Web Analytics Made Easy - StatCounter

Gas Fitting Tenders

Get complete information related to latest Gas Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Fitting Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45732202 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply, termination installation, testing and commissioning of ventilation system in paint shop of lower parel workshop along with complete installation of industrial air blower with movable trolley, operating voltage 190v ac to 380 v ac, 50 hz, single/three phase supply, maximum power consumption shall be less than 600 watt, maximum speed of 400 rpm, air flow of 700 meter cube per minute, weight shallbe less than 60 kg and noise shall be less than 50db. size of blower shall not be more than 1500 mm diameter confirming to is 6272-1987 or latest all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt 1) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. materiat shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt. agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45737409 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of bimetallic terminal connector suitable for 25 mm dia, aluminium tubular bus bar to terminal pad of 3.3 kv isolator/ct with copper palm copper cu etp cw004l and aluminium barrel aluminium al 99.5cable connector temperature resilience, corrosion resistance confirming to is: 5561-1970 with maximum temperature rise of 90 degree elsius. material shall be confirmed to designation a6 of is: 61 7-1959. breakingresistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 35. (nabl certificate shall be submitted along with the offer) [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45743942 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply and end termination of over load current protection system along with full end termination suitable for overload and short circuit protection along with miniature circuit breaker distribution board with eight way mcb capacity 415 with busbar rating 200a v, c type rated sc capacity 10ka confirming tois: 13032:1991 latest with housing powder coating siemens grey-7035 with bimetallic terminal connector suitable for 16 dia aluminium tubular busbar for 32a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 16 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed todesignation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45604809 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply and end termination of over load current protection system along with full end termination suitable for overload and short circuit protection along with miniature circuit breaker distribution board with eight way mcb capacity 415 with busbar rating 200a v, c type rated sc capacity 10ka confirming tois: 13032:1991 latest with housing powder coating siemens grey-7035 with bimetallic terminal connector suitable for 16 dia aluminium tubular busbar for 32a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 16 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed todesignation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45615691 Due date: 02 Jul, 202602 Jul, 2026 5.65 Lacs
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35

Central Government And Public Sector

CTN :45617559 Due date: 03 Jul, 202603 Jul, 2026 5.63 Lacs
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

corporations/Associations/Others

CTN :45723719 Due date: 13 Jul, 202613 Jul, 2026 21.51 Lacs
Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarm system, fence alarm system covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser

Central Government And Public Sector

CTN :45716129 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For tender for supply of 70 sq mm,copper tubular terminal with following

CTN :45706500 Due date: 06 Jul, 202606 Jul, 2026 1.50 Lacs
Tender For supply of luminous eco volt neo inverter , top , ss combine , battery terminal , white board 4x4 , brown paint , black paint , white paint , grass cutting wire , metal iron cutting , blade 4inch , welding rod no 10 , welding rod no 12 , drilling steel screw 1inch , drilling steel screw 2inch , drilling steel screw 2.5inch , tubular box spanner 8mm , heavy welding helmet , welding glass , drill bit set , protection glass , garden pipe 30mtr , heavy duty grass edge cutter , flex with frame 3x4 , buffer bubble roll , green net , led 43inch 4k smart tv , envelope cover 7x5 , envelope cover 11x5 , envelope cover 16x12 , envelope cover 9x4 , envelope cover laminated green 11x5 , envelope cover laminated green 16x12 , calculator , iron nails , flex 6x5
 Loading, Please wait...

Connect us via What's Up