Get complete information related to latest Gas Refrigerant Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gas Refrigerant Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gas Refrigerant Tenders.
Tender For design, supply, installation, testing and commissioning internal piping (ip) for piped natural gas (png) as per pngrb guidelines and as per specification mech/mh/png/4200/gm dated 08.06.2026
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerantgas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gasrefrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerantgas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gasrefrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For tender for appointment of ca firm for certification of gas quantities on quarterly submission to ppac and certification of quantities consumed under cng(t) and png(d) and booked under uft zone 1 for submission to pngrb
Tender For providing of custom bid for services - hirring of services for calibration of png inc custody meters drs reconciliation meters and domestic meters for calibration at vendor works to improve overall gas measurement uncertainty and confidence in metering at lucknow..,custom bid for services - hirring of services for calibration of png inc custody meters drs reconciliation meters and domestic meters for calibration at vendor works to improve overall gas measurement uncertainty and confidence in metering at lucknow..,custom bid for services - hirring of services for calibration of png inc custody meters drs reconciliation meters and domestic meters for calibration at vendor works to improve overall gas measurement uncertainty and confidence in metering at lucknow..,custom bid for services - hirring of services for calibration of png inc custody meters drs reconciliation meters and domestic meters for calibration at vendor works to improve overall gas measurement uncertainty and confidence in metering at lucknow..
Tender For procurement of spares for stahl make field hmi system installed in gail pata -ministry of petroleum & natural gas vide notification no. fp20013/2/2017-fp-png-part(4) (e-41432) dated 26.04.2022 hasnotified that public procurement
Tender For design, supply, installation, testing and commissioning internal piping (ip) for piped natural gas (png) as per pngrb guidelines and as per specification mech/mh/png/4200/gm dated 08.06.2026
Tender For corrigendum : providing of custom bid for services - rate contract for meter reading and bill distribution for png connections of iocl cgd gas group a (gas under jaipur and patna cgd offices,custom bid for services - rate contract for meter reading and bill distribution for png connections of iocl cgd gas group a (gas under jaipur and patna cgd offices,custom bid for services - rate contract for meter reading and bill distribution for png connections of iocl cgd gas group b (gas under chennai cgd office),custom bid for services - rate contract for meter reading and bill distribution for png connections of iocl cgd gas group b (gas under chennai cgd office)
Tender For corrigendum : bid document for bid document for png control room manpower service contract for kanpur including unnao for city gas distribution project of m/s. central u. p. gas limited, for the period of 03 years
Tender For supply of gasrefrigerant r 134a alongwith non returnable gas cylinder , gasrefrigerant r 407c for air dyryer alonwith non returnable cylinder , gasrefrigerant r-32 alongwith non returnable gas cylinder , gasrefrigerant r 410a alongwith non returnable gas cylinder , gasrefrigerant r 404a along with non returnable gas cylinder , gasrefrigerant suva 95 alongwith non returnable cylinder