities at dahej, gujarat of pll.
 Loading, Please wait...

Connect us via What's Up